此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Low-Level EMF Stimulation for Paroxysmal Atrial Fibrillation

2019年12月18日 更新者:University of Oklahoma

Effect of Low-Level Electromagnetic Field Stimulation on Patients With Paroxysmal Atrial Fibrillation

This research has two main specific aims. First, a commercially-available stimulator will be utilized to assess the effect of low-level electromagnetic field (EMF) stimulation on atrial fibrillation (AF) inducibility in patients with paroxysmal AF presenting for catheter ablation as compared to sham stimulation. We hypothesize a reduction in AF inducibility in patients treated with EMF stimulation. Second, we aim to assess for the effect of low-level EMF on level of systemic inflammatory mediators. We hypothesize a reduction in the level of the inflammatory mediator tissue necrosis factor (TNF)-α in patients treated with EMF stimulation as compared to sham stimulation. The long-term objective of this research is to develop low-level EMF as a therapeutic alternative for patients with AF, and this research will help to determine the efficacy of low-level pulsed EMF in this regard.

研究概览

详细说明

This is a prospective, randomized, sham-controlled trial. Patients will be enrolled upon presentation to our electrophysiology (EP) lab for ablation of paroxysmal AF. After informed consent is obtained, the patient will be randomized to one of two protocols that have been pre-programmed into the magnetic field stimulator. As described below, one of the protocols will be an active stimulation protocol, and one will be sham (i.e. no stimulation delivered). These will be named "Stim 1" and "Stim 2" in the computer. Because the specifics of the protocol are programmed into the stimulator by the device manufacturer, investigators will not know which of these two protocols is active vs. sham. The patient will then be brought to the EP lab for the procedure and will be placed on the lab table with their head positioned in the magnetic coil. Vascular access will then be obtained and diagnostic catheters placed as is standard practice for AF ablation.

Because the study is limited to patients with paroxysmal AF, patients will begin the study in normal sinus rhythm (NSR). Before the experimental protocol is begun, baseline electrophysiologic intervals will be recorded as is standard practice for all patients presenting for EP study. This will include measurement of the atrio-ventricular nodal effective refractory period (AVNERP) using programmed stimulation from the right atrial (RA) appendage, atrio-his (AH) interval, and his-ventricular (HV) interval per standard practice. Burst atrial pacing will then be utilized to induce AF. Measurements of the number of burst pacing attempts required to induce AF, as well as the AF cycle length, and duration of pacing-induced AF will be recorded. Attempts at AF induction will occur for 15 minutes. Prior to induction of AF, 5ml of venous blood will be drawn from the central venous sheaths to measure baseline levels of the inflammatory mediator (TNF)-α. These samples will be stored for analysis.

After baseline measurements are obtained, the coil will be turned on and whichever protocol the patient has been assigned to will be run. The system to be used contains a signal-generator coupled to a Helmholtz coil capable of producing a magnetic field in response to an electric current. The Helmholtz coil itself is has 9 inches of separation in between the two coils that allows for placement of the coil around the participant's head and upper neck. The choice of the head and neck as the site of stimulation is intended to target the vagus nerve as it exits the jugular foramen to course caudally in the carotid sheath. The system is designed to create a homogenous, isotropic magnetic field with a field strength from 1 to 99 pico-Tesla (pT) with a frequency range of 0.01 Hz to 50 Hz.

Active Stimulation will involve application of a pulsed-EMF with the parameters 0.032 micro-gauss (µG) at 0.89 Hz for 60 minutes. In participants randomized to sham stimulation, the coil will be positioned around the neck as previously described, but no current will be applied to the stimulator.

During the 60 minute stimulation time, trans-septal puncture and mapping of the left atrium will be performed as is standard practice for this procedure, but no ablation will be performed. After the 60 minute protocol is complete, venous blood samples will again be drawn (within 5 minutes of protocol completion), stored, and analyzed as previously described. If the patient remains in AF after the end of the 60 minute session, they will be electrically cardioverted to sinus rhythm. The same stimulation protocol as described previously will again be employed, again noting number of attempts required to induce AF, duration of pacing-induced AF, AF cycle length, and measurements of AVNERP, AH, HV intervals and levels of TNF-α.

研究类型

介入性

注册 (实际的)

18

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Oklahoma
      • Oklahoma City、Oklahoma、美国、73120
        • OU Health Sciences Center

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

21年 至 85年 (成人、年长者)

接受健康志愿者

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Adult patients aged 21-85 presenting for ablation of paroxysmal atrial fibrillation (episodes of atrial fibrillation lasting < 7 days with or without prior cardioversion)

Exclusion Criteria:

  • Left ventricular ejection fraction (LVEF) < 40%
  • Stroke or myocardial infarction within the past 6 months
  • Greater than moderate valvular stenosis or regurgitation as assessed by pre-procedure transthoracic echocardiogram (TTE)
  • Presence of a prosthetic heart valve.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:四人间

武器和干预

参与者组/臂
干预/治疗
实验性的:Active Stimulation
Participants will receive active EMF stimulation through the study device for 60 minutes during the procedure.
Low-level pulsed electromagnetic field stimulator delivered through a Helmholtz coil positioned around the participant's head and neck. Stimulation parameters are 0.032 µG at 0.89 Hz for 60 minutes.
假比较器:Sham Stimulation
The participant will be positioned in the stimulator, but no EMF stimulation will be delivered.
The stimulator will be placed around the participant's head and neck, but no EMF will be delivered.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in duration of pacing-induced atrial fibrillation
大体时间:60 minutes
Change in the duration of atrial fibrillation that is induced by burst-pacing compared between the two groups before and after the stimulation period.
60 minutes

次要结果测量

结果测量
措施说明
大体时间
Number of pacing attempts required to induce AF
大体时间:60 minutes
Number of burst-pacing attempts that are required to successfully induced atrial fibrillation, compared between the two groups before and after the stimulation period.
60 minutes
AF Cycle length
大体时间:60 minutes
Cycle length of induced atrial fibrillation, compared between the two groups before and after the stimulation period.
60 minutes
TNF-alpha levels
大体时间:60 minutes
Levels of the inflammatory mediator TNF-alpha measured in central venous blood, compared between the two groups before and after the stimulation period.
60 minutes

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Sunny Po, MD, PhD、University of Oklahoma

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2018年9月27日

初级完成 (实际的)

2019年11月26日

研究完成 (实际的)

2019年11月26日

研究注册日期

首次提交

2018年6月24日

首先提交符合 QC 标准的

2018年7月9日

首次发布 (实际的)

2018年7月20日

研究记录更新

最后更新发布 (实际的)

2019年12月20日

上次提交的符合 QC 标准的更新

2019年12月18日

最后验证

2019年12月1日

更多信息

与本研究相关的术语

其他研究编号

  • EMF for Atrial Fibrillation

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

药物和器械信息、研究文件

研究美国 FDA 监管的药品

研究美国 FDA 监管的设备产品

在美国制造并从美国出口的产品

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅