Evaluation of a Dry Powder Aerosol Dispersion Mechanism by Radiolabeling Techniques (DPI)
2017年1月20日 更新者:William Bennett, PhD、University of North Carolina, Chapel Hill
The primary objective is to admix a radiolabel with albuterol sulphate for incorporation into the Handihaler® device for inhalation studies.
This will allow for the investigators to determine the regional lung deposition of drug inhaled from the standard Handihaler® device compared to a novel modification of the device to provide more effective dispersion and aerosolization of the coated albuterol powder.
The new mechanism of action for proof-of-concept testing consists of a bead (5.1 mm; expanded polystyrene foam) coated with drug powder, as opposed to the standard lactose formulation-filled capsule.
研究概览
研究类型
介入性
注册 (实际的)
6
阶段
- 不适用
联系人和位置
本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。
学习地点
-
-
North Carolina
-
Chapel Hill、North Carolina、美国、27599
- University of North Carolina at Chapel Hill, CEMALB
-
-
参与标准
研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。
资格标准
适合学习的年龄
18年 至 50年 (成人)
接受健康志愿者
是的
有资格学习的性别
全部
描述
Inclusion Criteria:
- healthy volunteers adults
Exclusion Criteria:
- chronic illness
学习计划
本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:单身的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:modified Handihaler DPI
|
subjects randomized to receive 1 inhaled dose on 2 separate days, each dose delivered 2-3 days apart.
The radiolabeled albuterol drug powder will be dispersed from either the DET bead-HandiHaler prototype or via the established HandiHaler device standard with the lactose-albuterol formulation provided to us by the sponsor.
|
|
安慰剂比较:standard Handihaler DPI
|
subjects randomized to receive 1 inhaled dose on 2 separate days, each dose delivered 2-3 days apart.
The radiolabeled albuterol drug powder will be dispersed from either the DET bead-HandiHaler prototype or via the established HandiHaler device standard with the lactose-albuterol formulation provided to us by the sponsor.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Fractional delivery of dry powder to the lung
大体时间:1-5 minutes post inhalation
|
To compare the in vivo performance,i.e. the fraction of drug loaded in device that is delivered to the lung, of the novel system in comparison with a standard marketed dry powder inhaler (DPI) using radio-imaging techniques.
The fraction delivered to the lung will be determined by gamma camera imaging of the lungs following inhalation of the radiolabeled powder from the standard vs. new device.
|
1-5 minutes post inhalation
|
合作者和调查者
在这里您可以找到参与这项研究的人员和组织。
研究记录日期
这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。
研究主要日期
学习开始
2011年12月1日
初级完成 (实际的)
2012年6月1日
研究完成 (实际的)
2012年6月1日
研究注册日期
首次提交
2011年12月12日
首先提交符合 QC 标准的
2011年12月15日
首次发布 (估计)
2011年12月20日
研究记录更新
最后更新发布 (估计)
2017年1月24日
上次提交的符合 QC 标准的更新
2017年1月20日
最后验证
2017年1月1日
更多信息
与本研究相关的术语
其他研究编号
- 11-1260
药物和器械信息、研究文件
研究美国 FDA 监管的药品
不
研究美国 FDA 监管的设备产品
不
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.