이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Custom-Made Titanium Plates Versus Custom-Made Polyether Ether Ketone (PEEK) Plates

2026년 10월 6일 업데이트: Mansoura University

Custom-Made Titanium Plates Versus Custom-Made Polyether Ether Ketone (PEEK) Plates for Fixation of Mandibular Fractures

Mandibular fractures represent a significant portion of maxillofacial trauma, primarily resulting from motor vehicle accidents, interpersonal violence, and sports-related injuries. Achieving successful treatment requires accurate anatomical reduction, stable internal fixation, and restoration of pre-traumatic occlusion and masticatory function . Open reduction and internal fixation (ORIF) using titanium miniplates has long served as the gold standard for mandibular fracture management due to their superior mechanical strength, excellent biocompatibility, and proven structural reliability .

Despite their widespread clinical adoption, conventional titanium plates present notable drawbacks. Their high elastic modulus compared to human cortical bone often leads to stress shielding, which can impede normal bone healing and cause local osteopenia .Additionally, titanium hardware can cause temperature sensitivity, scatter artifacts on computed tomography (CT) and magnetic resonance imaging (MRI) scans, and may necessitate secondary surgical removal due to palpability or infection .

To address these limitations, Polyether Ether Ketone (PEEK)-a high-performance thermoplastic polymer has emerged as a promising alternative biomaterial in maxillofacial surgery. PEEK exhibits an elastic modulus close to natural bone, thereby reducing stress shielding and promoting physiological strain distribution during fracture healing. Furthermore, PEEK is radiolucent, non-magnetic, and chemically inert, allowing artifact-free postoperative radiologic assessment .

With advancements in digital dentistry, computer-aided design and computer-aided manufacturing (CAD/CAM) alongside 3D printing have enabled the fabrication of patient-specific, custom-made implants. Custom-made titanium and PEEK plates eliminate the need for intraoperative manual bending, significantly reducing surgical time, improving contour accuracy, and enhancing mechanical stability across the fracture site . While custom-made titanium provides rigid fixation suitable for high-load zones, custom-made PEEK implants offer an biomechanically compatible and artifact-free alternative.

However, direct comparative clinical and biomechanical evaluations between custom-made titanium and custom-made PEEK plates for mandibular fracture fixation remain limited. Therefore, this study aimed to evaluate and compare the clinical outcome, stability, and surgical efficiency of custom-made titanium versus custom-made PEEK plates in the fixation of mandibular fractures.

연구 개요

상세 설명

Maxillofacial trauma is the most common cause of facial injuries resulting from various causes such as road traffic accidents, accidental falls, assaults, industrial mishaps, sports injuries and firearm injuries. The severity and pattern of maxillofacial trauma depend on the anatomic site, magnitude, and the direction of the force delivered to the face.

Reconstruction of facial bones following traumatic events represents one of the greatest challenges to maxillofacial surgeons. The role of the mandible is crucial in maintaining facial esthetics and functional occlusion. Due to its prominence and mobility, mandibular fractures represent the most common facial fractures, accounting for approximately 59% of all maxillofacial fractures.

Treatment modalities for mandibular fractures include closed reduction with intermaxillary fixation, open reduction with wire osteosynthesis and open reduction with rigid fixation. With modern surgical advances, modalities for the treatment of mandibular fracture depending on scientific facilities have been directed to facilitate the need of early, preferably and immediate mobilization in order to reduce the need of maxillomandibular fixation (MMF).

Whereas MMF is to blame for impairing the oral hygiene, masticatory efficiency and mouth opening besides it causes pain, phonetic disturbance and weight loss. Mandibular fractures are ideally treated with open reduction and internal fixation by an intraoral or extraoral approach. Direct bone contact between the fracture segments supports primary bone healing, that results in earlier bone regrowth and stability across the fracture site.

Nowadays, computers are being extensively used not only for diagnosis but also for designing surgical procedures in the craniomaxillofacial field. Advances in virtual surgery, 3D printing and milling techniques have significantly increased surgical precision and efficiency. These advances can be utilized alongside digital imaging techniques like computerized tomography (CT) to generate custom-made plates specifically tailored for each fracture. This can serve to shorten the operation time, eliminate the need to remove the plates and improve fixation system stability. The possibility of generating a three-dimensional model from CT scans was first mentioned in 19870.

Many materials can be employed in the process of manufacturing these custom-made plates like titanium, which is the most common conventional used type and Polyether ether ketone (PEEK) being a recent alternative.

PEEK is a linear semi-crystalline poly-aromatic polymer which has dimensional properties close to that of living bone in terms of strength and stiffness. The major beneficial property of PEEK is its lower Young's modulus of elasticity which is close to that of the cortical bone and therefore, it is likely to eliminate the major problem encountered with titanium plating system which is the stress shielding phenomenon. It is highly durable, resists a high degree of temperature greater than 300 degrees Celsius and can be used without adverse tissue effects. This study aims to evaluate the use of custom-made titanium plates versus PEEK plates in the treatment of mandibular fractures.

The null hypothesis states that there is no significant difference in clinical and radiographic outcomes between custom-made titanium plates and custom-made PEEK plates for fixation of mandibular fractures.

연구 유형

중재적

등록 (추정된)

32

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

연구 장소

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, 이집트, 35516
        • 모병
        • Mansoura University, Faculty of Dentistry

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 (성인)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Patients age ranging from 18 to 50 years.
  • Unilateral and/or bilateral simple or compound fractures of the mandibular symphysis, parasymphysis or body regions that are displaced and require open reduction with internal fixation.
  • The fractures must be recent, having occurred no longer than 10 days prior to the surgical treatment.
  • Healthy patients who are classified according to the American Society of Anesthesiologists (ASA) physical status classification as class I.

Exclusion Criteria:

  • Patients suffer from pathological fractures.
  • Comminuted and infected fractures.
  • Fracture of the atrophic edentulous ridge
  • Old mandibular fractures (more than 10 days).
  • Patients with ASA classes II, III, IV, and V.

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 없음(오픈 라벨)

무기와 개입

참가자 그룹 / 팔
개입 / 치료
실험적: Custom-Made Titanium Plate

Custom-Made Titanium Plate for Fixation of Mandibular Fractures

Custom-made titanium plate used for fixation of mandibular fractures.

실험적: Custom-Made PEEK Plate

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
number of patients with adequate reduction of the fractured segment
기간: immediately and 6 months after the surgery consequently

will be determined by an assessment of the inferior border of the mandible as follows:

  1. Excellent reduction: whenever alignment of the inferior border of mandible will be maintained across the fracture line.
  2. Good reduction: if a discrepancy of 1-3 mm is noted.
  3. Fair reduction: if a discrepancy of 3-5mm is noted.
  4. Poor reduction: if the discrepancy is > 5 mm.
immediately and 6 months after the surgery consequently

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

수사관

  • 수석 연구원: Aya ali Elsies, assistant lecturer, Faculty of Dentistry, Mansoura University

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 9월 24일

기본 완료 (추정된)

2027년 3월 24일

연구 완료 (추정된)

2028년 9월 24일

연구 등록 날짜

최초 제출

2026년 9월 23일

QC 기준을 충족하는 최초 제출

2026년 9월 23일

처음 게시됨 (실제)

2026년 9월 30일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 10월 9일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 10월 6일

마지막으로 확인됨

2026년 10월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

아니요

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .

구독하다