Novel MRI Assessment of Prostate Cancer VALIDATE-PRO (VALIDATE-PRO)
Assessment of Diagnostic and Prognostic VALue, Identification of bIological Correlates, and Determination of TEchnical Performance of Novel Metabolic and Microstructural MRI in PROstate Cancer
For 50 years the diagnosis of prostate cancer has been with Prostate Specific Antigen (PSA) blood testing and prostate biopsy. However, this approach resulted in over-diagnosis, over-treatment and missed clinical important cancers. Multi-parametric MRI (mp-MRI) has provided a solution to some of these issues and the National Institute for health and Care Excellence has advocated the use of mp-MRI before biopsy in men with a suspicion for prostate cancer.
However, important challenges remain and the current way we pick up and assess prostate cancer can be improved. mp-MRI can miss significant cancer in around 11% of cases, 30% of positive MRI scans turn out not to have significant cancer at biopsy. Lastly, 34% of mp-MRI lesions are scored as in-determinant which sometimes makes decisions for further investigation and treatment unclear.
There are also difficulties predicting patients who will have progression of their disease or those who will not suffer harm from their cancer. Therefore the development of non-invasive tests and markers that can tell apart aggressive and non-aggressive disease would be extremely useful in deciding what treatment approach suits individual patients.
This study will investigate the use of three different novel MRI methods; Vascular, extracellular and restricted diffusion for cytometry in tumours (VERDICT), Luminal Imaging (LI) and hyperpolarised [1-13C]-pyruvate MRI (HYP-MRI). These scans help us to look at the microstructure as well as the metabolism of prostate tissue and may offer ways to better differentiate aggressive vs non-aggressive disease.
These scans will be performed in men with prostate cancer suitable for active surveillance at baseline and 1 year later to assess for prognostic indicators for progression in early prostate cancer.HYP-MRI will also be performed in men undergoing radical prostatectomy for validation of image findings and pathology. Whilst some men will have repeat scanning to asses for the repeatability of these techniques.
Visão geral do estudo
Status
Condições
Descrição detalhada
PURPOSE AND DESIGN
The purpose of this study is to assess the ability of novel MRI techniques and their derived metrics in the diagnosis and prognostication of prostate cancer. Improving the diagnostic accuracy and investigating biomarkers with non- invasive MRI techniques have the promise of reducing unnecessary biopsies or radical treatment, as well as detecting those likely to progress at an earlier stage.
Vascular, Extracellular and Restricted Cytometry in Tumours (VERDICT) MRI
Diffusion-weighted imaging (DWI) is one of the most important sequences in mp-MRI of the prostate which reflects the diffusivity of water in cells and differs in cancerous tumour due to changes in cellular density, size, shape and arrangement. VERDICT is a novel framework which uses a more complex 3-compartment tissue model for diffusion of water; 1. Water trapped in cells, 2. Water in the vascular network and 3. Interstitial water. This allows us to make estimates of specific tissue properties such as the size and packing density of the cells, the vascular extracellular- extravascular space (EES) volume fractions. This methods is more biologically specific compared to conventional DWI. Studies in tumour xenograft models of colorectal cancer showed its ability to detect such known differences in the microstructure. At UCL we have applied VERDICT to the prostates of 78 men and were able to successfully differentiate between benign or clinically insignificant cancer and clinically significant tumours. This technique can be applied on commercially available MRI scanners and requires no additional contrast agents or requirements for the patient compared to conventional mp-MRI of the prostate.
Luminal Index (LI) MRI
Using a multi-echo T2 sequence we can differentiate between the relatively long T2 values of the luminal space and the short T2 values of the stromal and epithelial cells to estimate the fractional volume of water in each MR voxel, the luminal water fraction (LWF). Studies have shown a good correlation between LWF and histologically measure luminal fractional volume and hence promise to detect prostate cancer and predict Gleason score. Our refined local LI MRI sequence has been very good at differentiating clinically significant and non-significant tumours. This technique also requires no additional contrast agents or patient requirements to be completed.
Hyperpolarised [1-13C]-pyruvate MRI (HYP-MRI)
Cancer cell rely on enhanced glycolysis for their energy supply, a phenomenon known as the Warburg effect. This is a key discriminator of malignancy and normal tissues and has been successfully targeted with well-established imaging techniques such as Fluorodeoxyglucose (FDG) - Positron Emission Tomography (PET). HYP-MRI is able to image a part of this metabolic process in real-time. An injectable solution containing 13C labelled pyruvate which is hyperpolarised onsite in order to increase the eventual detectable signal. The naturally occurring metabolise pyruvate is converted to lactate with the attached 13C tag persisting enabling us to track the presence and conversion of pyruvate to lactate after the injection. It heralds the potential to differentiate tumours which are more likely to grow and metastasise from those which won't. This sequence requires an additional injection compared to standard mp-MRI and also uses an endorectal coil which is place inside the rectum for the duration of the scan.
The main objectives of this study are as follow and are addressed in three sub-studies:
- To biologically validate HYP-MRI with correlation against biological measurements in men undergoing radical prostatectomy (BioVal: 44 patients)
- Clinical validation of novel MRI techniques (VERDICT/LI/HYP-MRI) derived measurements for differentiating patients with aggressive (progressive) and indolent (non-progressive) prostate cancer in men entering active surveillance (ProVal: 120 patients)
- Technical validation of novel MRI techniques (VERDICT/LI/HYP-MRI) through assessment of repeatability metrics from derived parameters (TecVal: 20 patients)
Tipo de estudo
Inscrição (Antecipado)
Contactos e Locais
Contato de estudo
- Nome: Adam Retter, MD
- Número de telefone: +044 7398762767
- E-mail: rhmaret@ucl.ac.uk
Estude backup de contato
- Nome: Trial Manager
- E-mail: ncita.validatepro@ucl.ac.uk
Locais de estudo
-
-
-
London, Reino Unido
- Recrutamento
- University College London
-
Contato:
- Adam Retter, MD
- Número de telefone: +044 7398762767
- E-mail: rmharet@ucl.ac.uk
-
-
Critérios de participação
Critérios de elegibilidade
Idades elegíveis para estudo
Aceita Voluntários Saudáveis
Gêneros Elegíveis para o Estudo
Método de amostragem
População do estudo
BioVal Cohort: Men scheduled for Prostatectomy
ProVal Cohort: Men initiating active surveillance and treatment for low grade disease.
Descrição
Inclusion Criteria:
- Men aged >18 years
- Pre-biopsy mp-MRI study performed within preceding 4 months
- Likert/PIRADS score 4-5/5 lesion and/or biopsy confirmed Prostate cancer
- Willing and able to provide written informed consent
Exclusion Criteria:
- Men who suffer with claustrophobia or are unable to have an MRI e.g. implantable defibrillator, brain aneurysm clips or other implant, severe obesity or unable to lay still for length of scan.
- Men with an impaired renal function (eGFR <30)
- Previous prostate radiotherapy/focal treatment
- Hormonal treatment for prostate cancer within preceding 3 months from consenting to the study.
- Dementia or other neurological condition meaning participant lacks the capacity to consent.
Plano de estudo
Como o estudo é projetado?
Detalhes do projeto
Coortes e Intervenções
Grupo / Coorte |
---|
BioVal
BioVal is a single site validation study to determine the histological correlates underpinning signals derived from 13C-pyruvate HYP-MRI in men with known prostate cancer scheduled for prostatectomy.
|
ProVal
ProVal is a single site, prospective, longitudinal observational cohort study to determine the prognostic value of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known early prostate cancer on active surveillance.
|
TecVal
TecVal is a multi-site validation study to determine the inter-site repeatability and intra-site reproducibility of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known prostate cancer.
|
O que o estudo está medindo?
Medidas de resultados primários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
ProVal Primary Objective
Prazo: 3 years
|
To determine the prognostic value of VERDICT metrics for risk classification of patients with early prostate cancer suitable for active surveillance. Quantitive value: fIC (intracellular (IC) volume fraction) among others within model. |
3 years
|
ProVal Primary Objective
Prazo: 3 years
|
To determine the prognostic value of Luminal Index for risk classification of patients with early prostate cancer suitable for active surveillance. Quantitive value: Luminal index |
3 years
|
ProVal Primary Objective
Prazo: 3 years
|
To determine the prognostic value of 13C-HYP-MRI for risk classification of patients with early prostate cancer suitable for active surveillance. Quantitive value: Lactate and pyruvate ratio parameters. |
3 years
|
BioVal Primary Objective
Prazo: 3 years
|
To estimate the association of 13C-HYP-MRI derived quantitative metrics against histological features of prostate cancer. Quantitive value: Lactate and pyruvate ratio parameters. |
3 years
|
BioVal Primary Objective
Prazo: 3 years
|
To estimate the association of 13C-HYP-MRI derived quantitative metrics against histological features of prostate cancer. Quantitive value: Gleason Grade |
3 years
|
TecVal Primary Objective
Prazo: 3 years
|
Inter-site repeatability and intra-site reproducibility of signals derived from VERDICT, Luminal Index MRI and 13C-pyruvate HYP-MRI in men with known prostate cancer. Metric: Repeatability and reproducibility co-efficients |
3 years
|
Medidas de resultados secundários
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
ProVal Secondary Objective
Prazo: 3 year
|
To examine the effects of histological progression of prostate cancer on VERDICT and LI-MRI quantitative metrics To determine whether baseline imaging metrics can predict time to radiological progression. Metric: Gleason grade (used in combination with previous metrics discussed) |
3 year
|
Outras medidas de resultado
Medida de resultado |
Descrição da medida |
Prazo |
---|---|---|
ProVal Tertiary Objective
Prazo: 3 years
|
To link quantitative mpMRI, VERDICT MRI, LI-MRI and 13C-HYP-MRI quantitative features with molecular, genetic, epigenetic, transcriptomic and proteomic immune measurements made within patients recruited to the linked RECONCILE study. Metric: genetic, molecular and epigenetic measurements. |
3 years
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: Shonit Punwani, MD PhD, UCL
Datas de registro do estudo
Datas Principais do Estudo
Início do estudo (Real)
Conclusão Primária (Antecipado)
Conclusão do estudo (Antecipado)
Datas de inscrição no estudo
Enviado pela primeira vez
Enviado pela primeira vez que atendeu aos critérios de CQ
Primeira postagem (Real)
Atualizações de registro de estudo
Última Atualização Postada (Real)
Última atualização enviada que atendeu aos critérios de controle de qualidade
Última verificação
Mais Informações
Termos relacionados a este estudo
Palavras-chave
Termos MeSH relevantes adicionais
Outros números de identificação do estudo
- 129237
Informações sobre medicamentos e dispositivos, documentos de estudo
Estuda um medicamento regulamentado pela FDA dos EUA
Estuda um produto de dispositivo regulamentado pela FDA dos EUA
Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .
Ensaios clínicos em Câncer de próstata
-
Turku University HospitalLounais-Suomen SyöpäyhdistysAinda não está recrutandoSobrevivente de cancerFinlândia
-
Roswell Park Cancer InstituteNational Cancer Institute (NCI)RetiradoSobrevivente de cancerEstados Unidos
-
University of Alabama at BirminghamNational Cancer Institute (NCI); Auburn UniversityConcluído
-
Rutgers, The State University of New JerseyNational Cancer Institute (NCI)ConcluídoSobrevivente de cancerEstados Unidos
-
Wake Forest University Health SciencesNational Cancer Institute (NCI)ConcluídoSobrevivente de cancerEstados Unidos, Guam
-
Wake Forest University Health SciencesNational Cancer Institute (NCI); National Institute of Mental Health (NIMH)ConcluídoSobrevivente de cancerEstados Unidos
-
Masonic Cancer Center, University of MinnesotaConcluídoSobrevivente de cancerEstados Unidos
-
Abramson Cancer Center of the University of PennsylvaniaConcluídoPlano de cuidados de sobrevivência LIVESTRONG: coleta contínua de dados e pesquisa de acompanhamentoPaciente com cancerEstados Unidos
-
University of New MexicoNew Mexico State University; University of New Mexico Cancer CenterConcluído
-
Ohio State University Comprehensive Cancer CenterConcluídoSobrevivente de cancerEstados Unidos