- ICH GCP
- Registro de ensaios clínicos dos EUA
- Ensaio Clínico NCT01588938
External Immobilization Compared to Limited Immobilization Using a Novel Real-time Localization System of the Prostate
This prospective study at MAMC evaluates the utility of a rigid pelvic external immobilization compared to limited immobilization using a novel real-time localization system of the prostate. The sample population will include patients referred to the radiation oncology services of both facilities for definitive treatment of prostate cancer. The study will enroll 20 subjects from MAMC and evaluate data on 860 radiation therapy fractions.
Subjects will have Beacon® Transponders implanted into the prostate to more precisely localize the position of the organ during radiation therapy. They will be randomized to rigid pelvic immobilization using a Vac-Lok® system or limited immobilization with a band around the patient's feet. They will then undergo radiation therapy planning with standard planning target margins. The Calypso® 4D Localization System will monitor, in real time, the position of the prostate target and adjust radiation treatments as required to ensure accurate treatment of the prostate gland. The time of, the number, and extent of adjustments will be recorded for analysis.
Hypothesis: 1. When treating only the prostate, treatment with rigid pelvic immobilization is not necessary when using real-time, state-of-the-art motion tracking of the prostate.
Visão geral do estudo
Status
Condições
Descrição detalhada
Medical application: This study will seek to determine the utility of rigid external pelvic immobilization in patients who are set up using real-time, state-of-the-art motion tracking of the prostate. External immobilization devices have been criticized for being expensive, uncomfortable, time-consuming to make, occupying a lot of space in the treatment area, creating difficulties at the time of CT simulation, challenging for obese patients and obscuring skin marks that can help confirm patient set up. Omitting these devices (if found to be unnecessary) would potentially decrease treatment costs, improve patient comfort during treatment, and reduce overall treatment time. In high risk patients, gaining a better understanding of lymph node positioning relative to Calypso immobilization may allow for decreased PTV margins and therefore decreased normal tissue irradiated during radiation therapy.
Objective(s) of the investigation: This study will look at the efficacy of external pelvic immobilization in definitive radiation therapy of prostate cancer using a unique organ tracking system.
A. Primary Objective: To determine if rigid external pelvic immobilization demonstrates a reduction in positioning errors. This will be assessed by determining the median, mean and range of shifts performed in all 3 dimensions as part of initial isocenter set-up and during treatment using the Calypso system.
B. Secondary Objectives: The study will determine the simulation time, set up time, treatment time, total time and number of treatment interventions (repositioning/pausing) caused by organ/target motion beyond planning target volume (PTV) margin using real time localization. In the subset of high-risk patients, this study will assess positioning of the lymph node target using the combination of rigid external pelvic immobilization and the Calypso system.
Tipo de estudo
Inscrição (Antecipado)
Contactos e Locais
Locais de estudo
-
-
Washington
-
Tacoma, Washington, Estados Unidos, 98431
- Madigan Healthcare System
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
Descrição
Inclusion Criteria:
- Histologically confirmed adenocarcinoma of the prostate
- Stage T1 -T3a, N0 or NX, M0
- Ability to comply with study schedule
- Age 40 or older
- Zubrod PS 0 or 1 (appendix 1)
- Signed informed consent
Exclusion Criteria:
- Node positive or metastatic prostate cancer
- Prior treatment of prostate cancer with surgery, chemotherapy, cryotherapy or brachytherapy
- History of prior pelvic radiotherapy
- History of abdominoperineal resection
- History of inflammatory bowel disease or connective tissue disease
- History of HIV infection
- History of chronic prostatitis or chronic cystitis
- History of bleeding disorder or any active anticoagulation (excluding ASA) which cannot be safely discontinued for beacon placement
- PT or INR outside normal range for institution
- Active implanted devices such as cardiac pacemakers and automatic defibrillators.
- Prosthetic implants in the pelvic region that contain metal or conductive materials (eg., an artificial hip).
- Patients with maximum anterior-posterior separation through the torso minus the height of the center of the prostate greater than 17 cm (technical reason for Calypso System, see appendix 5).
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Rigid external pelvic immobilization demonstrates a reduction in positioning errors.
Prazo: Measured at every treatment fraction for a total of approximately 8.5 weeks
|
This will be assessed by determining the median, mean and range of shifts performed in all 3 dimensions as part of initial isocenter set-up and during treatment using the Calypso system.
|
Measured at every treatment fraction for a total of approximately 8.5 weeks
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
|---|---|---|
|
Simulation time, set up time, treatment time, total time and number of treatment interventions (repositioning/pausing) caused by organ/target motion beyond planning target volume (PTV) margin using real time localization.
Prazo: Measured at simluation and every treatment fraction for a total of approximately 10 weeks
|
During each radiation treatment fraction, therapists will record these timepoints and number/duaration of treatment inverventions.
|
Measured at simluation and every treatment fraction for a total of approximately 10 weeks
|
|
Positioning of the lymph node target using the combination of rigid external pelvic immobilization and the Calypso system.
Prazo: Measured at every treatment fraction for a total of approximately 8.5 weeks
|
This will be analyzed in the subset of high-risk patients.
|
Measured at every treatment fraction for a total of approximately 8.5 weeks
|
Colaboradores e Investigadores
Patrocinador
Colaboradores
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Estimativa)
Atualizações de registro de estudo
Última Atualização Postada (Estimativa)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- W81XWH-08-2-0174, A-15214.1b
- W81XWH-08-2-0174 (Número de outro subsídio/financiamento: US Army Medical Research Acquisition Activity)
- 209099 (Outro identificador: Madigan Army IRB)
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .