Using the Boneflo System During Orthopedic and Trauma Surgery: A Prospective Multicenter Study (BoneFlo)
Analysis of the Intraoperative Use and Handling of the Boneflo Tissue Collector System in Orthopedic and Trauma Surgery
Critical bone defects, non-unions, and delayed bone healing remain major challenges in orthopedic and trauma surgery and often require bone grafting. While a patient's own bone (autograft) is considered the gold standard, its use is limited by donor-site morbidity and limited availability. Synthetic bone substitutes offer an alternative but mainly provide structural support and lack biological activity.
This prospective multicenter pilot study evaluates the safety and feasibility of using the Boneflo® Tissue Collector System to biologically activate bone substitutes during surgery. The device collects the patient's own tissue, blood, and biologically active factors directly from the surgical site using a vacuum-assisted suction system with an integrated filter. This material is then used intraoperatively to coat and bioactivate bone substitute materials.
In healing attempts, 50 patients with critical bone defects, non-unions, or impaired bone healing were treated across four centers. Various bone substitutes, including synthetic calcium phosphate materials, collagen-based scaffolds, and allografts, were used.
The primary aim of the study was to evaluate device safety, intraoperative usability, handling, and applicability for coating and activating bone substitutes. The device was evaluated by orthopedic surgeons and other medical professionals, including nurses, physician assistants, and technical assistants.
Furthermore, these data were supplemented with clinical outcome data from healing attempts, including wound healing and radiographic bone regeneration, assessed over a minimum six-month follow-up period.
研究概览
地位
研究类型
注册 (实际的)
阶段
- 不适用
联系人和位置
学习地点
-
-
-
Mülheim、德国、45468
- St. Marien-Hospital Mülheim an der Ruhr
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
Patients with critical size bone defects, non-unions or delayed bone healing
Indication for bone grafting (autologous, allogeneic, or synthetic)
Age ≥ 18 years
Written informed consent obtained prior to surgery
Ability to comply with follow-up visits for at least 6 months
Exclusion Criteria:
Active local or systemic infection
Vertebral body defects (according to device instructions for use)
Active malignancy or tumor-related bone disease
Severe systemic disease affecting bone healing (e.g., autoimmune disease, immunodeficiency)
Contraindication to surgery or anesthesia
Inability or unwillingness to provide informed consent
学习计划
研究是如何设计的?
设计细节
- 主要用途:基础科学
- 分配:不适用
- 介入模型:单组作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
其他:Bioactivated Bone Substitutes Using a Surgical Suction Device
Synthetic bone substitutes were intraoperatively activated using autologous tissue in patients with critical bone defects, non-unions, and delayed bone healing.
During surgery, autologous tissue, blood, and biologically active components were collected from the surgical site under vacuum conditions using an integrated filter system.
The collected material was used to coat and biologically activate bone substitutes, including calcium phosphate ceramics, collagen-based scaffolds, and allografts.
The primary focus was on safety, intraoperative usability, handling, and applicability of the device for bone substitute bioactivation.
These data were combined with clinical outcomes in healing attempts, including wound healing and radiographic bone regeneration over a six-month follow-up period.
|
During surgery, autologous tissue, blood, and biologically active components are collected from the surgical site under vacuum conditions with an integrated filter system using the BoneFlo tissue collector.
The collected autologous material is used to coat and biologically enhance bone substitutes.
Bone substitutes include calcium phosphate ceramics, collagen-based scaffolds, and allografts.
This intervention is performed intraoperatively and aims to improve the biological activity of otherwise mainly osteoconductive materials.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Incidence of device-related adverse events (% of participants)
大体时间:Up to 30 days postoperatively
|
Assessment of safety of the surgical suction device used for intraoperative bioactivation of bone substitutes, measured by the number and proportion of participants experiencing device-related adverse events, as recorded in clinical evaluation and adverse event reporting.
|
Up to 30 days postoperatively
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Surgeon-reported usability score (Likert scale)
大体时间:Immediately after the procedure
|
Assessment of device applicability and handling using a standardized surgeon questionnaire with a Likert scale rating immediately after use.
|
Immediately after the procedure
|
|
Rate of successful intraoperative bioactivation procedures
大体时间:Intraoperatively (during the index surgical procedure)
|
Assessment of intraoperative feasibility based on successful completion of the procedure as judged by the operating surgeon.
The unit of measure is the percentage of procedures (% of procedures).
|
Intraoperatively (during the index surgical procedure)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (实际的)
研究完成 (实际的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.