Accelerometer Use in the Prevention of Exercise-Associated Hypoglycemia in Type 1 Diabetes: Outpatient Exercise Protocol

17 dicembre 2019 aggiornato da: Bruce Buckingham, Stanford University

Manually suspending an insulin pump at the beginning of aerobic exercise reduces the risk of exercise-associated hypoglycemia (low blood sugar) in patients with type 1 diabetes (T1D). However, since patients with T1D often do not make exercise-related adjustments to their insulin regimen, our group has developed an algorithm to initiate pump suspension in a user-independent manner upon projecting exercise-associated hypoglycemia. The current study seeks to test the efficacy of this algorithm by asking users to participate in a sports camp while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which will communicate electronically to a pump shutoff algorithm. On one of the days the algorithm will be used, while on the other day their normal insulin rate will continue for comparative purposes.

The investigators hypothesize that the use of an accelerometer-augmented computer algorithm for insulin pump suspension during exercise will result in significantly fewer episodes of hypoglycemia (both during exercise and in post-exercise monitoring) than in exercise without a pump suspension algorithm.

Panoramica dello studio

Stato

Completato

Condizioni

Descrizione dettagliata

Regular aerobic exercise confers a plethora of health benefits to all individuals and is considered an essential component of the management of type 1 diabetes (T1D) [1]. However, in contrast to non-diabetic subjects - in whom the increased muscle energy requirement during exercise leads to suppression of endogenous insulin secretion - patients with T1D are dependent upon exogenous insulin and are thus at risk for exercise-associated hypoglycemia [1]. Exercise-associated hypoglycemia is the most frequently reported adverse event related to exercise in diabetes [2] and hypoglycemia can occur during exercise or several hours afterwards [3,4]. Although previous research has shown that pre-meal dose reduction of subcutaneous insulin can be effective at decreasing the incidence of exercise-associated hypoglycemia [5], patients with T1D often do not perform such adjustments [6,7].

In contrast to subcutaneous insulin injections, which are reliant upon the patient or caretaker to determine dosage, the insulin pump provides a unique opportunity to avoid hypoglycemia via user-independent, computer-based algorithms for determining insulin delivery. Previous research conducted here at Stanford has demonstrated that algorithms based on continuous glucose monitor (CGM) data can prevent hypoglycemia in the sedentary setting by inducing insulin pump suspension [8-10]. In addition, a study of children and adolescents conducted at Stanford (as a center in the DirecNet group) demonstrated that suspending an insulin pump at the beginning of a period of moderate aerobic exercise reduces the risk of hypoglycemia during that exercise period and subsequently overnight [11]. Thus, by utilizing exercise-detecting accelerometers and an algorithm to initiate pump suspension during exercise, it is likely possible that people with diabetes could avoid exercise-associated hypoglycemia even if they failed to manually alter their pump settings. However, to date, no published studies have utilized accelerometer-derived data in an insulin pump suspension algorithm during exercise.

Accelerometers are light-weight motion-sensing devices that can be worn to provide information about the intensity and duration of physical activity [12]. They are small, inexpensive, and could easily be incorporated into current sensors and "patch" pumps. They can also be used independently or combined with a heart rate monitor (HRM) [13], although most commercially available HRMs currently require a chest strap that can be uncomfortable to wear. Previous studies evaluating the effect of physical activity on insulin sensitivity have utilized accelerometers (worn on a belt at the small of the back, the right side of the trunk in the mid-axillary line, or the left side of the chest) with and without HRMs for activity recognition during subjects' everyday lives. These data were used to classify activity as sedentary, light, moderate, or vigorous based on acceleration signal counts measured over one-minute intervals [13-17]. One study investigated four different accelerometers in a clinical research setting and found each to be very accurate in assessing the intensity of physical activity, regardless of subjects' body habitus [18]. Thus, these devices can provide a reliable means by which the onset, duration, and intensity of exercise can be recognized and reported in real-time to the other components of an artificial pancreas. When combined with CGM and insulin delivery data, this exercise information is a valuable tool in designing an algorithm to decrease or stop insulin delivery in order to decrease the risk of exercise-associated hypoglycemia.

In the first phase of this study (in press), 22 subjects with type 1 diabetes went about their everyday lives while wearing an insulin pump, CGM, and accelerometer/heart rate monitor. After the monitoring period, the devices were downloaded and the data were used to augment an existing predictive low glucose suspend (PLGS) algorithm to incorporate activity. In a computer simulator, the PLGS algorithm reduced hypoglycemia by 64%, compared to 73% and 76% reductions for the accelerometer-augmented and HRM-augmented algorithms, respectively.

In the next phase of this study, we seek to test the newly developed algorithm in a real-life setting in the form of a structured sports (soccer) camp to further see if modifications to the algorithm are required.

Tipo di studio

Interventistico

Iscrizione (Effettivo)

18

Fase

  • Non applicabile

Contatti e Sedi

Questa sezione fornisce i recapiti di coloro che conducono lo studio e informazioni su dove viene condotto lo studio.

Luoghi di studio

    • California
      • Stanford, California, Stati Uniti, 94305
        • Stanford University

Criteri di partecipazione

I ricercatori cercano persone che corrispondano a una certa descrizione, chiamata criteri di ammissibilità. Alcuni esempi di questi criteri sono le condizioni generali di salute di una persona o trattamenti precedenti.

Criteri di ammissibilità

Età idonea allo studio

Da 8 anni a 25 anni (Bambino, Adulto)

Accetta volontari sani

No

Sessi ammissibili allo studio

Tutto

Descrizione

Inclusion Criteria:

  • Clinical diagnosis of type 1 diabetes for 1-20 years. The diagnosis of type 1 diabetes is based on the investigator's judgment; C peptide level and antibody determinations are not needed.
  • Age 8 to 25 years old.
  • On daily use of an insulin pump and not anticipating a change prior to the subject's completion of the study.
  • Willingness to allow for CGM insertion (if not already using a study-designated CGM) for use during the study.
  • HbA1c <10%.
  • Parent/guardian and subject understand the study protocol and agree to comply with it.
  • Informed Consent Form signed by the parent/guardian and Child Assent Form signed.

Exclusion Criteria:

  • A history of recent injury to body or limb, Addison's disease, muscular disorder, organ/bone marrow transplant, heart disease, or use of any medication or other significant medical disorder if that injury, medication or disease in the judgment of the investigator will affect the completion of the exercise protocol.
  • Current use of glucocorticoid medication (by any route of administration).
  • Current use of a beta blocker medication.
  • Severe hypoglycemia resulting in seizure or loss of consciousness in the four weeks prior to sports camp (if a severe episode occurs after the first but prior to the scheduled second admission, the visit will be deferred).
  • Active infection (if at the time of the planned second visit an infection is present, the visit will be deferred).

Piano di studio

Questa sezione fornisce i dettagli del piano di studio, compreso il modo in cui lo studio è progettato e ciò che lo studio sta misurando.

Come è strutturato lo studio?

Dettagli di progettazione

  • Scopo principale: Trattamento
  • Assegnazione: Randomizzato
  • Modello interventistico: Assegnazione incrociata
  • Mascheramento: Nessuno (etichetta aperta)

Armi e interventi

Gruppo di partecipanti / Arm
Intervento / Trattamento
Sperimentale: On-algorithm first, then Off-algorithm
Users will participate in two sports camp sessions while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which can communicate electronically to a pump shutoff algorithm that insulin delivery should be shut off. On one sports day, the algorithm is turned on; on the other day, the algorithm is turned off.
If the computer algorithm senses impending risk for hypoglycemia it sends an alert to an on-site physician to recommend a manual suspension of the subject's insulin pump
Altri nomi:
  • Augmented predictive low glucose suspend algorithm
Sperimentale: Off-algorithm first, then On-algorithm
Users will participate in two sports camp sessions while wearing an insulin pump, continuous glucose monitor, and accelerometer/heart rate monitor (to detect exercise), which can communicate electronically to a pump shutoff algorithm that insulin delivery should be shut off. On one sports day, the algorithm is turned on; on the other day, the algorithm is turned off.
If the computer algorithm senses impending risk for hypoglycemia it sends an alert to an on-site physician to recommend a manual suspension of the subject's insulin pump
Altri nomi:
  • Augmented predictive low glucose suspend algorithm

Cosa sta misurando lo studio?

Misure di risultato primarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Count of Participants Experiencing a Hypoglycemic Event During Scheduled Exercise
Lasso di tempo: Measurements occurring during exercise (up to 8 hours)
The primary outcome will be a hypoglycemic event defined as (1) any meter blood glucose (BG) reading of ≤60 mg/dl, (2) two consecutive meter BG readings ≤70 mg/dl done within one hour, or (3) any instance in which carbohydrates were given at a subject's request for symptoms of hypoglycemia
Measurements occurring during exercise (up to 8 hours)

Misure di risultato secondarie

Misura del risultato
Misura Descrizione
Lasso di tempo
Count of Participants With Hypoglycemia in the Post Exercise Period
Lasso di tempo: In the time following exercise until the following morning (up to 24 hours)
A hypoglycemic event was defined as (1) any meter blood glucose (BG) reading of ≤60 mg/dl, (2) two consecutive meter BG readings ≤70 mg/dl done within one hour, or (3) any instance in which carbohydrates were given at a subject's request for symptoms of hypoglycemia
In the time following exercise until the following morning (up to 24 hours)

Collaboratori e investigatori

Qui è dove troverai le persone e le organizzazioni coinvolte in questo studio.

Investigatori

  • Investigatore principale: Bruce A Buckingham, MD, Stanford University

Pubblicazioni e link utili

La persona responsabile dell'inserimento delle informazioni sullo studio fornisce volontariamente queste pubblicazioni. Questi possono riguardare qualsiasi cosa relativa allo studio.

Pubblicazioni generali

Studiare le date dei record

Queste date tengono traccia dell'avanzamento della registrazione dello studio e dell'invio dei risultati di sintesi a ClinicalTrials.gov. I record degli studi e i risultati riportati vengono esaminati dalla National Library of Medicine (NLM) per assicurarsi che soddisfino specifici standard di controllo della qualità prima di essere pubblicati sul sito Web pubblico.

Studia le date principali

Inizio studio (Effettivo)

12 marzo 2014

Completamento primario (Effettivo)

1 maggio 2014

Completamento dello studio (Effettivo)

1 maggio 2014

Date di iscrizione allo studio

Primo inviato

17 gennaio 2014

Primo inviato che soddisfa i criteri di controllo qualità

24 gennaio 2014

Primo Inserito (Stima)

28 gennaio 2014

Aggiornamenti dei record di studio

Ultimo aggiornamento pubblicato (Effettivo)

27 dicembre 2019

Ultimo aggiornamento inviato che soddisfa i criteri QC

17 dicembre 2019

Ultimo verificato

1 dicembre 2019

Maggiori informazioni

Termini relativi a questo studio

Informazioni su farmaci e dispositivi, documenti di studio

Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti

No

Studia un dispositivo regolamentato dalla FDA degli Stati Uniti

Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .

Prove cliniche su Diabete di tipo 1

Sottoscrivi