Ta strona została przetłumaczona automatycznie i dokładność tłumaczenia nie jest gwarantowana. Proszę odnieść się do angielska wersja za tekst źródłowy.

Custom-Made Titanium Plates Versus Custom-Made Polyether Ether Ketone (PEEK) Plates

6 października 2026 zaktualizowane przez: Mansoura University

Custom-Made Titanium Plates Versus Custom-Made Polyether Ether Ketone (PEEK) Plates for Fixation of Mandibular Fractures

Mandibular fractures represent a significant portion of maxillofacial trauma, primarily resulting from motor vehicle accidents, interpersonal violence, and sports-related injuries. Achieving successful treatment requires accurate anatomical reduction, stable internal fixation, and restoration of pre-traumatic occlusion and masticatory function . Open reduction and internal fixation (ORIF) using titanium miniplates has long served as the gold standard for mandibular fracture management due to their superior mechanical strength, excellent biocompatibility, and proven structural reliability .

Despite their widespread clinical adoption, conventional titanium plates present notable drawbacks. Their high elastic modulus compared to human cortical bone often leads to stress shielding, which can impede normal bone healing and cause local osteopenia .Additionally, titanium hardware can cause temperature sensitivity, scatter artifacts on computed tomography (CT) and magnetic resonance imaging (MRI) scans, and may necessitate secondary surgical removal due to palpability or infection .

To address these limitations, Polyether Ether Ketone (PEEK)-a high-performance thermoplastic polymer has emerged as a promising alternative biomaterial in maxillofacial surgery. PEEK exhibits an elastic modulus close to natural bone, thereby reducing stress shielding and promoting physiological strain distribution during fracture healing. Furthermore, PEEK is radiolucent, non-magnetic, and chemically inert, allowing artifact-free postoperative radiologic assessment .

With advancements in digital dentistry, computer-aided design and computer-aided manufacturing (CAD/CAM) alongside 3D printing have enabled the fabrication of patient-specific, custom-made implants. Custom-made titanium and PEEK plates eliminate the need for intraoperative manual bending, significantly reducing surgical time, improving contour accuracy, and enhancing mechanical stability across the fracture site . While custom-made titanium provides rigid fixation suitable for high-load zones, custom-made PEEK implants offer an biomechanically compatible and artifact-free alternative.

However, direct comparative clinical and biomechanical evaluations between custom-made titanium and custom-made PEEK plates for mandibular fracture fixation remain limited. Therefore, this study aimed to evaluate and compare the clinical outcome, stability, and surgical efficiency of custom-made titanium versus custom-made PEEK plates in the fixation of mandibular fractures.

Przegląd badań

Szczegółowy opis

Maxillofacial trauma is the most common cause of facial injuries resulting from various causes such as road traffic accidents, accidental falls, assaults, industrial mishaps, sports injuries and firearm injuries. The severity and pattern of maxillofacial trauma depend on the anatomic site, magnitude, and the direction of the force delivered to the face.

Reconstruction of facial bones following traumatic events represents one of the greatest challenges to maxillofacial surgeons. The role of the mandible is crucial in maintaining facial esthetics and functional occlusion. Due to its prominence and mobility, mandibular fractures represent the most common facial fractures, accounting for approximately 59% of all maxillofacial fractures.

Treatment modalities for mandibular fractures include closed reduction with intermaxillary fixation, open reduction with wire osteosynthesis and open reduction with rigid fixation. With modern surgical advances, modalities for the treatment of mandibular fracture depending on scientific facilities have been directed to facilitate the need of early, preferably and immediate mobilization in order to reduce the need of maxillomandibular fixation (MMF).

Whereas MMF is to blame for impairing the oral hygiene, masticatory efficiency and mouth opening besides it causes pain, phonetic disturbance and weight loss. Mandibular fractures are ideally treated with open reduction and internal fixation by an intraoral or extraoral approach. Direct bone contact between the fracture segments supports primary bone healing, that results in earlier bone regrowth and stability across the fracture site.

Nowadays, computers are being extensively used not only for diagnosis but also for designing surgical procedures in the craniomaxillofacial field. Advances in virtual surgery, 3D printing and milling techniques have significantly increased surgical precision and efficiency. These advances can be utilized alongside digital imaging techniques like computerized tomography (CT) to generate custom-made plates specifically tailored for each fracture. This can serve to shorten the operation time, eliminate the need to remove the plates and improve fixation system stability. The possibility of generating a three-dimensional model from CT scans was first mentioned in 19870.

Many materials can be employed in the process of manufacturing these custom-made plates like titanium, which is the most common conventional used type and Polyether ether ketone (PEEK) being a recent alternative.

PEEK is a linear semi-crystalline poly-aromatic polymer which has dimensional properties close to that of living bone in terms of strength and stiffness. The major beneficial property of PEEK is its lower Young's modulus of elasticity which is close to that of the cortical bone and therefore, it is likely to eliminate the major problem encountered with titanium plating system which is the stress shielding phenomenon. It is highly durable, resists a high degree of temperature greater than 300 degrees Celsius and can be used without adverse tissue effects. This study aims to evaluate the use of custom-made titanium plates versus PEEK plates in the treatment of mandibular fractures.

The null hypothesis states that there is no significant difference in clinical and radiographic outcomes between custom-made titanium plates and custom-made PEEK plates for fixation of mandibular fractures.

Typ studiów

Interwencyjne

Zapisy (Szacowany)

32

Faza

  • Nie dotyczy

Kontakty i lokalizacje

Ta sekcja zawiera dane kontaktowe osób prowadzących badanie oraz informacje o tym, gdzie badanie jest przeprowadzane.

Kontakt w sprawie studiów

Kopia zapasowa kontaktu do badania

Lokalizacje studiów

    • Dakahlia Governorate
      • Al Mansurah, Dakahlia Governorate, Egipt, 35516
        • Rekrutacyjny
        • Mansoura University, Faculty of Dentistry

Kryteria uczestnictwa

Badacze szukają osób, które pasują do określonego opisu, zwanego kryteriami kwalifikacyjnymi. Niektóre przykłady tych kryteriów to ogólny stan zdrowia danej osoby lub wcześniejsze leczenie.

Kryteria kwalifikacji

Wiek uprawniający do nauki

18 lat do 50 lat (Dorosły)

Akceptuje zdrowych ochotników

Nie

Płeć kwalifikująca się do nauki

Wszystko

Opis

Inclusion Criteria:

  • Patients age ranging from 18 to 50 years.
  • Unilateral and/or bilateral simple or compound fractures of the mandibular symphysis, parasymphysis or body regions that are displaced and require open reduction with internal fixation.
  • The fractures must be recent, having occurred no longer than 10 days prior to the surgical treatment.
  • Healthy patients who are classified according to the American Society of Anesthesiologists (ASA) physical status classification as class I.

Exclusion Criteria:

  • Patients suffer from pathological fractures.
  • Comminuted and infected fractures.
  • Fracture of the atrophic edentulous ridge
  • Old mandibular fractures (more than 10 days).
  • Patients with ASA classes II, III, IV, and V.

Plan studiów

Ta sekcja zawiera szczegółowe informacje na temat planu badania, w tym sposób zaprojektowania badania i jego pomiary.

Jak projektuje się badanie?

Szczegóły projektu

  • Główny cel: Leczenie
  • Przydział: Randomizowane
  • Model interwencyjny: Przydział równoległy
  • Maskowanie: Brak (otwarta etykieta)

Broń i interwencje

Grupa uczestników / Arm
Interwencja / Leczenie
Eksperymentalny: Custom-Made Titanium Plate

Custom-Made Titanium Plate for Fixation of Mandibular Fractures

Custom-made titanium plate used for fixation of mandibular fractures.

Eksperymentalny: Custom-Made PEEK Plate

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

Custom-made polyether ether ketone (PEEK) plate used for fixation of mandibular fractures.

Co mierzy badanie?

Podstawowe miary wyniku

Miara wyniku
Opis środka
Ramy czasowe
number of patients with adequate reduction of the fractured segment
Ramy czasowe: immediately and 6 months after the surgery consequently

will be determined by an assessment of the inferior border of the mandible as follows:

  1. Excellent reduction: whenever alignment of the inferior border of mandible will be maintained across the fracture line.
  2. Good reduction: if a discrepancy of 1-3 mm is noted.
  3. Fair reduction: if a discrepancy of 3-5mm is noted.
  4. Poor reduction: if the discrepancy is > 5 mm.
immediately and 6 months after the surgery consequently

Współpracownicy i badacze

Tutaj znajdziesz osoby i organizacje zaangażowane w to badanie.

Śledczy

  • Główny śledczy: Aya ali Elsies, assistant lecturer, Faculty of Dentistry, Mansoura University

Daty zapisu na studia

Daty te śledzą postęp w przesyłaniu rekordów badań i podsumowań wyników do ClinicalTrials.gov. Zapisy badań i zgłoszone wyniki są przeglądane przez National Library of Medicine (NLM), aby upewnić się, że spełniają określone standardy kontroli jakości, zanim zostaną opublikowane na publicznej stronie internetowej.

Główne daty studiów

Rozpoczęcie studiów (Szacowany)

24 września 2026

Zakończenie podstawowe (Szacowany)

24 marca 2027

Ukończenie studiów (Szacowany)

24 września 2028

Daty rejestracji na studia

Pierwszy przesłany

23 września 2026

Pierwszy przesłany, który spełnia kryteria kontroli jakości

23 września 2026

Pierwszy wysłany (Rzeczywisty)

30 września 2026

Aktualizacje rekordów badań

Ostatnia wysłana aktualizacja (Rzeczywisty)

9 października 2026

Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości

6 października 2026

Ostatnia weryfikacja

1 października 2026

Więcej informacji

Terminy związane z tym badaniem

Plan dla danych uczestnika indywidualnego (IPD)

Planujesz udostępniać dane poszczególnych uczestników (IPD)?

NIE

Informacje o lekach i urządzeniach, dokumenty badawcze

Bada produkt leczniczy regulowany przez amerykańską FDA

Nie

Bada produkt urządzenia regulowany przez amerykańską FDA

Nie

produkt wyprodukowany i wyeksportowany z USA

Nie

Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .

Subskrybuj