此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

External Immobilization Compared to Limited Immobilization Using a Novel Real-time Localization System of the Prostate

2016年5月13日 更新者:Dusten Macdonald, MD、U.S. Army Medical Research Acquisition Activity

This prospective study at MAMC evaluates the utility of a rigid pelvic external immobilization compared to limited immobilization using a novel real-time localization system of the prostate. The sample population will include patients referred to the radiation oncology services of both facilities for definitive treatment of prostate cancer. The study will enroll 20 subjects from MAMC and evaluate data on 860 radiation therapy fractions.

Subjects will have Beacon® Transponders implanted into the prostate to more precisely localize the position of the organ during radiation therapy. They will be randomized to rigid pelvic immobilization using a Vac-Lok® system or limited immobilization with a band around the patient's feet. They will then undergo radiation therapy planning with standard planning target margins. The Calypso® 4D Localization System will monitor, in real time, the position of the prostate target and adjust radiation treatments as required to ensure accurate treatment of the prostate gland. The time of, the number, and extent of adjustments will be recorded for analysis.

Hypothesis: 1. When treating only the prostate, treatment with rigid pelvic immobilization is not necessary when using real-time, state-of-the-art motion tracking of the prostate.

研究概览

地位

未知

条件

详细说明

Medical application: This study will seek to determine the utility of rigid external pelvic immobilization in patients who are set up using real-time, state-of-the-art motion tracking of the prostate. External immobilization devices have been criticized for being expensive, uncomfortable, time-consuming to make, occupying a lot of space in the treatment area, creating difficulties at the time of CT simulation, challenging for obese patients and obscuring skin marks that can help confirm patient set up. Omitting these devices (if found to be unnecessary) would potentially decrease treatment costs, improve patient comfort during treatment, and reduce overall treatment time. In high risk patients, gaining a better understanding of lymph node positioning relative to Calypso immobilization may allow for decreased PTV margins and therefore decreased normal tissue irradiated during radiation therapy.

Objective(s) of the investigation: This study will look at the efficacy of external pelvic immobilization in definitive radiation therapy of prostate cancer using a unique organ tracking system.

A. Primary Objective: To determine if rigid external pelvic immobilization demonstrates a reduction in positioning errors. This will be assessed by determining the median, mean and range of shifts performed in all 3 dimensions as part of initial isocenter set-up and during treatment using the Calypso system.

B. Secondary Objectives: The study will determine the simulation time, set up time, treatment time, total time and number of treatment interventions (repositioning/pausing) caused by organ/target motion beyond planning target volume (PTV) margin using real time localization. In the subset of high-risk patients, this study will assess positioning of the lymph node target using the combination of rigid external pelvic immobilization and the Calypso system.

研究类型

观察性的

注册 (预期的)

20

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Washington
      • Tacoma、Washington、美国、98431
        • Madigan Healthcare System

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

40年 及以上 (成人、年长者)

接受健康志愿者

是的

有资格学习的性别

男性

取样方法

非概率样本

研究人群

This study will include patients with prostate cancer for whom definitive radiation therapy is planned to the prostate. Patients will be referred from Urology and Radiation Oncology.

描述

Inclusion Criteria:

  • Histologically confirmed adenocarcinoma of the prostate
  • Stage T1 -T3a, N0 or NX, M0
  • Ability to comply with study schedule
  • Age 40 or older
  • Zubrod PS 0 or 1 (appendix 1)
  • Signed informed consent

Exclusion Criteria:

  • Node positive or metastatic prostate cancer
  • Prior treatment of prostate cancer with surgery, chemotherapy, cryotherapy or brachytherapy
  • History of prior pelvic radiotherapy
  • History of abdominoperineal resection
  • History of inflammatory bowel disease or connective tissue disease
  • History of HIV infection
  • History of chronic prostatitis or chronic cystitis
  • History of bleeding disorder or any active anticoagulation (excluding ASA) which cannot be safely discontinued for beacon placement
  • PT or INR outside normal range for institution
  • Active implanted devices such as cardiac pacemakers and automatic defibrillators.
  • Prosthetic implants in the pelvic region that contain metal or conductive materials (eg., an artificial hip).
  • Patients with maximum anterior-posterior separation through the torso minus the height of the center of the prostate greater than 17 cm (technical reason for Calypso System, see appendix 5).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Rigid external pelvic immobilization demonstrates a reduction in positioning errors.
大体时间:Measured at every treatment fraction for a total of approximately 8.5 weeks
This will be assessed by determining the median, mean and range of shifts performed in all 3 dimensions as part of initial isocenter set-up and during treatment using the Calypso system.
Measured at every treatment fraction for a total of approximately 8.5 weeks

次要结果测量

结果测量
措施说明
大体时间
Simulation time, set up time, treatment time, total time and number of treatment interventions (repositioning/pausing) caused by organ/target motion beyond planning target volume (PTV) margin using real time localization.
大体时间:Measured at simluation and every treatment fraction for a total of approximately 10 weeks
During each radiation treatment fraction, therapists will record these timepoints and number/duaration of treatment inverventions.
Measured at simluation and every treatment fraction for a total of approximately 10 weeks
Positioning of the lymph node target using the combination of rigid external pelvic immobilization and the Calypso system.
大体时间:Measured at every treatment fraction for a total of approximately 8.5 weeks
This will be analyzed in the subset of high-risk patients.
Measured at every treatment fraction for a total of approximately 8.5 weeks

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2009年12月1日

初级完成 (预期的)

2016年9月1日

研究完成 (预期的)

2017年8月1日

研究注册日期

首次提交

2012年4月26日

首先提交符合 QC 标准的

2012年4月27日

首次发布 (估计)

2012年5月1日

研究记录更新

最后更新发布 (估计)

2016年5月17日

上次提交的符合 QC 标准的更新

2016年5月13日

最后验证

2016年5月1日

更多信息

与本研究相关的术语

其他研究编号

  • W81XWH-08-2-0174, A-15214.1b
  • W81XWH-08-2-0174 (其他赠款/资助编号:US Army Medical Research Acquisition Activity)
  • 209099 (其他标识符:Madigan Army IRB)

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

3
订阅