Questa pagina è stata tradotta automaticamente e l'accuratezza della traduzione non è garantita. Si prega di fare riferimento al Versione inglese per un testo di partenza.

Use of Cardiac-MRI to Predict Results for People With Severe Aortic Stenosis

12 settembre 2019 aggiornato da: National Heart, Lung, and Blood Institute (NHLBI)

Utilization of Cardiac Magnetic Resonance Imaging to Predict Clinical Outcomes of Patients With Severe Aortic Stenosis

Background:

- Aortic valve stenosis is a disease that makes a major heart valve get smaller. This reduces heart function and causes death. Severe aortic stenosis (AS) can be treated in a couple of ways, including replacing a heart valve.

Objectives:

Researchers want to study fibrosis in the heart. A sub-study will test whether heart function and blood supply improve after a valve replacement.

Eligibility:

- Adults at least 18 years old with aortic stenosis.

Design:

  • Participants will visit a clinic for 1 day for magnetic resonance imaging (MRI) of their heart. This uses magnets, radio waves, and computers to produce detailed pictures of the heart.
  • After this visit, participants will have their aortic valve procedure at the the Washington Hospital Center. A hospital team will contact participants for 1 year by phone or email. This follow-up will consist of 15 minutes of questions about the participant s health status.
  • Some participants will join a sub-study.
  • They will be given an additional medication to evaluate the blood supply of the heart.
  • They will visit a clinic for 1 day for an MRI of their heart, as part of the main study, prior to the aortic valve replacement.
  • After they have their valve replaced at the hospital, they will return to the clinic for another MRI.
  • They will have the same follow-up as in the main study.

Panoramica dello studio

Stato

Ritirato

Descrizione dettagliata

Aortic valve stenosis is a disease that causes narrowing of a major heart valve, and that reduces heart function and causes death. The purpose of this protocol is to use magnetic resonance imaging of the heart to identify which patients would benefit from replacement of the diseased valve.

Tipo di studio

Osservativo

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

18 anni e precedenti (Adulto, Adulto più anziano)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

  • INCLUSION CRITERIA:

Subjects must meet all the following inclusion criteria prior to enrollment into the trial:

  1. Severe aortic stenosis defined as aortic valve area of less than 1 cm(2) or index area of 0.6 cm(2)/m(2) by echocardiography.
  2. Symptomatic patients with aortic stenosis referred for medically indicated AVR
  3. LV EF less than or equal to 0.50
  4. Signed informed consent to participate in the study.

    Specific criteria for MR perfusion sub-study:

  5. Absence of any significant coronary lesions or presence of coronary disease for conservative (medical) therapy<TAB>.

EXCLUSION CRITERIA:

  1. Inability to sign written informed consent.
  2. Subjects with contraindication to MRI scanning, including the following devices or conditions:

    • Cardiac pacemaker or implantable defibrillator
    • Cerebral aneurysm clip
    • Neural stimulator (e.g. TENS-Unit)
    • Any type of ear implant
    • Ocular foreign body (e.g. metal shavings)
    • Any implanted device (e.g. insulin pump, drug infusion device)
    • Metal shrapnel or bullet.
    • Atrial fibrillation
  3. Subjects with a known hypersensitivity, allergy or contraindication to iodine or gadolinium
  4. Impaired renal excretory function, calculated as Glomerular Filtration Rate (GFR) <30mL/min/1.73m(2).
  5. Contraindications for intravenous adenosine infusion:

    • Known hypersensitivity to adenosine
    • Known or suspected significant bronchoconstrictive or bronchospastic disease
    • 2nd or 3rd degree atrioventricular (AV) block unless with permanent pacemaker
    • Sinus bradycardia (heart rate < 45 bpm) unless with permanent pacemaker
    • Systemic arterial hypotension (< 90 mmHg)
  6. Presence of any coexisting severe valvular disorder.
  7. Pregnancy or breast feeding (women of childbearing potential will have a serum or urine pregnancy test).
  8. Need for emergency surgery for any reason.
  9. Any case in which the practicing physician asserts that enrollment in the protocol will adversely affect the patient treatment course.

Specific exclusion criteria for MR perfusion sub-study:

No detectable reversible ischemia on pre-treatment/procedure cardiac MRI.

Subject underwent transcatheter AVR as part of one of the transcatheter heart valve trials (i.e. PARTNER trial or the pivotal CoreValve trial).

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Prospettive temporali: Prospettiva

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Lasso di tempo
To assess the ability of cardiac MRI measurement of extracellular volume fraction (related to myocardial fibrosis) to predict short and long term LV function of subjects with severe aortic stenosis undergoing transcatheter AVR.
Lasso di tempo: 3 years
3 years

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio

27 giugno 2013

Completamento primario (Anticipato)

31 dicembre 2016

Completamento dello studio (Anticipato)

31 dicembre 2016

Date di iscrizione allo studio

Primo inviato

18 luglio 2013

Primo inviato che soddisfa i criteri di controllo qualità

18 luglio 2013

Primo Inserito (Stima)

23 luglio 2013

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

13 settembre 2019

Ultimo aggiornamento inviato che soddisfa i criteri QC

12 settembre 2019

Ultimo verificato

8 aprile 2014

Maggiori informazioni

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Stenosi della valvola aortica

3
Sottoscrivi