此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Randomized Prospective Trial on the Cost-Effectiveness of Photon-Counting CT Versus Energy-Integrating Detector CT in Suspected Chronic Coronary Syndrome (COST-PCCT-CCS)

2026年11月5日 更新者:Antonio Esposito、IRCCS San Raffaele

Coronary artery disease (CAD) is a leading cause of morbidity and mortality worldwide. Coronary computed tomography angiography (CCTA) is recommended as a first-line imaging test in patients with suspected obstructive CAD. However, conventional energy-integrating detector CT (EID-CT) has limited specificity, particularly in patients with a high coronary calcification burden, because blooming and beam-hardening artifacts can lead to stenosis overestimation and potentially unnecessary downstream diagnostic testing or invasive coronary angiography (ICA). Photon-counting detector CT (PCD-CT) provides higher spatial resolution, reduced electronic noise, and decreased blooming artifacts compared with conventional EID-CT. These technical advantages may improve the diagnostic assessment of coronary stenoses, reduce false-positive findings, and consequently decrease the need for additional functional testing and unnecessary ICA. Improved diagnostic accuracy may also influence treatment decisions, patient outcomes, and healthcare resource utilization.

This study aims to compare PCD-CT and EID-CT CCTA for the detection and quantification of CAD in a real-world clinical setting. In addition to diagnostic performance, the study will evaluate the impact of the two imaging strategies on subsequent diagnostic and therapeutic management, healthcare resource utilization, costs, and clinical outcomes. Patients will be followed from the date of the index CCTA examination for up to two years. Healthcare costs will be estimated using national and regional reimbursement tariffs of the Italian public healthcare system.

研究概览

详细说明

Coronary artery disease (CAD) is one of the leading causes of morbidity and mortality worldwide. Coronary computed tomography angiography (CCTA) is the first-line imaging test for patients with suspected obstructive CAD. However, its main limitation is the relatively low and variable specificity and positive predictive value across different studies, especially in patients with high calcified coronary plaque burden due to blooming and beam-hardening artifacts that can lead to the overestimation of the degree of coronary artery stenosis, reduced specificity, and, consequently, increased rate of downstream functional imaging tests or diagnostic invasive coronary angiography (ICA). Photon-Counting Detector-Computed Tomography (PCD-CT) represents an important evolution in the CT technology introduced in the clinical practice in the last years, but still with a limited diffusion due to the high purchase cost of the scanners. In the context of CAD evaluation, the two modalities differ in spatial resolution, blooming artifacts, and electronic noise levels, representing distinct technical approaches to diagnostic imaging accuracy. Recent studies demonstrate that these technical advantages may translate into a higher diagnostic accuracy of PCD-CT in differentiating functional significant stenosis from non-significant stenosis, with a lower rate of false positive results and higher overall diagnostic accuracy. This increase in diagnostic accuracy with reduction in false positive results may be associated to a reduction in downstream functional tests performed after a PCD-CT CCTA compared with an EID-CT CCTA, as well as a decrease in unnecessary invasive coronary angiographies resulting from false-positive CCTA findings. Moreover, a more precise diagnosis may also translate into more appropriate treatment decisions and potential prognostic benefits. These potential advantages may ultimately lead to a reduction in downstream healthcare expenditures when using PCD-CT CCTA. However, the impact of these differences on clinical decision-making and healthcare resource utilization remains to be fully established in real-world settings. Thus, the investigator proposes to compare the diagnostic performance of PCD-CT performed with a NAEOTOM Alpha photon-counting CT scanner (Siemens Healthineers, Germany) and EID-CT performed with a SOMATOM Definition Flash (Siemens Healthineers, Germany) in the identification and quantification of CAD. Moreover, the investigator aims to assess the cost-effectiveness and the prognostic impact of PCD-CT compared to EID-CT in CAD diagnosis and management according to 2024 ESC Guidelines, collecting all index data related to the patients' clinical history from the day of the CCTA examination up to two years afterward, and estimating healthcare costs according to the national and regional reimbursement tariffs of the public health system for all healthcare services delivered.

研究类型

介入性

注册 (估计的)

630

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

    • Milano
      • Milan、Milano、意大利、20132
        • 招聘中
        • Advanced Imaging for Personalized Medicine/Radiologia DiMer
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • clinical indication to perform CCTA for CAD assessment according to 2024 ESC Guidelines

Exclusion Criteria:

  • Refusal to participate in the study
  • Age <18 years old
  • Severe reduction in eGFR (<30 mL/min)

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:诊断
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
有源比较器:Energy Integrating Detector CT (EID-CT)

Participants undergo CCTA performed using Energy Integrating Detector CT (EID-CT).

Patients undergoing CCTA on EID-CT

有源比较器:Photon Counting Detector CT (PCD-CT)

Participants undergo CCTA performed using Photon Counting CT (PCD-CT).

Undergoing CCTA with PCD-CT

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Positive predictive value (PPV) of CCTA for the detection of obstructive CAD, using ICA as the reference standard
大体时间:Baseline diagnostic workup

To compare the positive predictive value (PPV) of coronary computed tomography angiography (CCTA) performed using PCD-CT versus EID-CT, when used according to the clinical indications defined by the 2024 ESC Guidelines for the management of chronic coronary syndromes.

Baseline diagnostic workup

次要结果测量

结果测量
措施说明
大体时间
To evaluate the cost effectiveness comparing two CT platforms implemented in routine clinical practice in the diagnostic workup of suspected chronic coronary syndromes, according to the 2024 ESC Guidelines.
大体时间:Up to 3 years after CCTA examination

Incremental cost-effectiveness ratio (ICER), expressed as cost per correctly diagnosed patient based on healthcare resource utilization and diagnostic outcomes. For the calculation of the ICER true negative will be considered all patients with negative CCTA without events (MACEs) over the 3 years FU.

Up to 3 years after CCTA examination

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年9月1日

初级完成 (估计的)

2027年9月30日

研究完成 (估计的)

2029年9月30日

研究注册日期

首次提交

2026年9月9日

首先提交符合 QC 标准的

2026年9月15日

首次发布 (实际的)

2026年9月21日

研究记录更新

最后更新发布 (实际的)

2026年11月6日

上次提交的符合 QC 标准的更新

2026年11月5日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Only data used in the results publication will be shared under request

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅