此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Use of Cardiac-MRI to Predict Results for People With Severe Aortic Stenosis

Utilization of Cardiac Magnetic Resonance Imaging to Predict Clinical Outcomes of Patients With Severe Aortic Stenosis

Background:

- Aortic valve stenosis is a disease that makes a major heart valve get smaller. This reduces heart function and causes death. Severe aortic stenosis (AS) can be treated in a couple of ways, including replacing a heart valve.

Objectives:

Researchers want to study fibrosis in the heart. A sub-study will test whether heart function and blood supply improve after a valve replacement.

Eligibility:

- Adults at least 18 years old with aortic stenosis.

Design:

  • Participants will visit a clinic for 1 day for magnetic resonance imaging (MRI) of their heart. This uses magnets, radio waves, and computers to produce detailed pictures of the heart.
  • After this visit, participants will have their aortic valve procedure at the the Washington Hospital Center. A hospital team will contact participants for 1 year by phone or email. This follow-up will consist of 15 minutes of questions about the participant s health status.
  • Some participants will join a sub-study.
  • They will be given an additional medication to evaluate the blood supply of the heart.
  • They will visit a clinic for 1 day for an MRI of their heart, as part of the main study, prior to the aortic valve replacement.
  • After they have their valve replaced at the hospital, they will return to the clinic for another MRI.
  • They will have the same follow-up as in the main study.

研究概览

地位

撤销

详细说明

Aortic valve stenosis is a disease that causes narrowing of a major heart valve, and that reduces heart function and causes death. The purpose of this protocol is to use magnetic resonance imaging of the heart to identify which patients would benefit from replacement of the diseased valve.

研究类型

观察性的

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

  • INCLUSION CRITERIA:

Subjects must meet all the following inclusion criteria prior to enrollment into the trial:

  1. Severe aortic stenosis defined as aortic valve area of less than 1 cm(2) or index area of 0.6 cm(2)/m(2) by echocardiography.
  2. Symptomatic patients with aortic stenosis referred for medically indicated AVR
  3. LV EF less than or equal to 0.50
  4. Signed informed consent to participate in the study.

    Specific criteria for MR perfusion sub-study:

  5. Absence of any significant coronary lesions or presence of coronary disease for conservative (medical) therapy<TAB>.

EXCLUSION CRITERIA:

  1. Inability to sign written informed consent.
  2. Subjects with contraindication to MRI scanning, including the following devices or conditions:

    • Cardiac pacemaker or implantable defibrillator
    • Cerebral aneurysm clip
    • Neural stimulator (e.g. TENS-Unit)
    • Any type of ear implant
    • Ocular foreign body (e.g. metal shavings)
    • Any implanted device (e.g. insulin pump, drug infusion device)
    • Metal shrapnel or bullet.
    • Atrial fibrillation
  3. Subjects with a known hypersensitivity, allergy or contraindication to iodine or gadolinium
  4. Impaired renal excretory function, calculated as Glomerular Filtration Rate (GFR) <30mL/min/1.73m(2).
  5. Contraindications for intravenous adenosine infusion:

    • Known hypersensitivity to adenosine
    • Known or suspected significant bronchoconstrictive or bronchospastic disease
    • 2nd or 3rd degree atrioventricular (AV) block unless with permanent pacemaker
    • Sinus bradycardia (heart rate < 45 bpm) unless with permanent pacemaker
    • Systemic arterial hypotension (< 90 mmHg)
  6. Presence of any coexisting severe valvular disorder.
  7. Pregnancy or breast feeding (women of childbearing potential will have a serum or urine pregnancy test).
  8. Need for emergency surgery for any reason.
  9. Any case in which the practicing physician asserts that enrollment in the protocol will adversely affect the patient treatment course.

Specific exclusion criteria for MR perfusion sub-study:

No detectable reversible ischemia on pre-treatment/procedure cardiac MRI.

Subject underwent transcatheter AVR as part of one of the transcatheter heart valve trials (i.e. PARTNER trial or the pivotal CoreValve trial).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 时间观点:预期

研究衡量的是什么?

主要结果指标

结果测量
大体时间
To assess the ability of cardiac MRI measurement of extracellular volume fraction (related to myocardial fibrosis) to predict short and long term LV function of subjects with severe aortic stenosis undergoing transcatheter AVR.
大体时间:3 years
3 years

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始

2013年6月27日

初级完成 (预期的)

2016年12月31日

研究完成 (预期的)

2016年12月31日

研究注册日期

首次提交

2013年7月18日

首先提交符合 QC 标准的

2013年7月18日

首次发布 (估计)

2013年7月23日

研究记录更新

最后更新发布 (实际的)

2019年9月13日

上次提交的符合 QC 标准的更新

2019年9月12日

最后验证

2014年4月8日

更多信息

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅