此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Novel MRI Assessment of Prostate Cancer VALIDATE-PRO (VALIDATE-PRO)

2022年7月28日 更新者:University College, London

Assessment of Diagnostic and Prognostic VALue, Identification of bIological Correlates, and Determination of TEchnical Performance of Novel Metabolic and Microstructural MRI in PROstate Cancer

For 50 years the diagnosis of prostate cancer has been with Prostate Specific Antigen (PSA) blood testing and prostate biopsy. However, this approach resulted in over-diagnosis, over-treatment and missed clinical important cancers. Multi-parametric MRI (mp-MRI) has provided a solution to some of these issues and the National Institute for health and Care Excellence has advocated the use of mp-MRI before biopsy in men with a suspicion for prostate cancer.

However, important challenges remain and the current way we pick up and assess prostate cancer can be improved. mp-MRI can miss significant cancer in around 11% of cases, 30% of positive MRI scans turn out not to have significant cancer at biopsy. Lastly, 34% of mp-MRI lesions are scored as in-determinant which sometimes makes decisions for further investigation and treatment unclear.

There are also difficulties predicting patients who will have progression of their disease or those who will not suffer harm from their cancer. Therefore the development of non-invasive tests and markers that can tell apart aggressive and non-aggressive disease would be extremely useful in deciding what treatment approach suits individual patients.

This study will investigate the use of three different novel MRI methods; Vascular, extracellular and restricted diffusion for cytometry in tumours (VERDICT), Luminal Imaging (LI) and hyperpolarised [1-13C]-pyruvate MRI (HYP-MRI). These scans help us to look at the microstructure as well as the metabolism of prostate tissue and may offer ways to better differentiate aggressive vs non-aggressive disease.

These scans will be performed in men with prostate cancer suitable for active surveillance at baseline and 1 year later to assess for prognostic indicators for progression in early prostate cancer.HYP-MRI will also be performed in men undergoing radical prostatectomy for validation of image findings and pathology. Whilst some men will have repeat scanning to asses for the repeatability of these techniques.

研究概览

地位

招聘中

条件

详细说明

PURPOSE AND DESIGN

The purpose of this study is to assess the ability of novel MRI techniques and their derived metrics in the diagnosis and prognostication of prostate cancer. Improving the diagnostic accuracy and investigating biomarkers with non- invasive MRI techniques have the promise of reducing unnecessary biopsies or radical treatment, as well as detecting those likely to progress at an earlier stage.

Vascular, Extracellular and Restricted Cytometry in Tumours (VERDICT) MRI

Diffusion-weighted imaging (DWI) is one of the most important sequences in mp-MRI of the prostate which reflects the diffusivity of water in cells and differs in cancerous tumour due to changes in cellular density, size, shape and arrangement. VERDICT is a novel framework which uses a more complex 3-compartment tissue model for diffusion of water; 1. Water trapped in cells, 2. Water in the vascular network and 3. Interstitial water. This allows us to make estimates of specific tissue properties such as the size and packing density of the cells, the vascular extracellular- extravascular space (EES) volume fractions. This methods is more biologically specific compared to conventional DWI. Studies in tumour xenograft models of colorectal cancer showed its ability to detect such known differences in the microstructure. At UCL we have applied VERDICT to the prostates of 78 men and were able to successfully differentiate between benign or clinically insignificant cancer and clinically significant tumours. This technique can be applied on commercially available MRI scanners and requires no additional contrast agents or requirements for the patient compared to conventional mp-MRI of the prostate.

Luminal Index (LI) MRI

Using a multi-echo T2 sequence we can differentiate between the relatively long T2 values of the luminal space and the short T2 values of the stromal and epithelial cells to estimate the fractional volume of water in each MR voxel, the luminal water fraction (LWF). Studies have shown a good correlation between LWF and histologically measure luminal fractional volume and hence promise to detect prostate cancer and predict Gleason score. Our refined local LI MRI sequence has been very good at differentiating clinically significant and non-significant tumours. This technique also requires no additional contrast agents or patient requirements to be completed.

Hyperpolarised [1-13C]-pyruvate MRI (HYP-MRI)

Cancer cell rely on enhanced glycolysis for their energy supply, a phenomenon known as the Warburg effect. This is a key discriminator of malignancy and normal tissues and has been successfully targeted with well-established imaging techniques such as Fluorodeoxyglucose (FDG) - Positron Emission Tomography (PET). HYP-MRI is able to image a part of this metabolic process in real-time. An injectable solution containing 13C labelled pyruvate which is hyperpolarised onsite in order to increase the eventual detectable signal. The naturally occurring metabolise pyruvate is converted to lactate with the attached 13C tag persisting enabling us to track the presence and conversion of pyruvate to lactate after the injection. It heralds the potential to differentiate tumours which are more likely to grow and metastasise from those which won't. This sequence requires an additional injection compared to standard mp-MRI and also uses an endorectal coil which is place inside the rectum for the duration of the scan.

The main objectives of this study are as follow and are addressed in three sub-studies:

  • To biologically validate HYP-MRI with correlation against biological measurements in men undergoing radical prostatectomy (BioVal: 44 patients)
  • Clinical validation of novel MRI techniques (VERDICT/LI/HYP-MRI) derived measurements for differentiating patients with aggressive (progressive) and indolent (non-progressive) prostate cancer in men entering active surveillance (ProVal: 120 patients)
  • Technical validation of novel MRI techniques (VERDICT/LI/HYP-MRI) through assessment of repeatability metrics from derived parameters (TecVal: 20 patients)

研究类型

观察性的

注册 (预期的)

234

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

学习地点

      • London、英国
        • 招聘中
        • University College London
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

男性

取样方法

非概率样本

研究人群

BioVal Cohort: Men scheduled for Prostatectomy

ProVal Cohort: Men initiating active surveillance and treatment for low grade disease.

描述

Inclusion Criteria:

  • Men aged >18 years
  • Pre-biopsy mp-MRI study performed within preceding 4 months
  • Likert/PIRADS score 4-5/5 lesion and/or biopsy confirmed Prostate cancer
  • Willing and able to provide written informed consent

Exclusion Criteria:

  • Men who suffer with claustrophobia or are unable to have an MRI e.g. implantable defibrillator, brain aneurysm clips or other implant, severe obesity or unable to lay still for length of scan.
  • Men with an impaired renal function (eGFR <30)
  • Previous prostate radiotherapy/focal treatment
  • Hormonal treatment for prostate cancer within preceding 3 months from consenting to the study.
  • Dementia or other neurological condition meaning participant lacks the capacity to consent.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
BioVal
BioVal is a single site validation study to determine the histological correlates underpinning signals derived from 13C-pyruvate HYP-MRI in men with known prostate cancer scheduled for prostatectomy.
ProVal
ProVal is a single site, prospective, longitudinal observational cohort study to determine the prognostic value of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known early prostate cancer on active surveillance.
TecVal
TecVal is a multi-site validation study to determine the inter-site repeatability and intra-site reproducibility of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known prostate cancer.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
ProVal Primary Objective
大体时间:3 years

To determine the prognostic value of VERDICT metrics for risk classification of patients with early prostate cancer suitable for active surveillance.

Quantitive value: fIC (intracellular (IC) volume fraction) among others within model.

3 years
ProVal Primary Objective
大体时间:3 years

To determine the prognostic value of Luminal Index for risk classification of patients with early prostate cancer suitable for active surveillance.

Quantitive value: Luminal index

3 years
ProVal Primary Objective
大体时间:3 years

To determine the prognostic value of 13C-HYP-MRI for risk classification of patients with early prostate cancer suitable for active surveillance.

Quantitive value: Lactate and pyruvate ratio parameters.

3 years
BioVal Primary Objective
大体时间:3 years

To estimate the association of 13C-HYP-MRI derived quantitative metrics against histological features of prostate cancer.

Quantitive value: Lactate and pyruvate ratio parameters.

3 years
BioVal Primary Objective
大体时间:3 years

To estimate the association of 13C-HYP-MRI derived quantitative metrics against histological features of prostate cancer.

Quantitive value: Gleason Grade

3 years
TecVal Primary Objective
大体时间:3 years

Inter-site repeatability and intra-site reproducibility of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known prostate cancer.

Metric: Repeatability and reproducibility co-efficients

3 years

次要结果测量

结果测量
措施说明
大体时间
ProVal Secondary Objective
大体时间:3 year

To examine the effects of histological progression of prostate cancer on VERDICT and LI-MRI quantitative metrics To determine whether baseline imaging metrics can predict time to radiological progression.

Metric: Gleason grade (used in combination with previous metrics discussed)

3 year

其他结果措施

结果测量
措施说明
大体时间
ProVal Tertiary Objective
大体时间:3 years

To link quantitative mpMRI, VERDICT MRI, LI-MRI and 13C-HYP-MRI quantitative features with molecular, genetic, epigenetic, transcriptomic and proteomic immune measurements made within patients recruited to the linked RECONCILE study.

Metric: genetic, molecular and epigenetic measurements.

3 years

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Shonit Punwani, MD PhD、UCL

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2021年1月29日

初级完成 (预期的)

2023年12月1日

研究完成 (预期的)

2024年6月1日

研究注册日期

首次提交

2021年5月17日

首先提交符合 QC 标准的

2021年8月18日

首次发布 (实际的)

2021年8月23日

研究记录更新

最后更新发布 (实际的)

2022年7月29日

上次提交的符合 QC 标准的更新

2022年7月28日

最后验证

2022年7月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅