此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Accelerometer Use in the Prevention of Exercise-Associated Hypoglycemia in Type 1 Diabetes: Outpatient Exercise Protocol

2019年12月17日 更新者:Bruce Buckingham、Stanford University

Manually suspending an insulin pump at the beginning of aerobic exercise reduces the risk of exercise-associated hypoglycemia (low blood sugar) in patients with type 1 diabetes (T1D). However, since patients with T1D often do not make exercise-related adjustments to their insulin regimen, our group has developed an algorithm to initiate pump suspension in a user-independent manner upon projecting exercise-associated hypoglycemia. The current study seeks to test the efficacy of this algorithm by asking users to participate in a sports camp while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which will communicate electronically to a pump shutoff algorithm. On one of the days the algorithm will be used, while on the other day their normal insulin rate will continue for comparative purposes.

The investigators hypothesize that the use of an accelerometer-augmented computer algorithm for insulin pump suspension during exercise will result in significantly fewer episodes of hypoglycemia (both during exercise and in post-exercise monitoring) than in exercise without a pump suspension algorithm.

研究概览

详细说明

Regular aerobic exercise confers a plethora of health benefits to all individuals and is considered an essential component of the management of type 1 diabetes (T1D) [1]. However, in contrast to non-diabetic subjects - in whom the increased muscle energy requirement during exercise leads to suppression of endogenous insulin secretion - patients with T1D are dependent upon exogenous insulin and are thus at risk for exercise-associated hypoglycemia [1]. Exercise-associated hypoglycemia is the most frequently reported adverse event related to exercise in diabetes [2] and hypoglycemia can occur during exercise or several hours afterwards [3,4]. Although previous research has shown that pre-meal dose reduction of subcutaneous insulin can be effective at decreasing the incidence of exercise-associated hypoglycemia [5], patients with T1D often do not perform such adjustments [6,7].

In contrast to subcutaneous insulin injections, which are reliant upon the patient or caretaker to determine dosage, the insulin pump provides a unique opportunity to avoid hypoglycemia via user-independent, computer-based algorithms for determining insulin delivery. Previous research conducted here at Stanford has demonstrated that algorithms based on continuous glucose monitor (CGM) data can prevent hypoglycemia in the sedentary setting by inducing insulin pump suspension [8-10]. In addition, a study of children and adolescents conducted at Stanford (as a center in the DirecNet group) demonstrated that suspending an insulin pump at the beginning of a period of moderate aerobic exercise reduces the risk of hypoglycemia during that exercise period and subsequently overnight [11]. Thus, by utilizing exercise-detecting accelerometers and an algorithm to initiate pump suspension during exercise, it is likely possible that people with diabetes could avoid exercise-associated hypoglycemia even if they failed to manually alter their pump settings. However, to date, no published studies have utilized accelerometer-derived data in an insulin pump suspension algorithm during exercise.

Accelerometers are light-weight motion-sensing devices that can be worn to provide information about the intensity and duration of physical activity [12]. They are small, inexpensive, and could easily be incorporated into current sensors and "patch" pumps. They can also be used independently or combined with a heart rate monitor (HRM) [13], although most commercially available HRMs currently require a chest strap that can be uncomfortable to wear. Previous studies evaluating the effect of physical activity on insulin sensitivity have utilized accelerometers (worn on a belt at the small of the back, the right side of the trunk in the mid-axillary line, or the left side of the chest) with and without HRMs for activity recognition during subjects' everyday lives. These data were used to classify activity as sedentary, light, moderate, or vigorous based on acceleration signal counts measured over one-minute intervals [13-17]. One study investigated four different accelerometers in a clinical research setting and found each to be very accurate in assessing the intensity of physical activity, regardless of subjects' body habitus [18]. Thus, these devices can provide a reliable means by which the onset, duration, and intensity of exercise can be recognized and reported in real-time to the other components of an artificial pancreas. When combined with CGM and insulin delivery data, this exercise information is a valuable tool in designing an algorithm to decrease or stop insulin delivery in order to decrease the risk of exercise-associated hypoglycemia.

In the first phase of this study (in press), 22 subjects with type 1 diabetes went about their everyday lives while wearing an insulin pump, CGM, and accelerometer/heart rate monitor. After the monitoring period, the devices were downloaded and the data were used to augment an existing predictive low glucose suspend (PLGS) algorithm to incorporate activity. In a computer simulator, the PLGS algorithm reduced hypoglycemia by 64%, compared to 73% and 76% reductions for the accelerometer-augmented and HRM-augmented algorithms, respectively.

In the next phase of this study, we seek to test the newly developed algorithm in a real-life setting in the form of a structured sports (soccer) camp to further see if modifications to the algorithm are required.

研究类型

介入性

注册 (实际的)

18

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • California
      • Stanford、California、美国、94305
        • Stanford University

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

8年 至 25年 (孩子、成人)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Clinical diagnosis of type 1 diabetes for 1-20 years. The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.
  • Age 8 to 25 years old.
  • On daily use of an insulin pump and not anticipating a change prior to the subject's completion of the study.
  • Willingness to allow for CGM insertion (if not already using a study-designated CGM) for use during the study.
  • HbA1c <10%.
  • Parent/guardian and subject understand the study protocol and agree to comply with it.
  • Informed Consent Form signed by the parent/guardian and Child Assent Form signed.

Exclusion Criteria:

  • A history of recent injury to body or limb, Addison's disease, muscular disorder, organ/bone marrow transplant, heart disease, or use of any medication or other significant medical disorder if that injury, medication or disease in the judgment of the investigator will affect the completion of the exercise protocol.
  • Current use of glucocorticoid medication (by any route of administration).
  • Current use of a beta blocker medication.
  • Severe hypoglycemia resulting in seizure or loss of consciousness in the four weeks prior to sports camp (if a severe episode occurs after the first but prior to the scheduled second admission, the visit will be deferred).
  • Active infection (if at the time of the planned second visit an infection is present, the visit will be deferred).

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:On-algorithm first, then Off-algorithm
Users will participate in two sports camp sessions while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which can communicate electronically to a pump shutoff algorithm that insulin delivery should be shut off. On one sports day, the algorithm is turned on; on the other day, the algorithm is turned off.
If the computer algorithm senses impending risk for hypoglycemia it sends an alert to an on-site physician to recommend a manual suspension of the subject's insulin pump
其他名称:
  • Augmented predictive low glucose suspend algorithm
实验性的:Off-algorithm first, then On-algorithm
Users will participate in two sports camp sessions while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which can communicate electronically to a pump shutoff algorithm that insulin delivery should be shut off. On one sports day, the algorithm is turned on; on the other day, the algorithm is turned off.
If the computer algorithm senses impending risk for hypoglycemia it sends an alert to an on-site physician to recommend a manual suspension of the subject's insulin pump
其他名称:
  • Augmented predictive low glucose suspend algorithm

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Count of Participants Experiencing a Hypoglycemic Event During Scheduled Exercise
大体时间:Measurements occurring during exercise (up to 8 hours)
The primary outcome will be a hypoglycemic event defined as (1) any meter blood glucose (BG) reading of ≤60 mg/dl, (2) two consecutive meter BG readings ≤70 mg/dl done within one hour, or (3) any instance in which carbohydrates were given at a subject's request for symptoms of hypoglycemia
Measurements occurring during exercise (up to 8 hours)

次要结果测量

结果测量
措施说明
大体时间
Count of Participants With Hypoglycemia in the Post Exercise Period
大体时间:In the time following exercise until the following morning (up to 24 hours)
A hypoglycemic event was defined as (1) any meter blood glucose (BG) reading of ≤60 mg/dl, (2) two consecutive meter BG readings ≤70 mg/dl done within one hour, or (3) any instance in which carbohydrates were given at a subject's request for symptoms of hypoglycemia
In the time following exercise until the following morning (up to 24 hours)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Bruce A Buckingham, MD、Stanford University

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2014年3月12日

初级完成 (实际的)

2014年5月1日

研究完成 (实际的)

2014年5月1日

研究注册日期

首次提交

2014年1月17日

首先提交符合 QC 标准的

2014年1月24日

首次发布 (估计)

2014年1月28日

研究记录更新

最后更新发布 (实际的)

2019年12月27日

上次提交的符合 QC 标准的更新

2019年12月17日

最后验证

2019年12月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

是的

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅