이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Randomized Prospective Trial on the Cost-Effectiveness of Photon-Counting CT Versus Energy-Integrating Detector CT in Suspected Chronic Coronary Syndrome (COST-PCCT-CCS)

2026년 9월 15일 업데이트: Antonio Esposito, IRCCS San Raffaele

Coronary artery disease (CAD) is a leading cause of morbidity and mortality worldwide. Coronary computed tomography angiography (CCTA) is recommended as a first-line imaging test in patients with suspected obstructive CAD. However, conventional energy-integrating detector CT (EID-CT) has limited specificity, particularly in patients with a high coronary calcification burden, because blooming and beam-hardening artifacts can lead to stenosis overestimation and potentially unnecessary downstream diagnostic testing or invasive coronary angiography (ICA). Photon-counting detector CT (PCD-CT) provides higher spatial resolution, reduced electronic noise, and decreased blooming artifacts compared with conventional EID-CT. These technical advantages may improve the diagnostic assessment of coronary stenoses, reduce false-positive findings, and consequently decrease the need for additional functional testing and unnecessary ICA. Improved diagnostic accuracy may also influence treatment decisions, patient outcomes, and healthcare resource utilization.

This study aims to compare PCD-CT and EID-CT CCTA for the detection and quantification of CAD in a real-world clinical setting. In addition to diagnostic performance, the study will evaluate the impact of the two imaging strategies on subsequent diagnostic and therapeutic management, healthcare resource utilization, costs, and clinical outcomes. Patients will be followed from the date of the index CCTA examination for up to two years. Healthcare costs will be estimated using national and regional reimbursement tariffs of the Italian public healthcare system.

연구 개요

상세 설명

Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality worldwide. Coronary computed tomography angiography (CCTA) is the first-line imaging test for patients with suspected obstructive CAD. However, its main limitation is the relatively low and variable specificity and positive predictive value across different studies, especially in patients with high calcified coronary plaque burden due to blooming and beam-hardening artifacts that can lead to the overestimation of the degree of coronary artery stenosis, reduced specificity, and, consequently, increased rate of downstream functional imaging tests or diagnostic invasive coronary angiography (ICA). Photon-Counting Detector-Computed Tomography (PCD-CT) represents an important evolution in the CT technology introduced in the clinical practice in the last years, but still with a limited diffusion due to the high purchase cost of the scanners. In the context of CAD evaluation, the two modalities differ in spatial resolution, blooming artifacts, and electronic noise levels, representing distinct technical approaches to diagnostic imaging accuracy. Recent studies demonstrate that these technical advantages may translate into a higher diagnostic accuracy of PCD-CT in differentiating functional significant stenosis from non-significant stenosis, with a lower rate of false positive results and higher overall diagnostic accuracy. This increase in diagnostic accuracy with reduction in false positive results may be associated to a reduction in downstream functional tests performed after a PCD-CT CCTA compared with an EID-CT CCTA, as well as a decrease in unnecessary invasive coronary angiographies resulting from false-positive CCTA findings. Moreover, a more precise diagnosis may also translate into more appropriate treatment decisions and potential prognostic benefits. These potential advantages may ultimately lead to a reduction in downstream healthcare expenditures when using PCD-CT CCTA. However, the impact of these differences on clinical decision-making and healthcare resource utilization remains to be fully established in real-world settings. Thus, the investigator proposes to compare the diagnostic performance of PCD-CT performed with a NAEOTOM Alpha photon-counting CT scanner (Siemens Healthineers, Germany) and EID-CT performed with a SOMATOM Definition Flash (Siemens Healthineers, Germany) in the identification and quantification of CAD. Moreover, the investigator aims to assess the cost-effectiveness and the prognostic impact of PCD-CT compared to EID-CT in CAD diagnosis and management according to 2024 ESC Guidelines, collecting all index data related to the patients' clinical history from the day of the CCTA examination up to two years afterward, and estimating healthcare costs according to the national and regional reimbursement tariffs of the public health system for all healthcare services delivered.

연구 유형

중재적

등록 (추정된)

630

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 장소

    • Milano
      • Milan, Milano, 이탈리아, 20132
        • Advanced Imaging for Personalized Medicine/Radiologia DiMer

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • clinical indication to perform CCTA for CAD assessment according to 2024 ESC Guidelines

Exclusion Criteria:

  • Refusal to participate in the study
  • Age <18 years old
  • Severe reduction in eGFR (<30 mL/min)

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 특수 증상
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 하나의

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: Energy Integrating Detector CT (EID-CT)

Participants undergo CCTA performed using Energy Integrating Detector CT (EID-CT).

Patients undergoing CCTA on EID-CT

활성 비교기: Photon Counting Detector CT (PCD-CT)

Participants undergo CCTA performed using Photon Counting CT (PCD-CT).

Undergoing CCTA with PCD-CT

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
Positive predictive value (PPV) of CCTA for the detection of obstructive CAD, using ICA as the reference standard
기간: Baseline diagnostic workup

To compare the positive predictive value (PPV) of coronary computed tomography angiography (CCTA) performed using PCD-CT versus EID-CT, when used according to the clinical indications defined by the 2024 ESC Guidelines for the management of chronic coronary syndromes.

Baseline diagnostic workup

2차 결과 측정

결과 측정
측정값 설명
기간
To evaluate the cost effectiveness comparing two CT platforms implemented in routine clinical practice in the diagnostic workup of suspected chronic coronary syndromes, according to the 2024 ESC Guidelines.
기간: Up to 3 years after CCTA examination

Incremental cost-effectiveness ratio (ICER), expressed as cost per correctly diagnosed patient based on healthcare resource utilization and diagnostic outcomes. For the calculation of the ICER true negative will be considered all patients with negative CCTA without events (MACEs) over the 3 years FU.

Up to 3 years after CCTA examination

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

스폰서

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2026년 9월 1일

기본 완료 (추정된)

2027년 9월 30일

연구 완료 (추정된)

2029년 9월 30일

연구 등록 날짜

최초 제출

2026년 9월 9일

QC 기준을 충족하는 최초 제출

2026년 9월 15일

처음 게시됨 (실제)

2026년 9월 21일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 9월 21일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 9월 15일

마지막으로 확인됨

2026년 9월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

IPD 계획 설명

Only data used in the results publication will be shared under request

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다