- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07562165
Using the Boneflo System During Orthopedic and Trauma Surgery: A Prospective Multicenter Study (BoneFlo)
Analysis of the Intraoperative Use and Handling of the Boneflo Tissue Collector System in Orthopedic and Trauma Surgery
Critical bone defects, non-unions, and delayed bone healing remain major challenges in orthopedic and trauma surgery and often require bone grafting. While a patient's own bone (autograft) is considered the gold standard, its use is limited by donor-site morbidity and limited availability. Synthetic bone substitutes offer an alternative but mainly provide structural support and lack biological activity.
This prospective multicenter pilot study evaluates the safety and feasibility of using the Boneflo® Tissue Collector System to biologically activate bone substitutes during surgery. The device collects the patient's own tissue, blood, and biologically active factors directly from the surgical site using a vacuum-assisted suction system with an integrated filter. This material is then used intraoperatively to coat and bioactivate bone substitute materials.
In healing attempts, 50 patients with critical bone defects, non-unions, or impaired bone healing were treated across four centers. Various bone substitutes, including synthetic calcium phosphate materials, collagen-based scaffolds, and allografts, were used.
The primary aim of the study was to evaluate device safety, intraoperative usability, handling, and applicability for coating and activating bone substitutes. The device was evaluated by orthopedic surgeons and other medical professionals, including nurses, physician assistants, and technical assistants.
Furthermore, these data were supplemented with clinical outcome data from healing attempts, including wound healing and radiographic bone regeneration, assessed over a minimum six-month follow-up period.
Studienübersicht
Status
Studientyp
Einschreibung (Tatsächlich)
Phase
- Unzutreffend
Kontakte und Standorte
Studienorte
-
-
-
Mülheim, Deutschland, 45468
- St. Marien-Hospital Mülheim an der Ruhr
-
-
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
- Erwachsene
- Älterer Erwachsener
Akzeptiert gesunde Freiwillige
Beschreibung
Inclusion Criteria:
Patients with critical size bone defects, non-unions or delayed bone healing
Indication for bone grafting (autologous, allogeneic, or synthetic)
Age ≥ 18 years
Written informed consent obtained prior to surgery
Ability to comply with follow-up visits for at least 6 months
Exclusion Criteria:
Active local or systemic infection
Vertebral body defects (according to device instructions for use)
Active malignancy or tumor-related bone disease
Severe systemic disease affecting bone healing (e.g., autoimmune disease, immunodeficiency)
Contraindication to surgery or anesthesia
Inability or unwillingness to provide informed consent
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Grundlegende Wissenschaft
- Zuteilung: N / A
- Interventionsmodell: Einzelgruppenzuweisung
- Maskierung: Keine (Offenes Etikett)
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Sonstiges: Bioactivated Bone Substitutes Using a Surgical Suction Device
Synthetic bone substitutes were intraoperatively activated using autologous tissue in patients with critical bone defects, non-unions, and delayed bone healing.
During surgery, autologous tissue, blood, and biologically active components were collected from the surgical site under vacuum conditions using an integrated filter system.
The collected material was used to coat and biologically activate bone substitutes, including calcium phosphate ceramics, collagen-based scaffolds, and allografts.
The primary focus was on safety, intraoperative usability, handling, and applicability of the device for bone substitute bioactivation.
These data were combined with clinical outcomes in healing attempts, including wound healing and radiographic bone regeneration over a six-month follow-up period.
|
During surgery, autologous tissue, blood, and biologically active components are collected from the surgical site under vacuum conditions with an integrated filter system using the BoneFlo tissue collector.
The collected autologous material is used to coat and biologically enhance bone substitutes.
Bone substitutes include calcium phosphate ceramics, collagen-based scaffolds, and allografts.
This intervention is performed intraoperatively and aims to improve the biological activity of otherwise mainly osteoconductive materials.
|
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Incidence of device-related adverse events (% of participants)
Zeitfenster: Up to 30 days postoperatively
|
Assessment of safety of the surgical suction device used for intraoperative bioactivation of bone substitutes, measured by the number and proportion of participants experiencing device-related adverse events, as recorded in clinical evaluation and adverse event reporting.
|
Up to 30 days postoperatively
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
Surgeon-reported usability score (Likert scale)
Zeitfenster: Immediately after the procedure
|
Assessment of device applicability and handling using a standardized surgeon questionnaire with a Likert scale rating immediately after use.
|
Immediately after the procedure
|
|
Rate of successful intraoperative bioactivation procedures
Zeitfenster: Intraoperatively (during the index surgical procedure)
|
Assessment of intraoperative feasibility based on successful completion of the procedure as judged by the operating surgeon.
The unit of measure is the percentage of procedures (% of procedures).
|
Intraoperatively (during the index surgical procedure)
|
Mitarbeiter und Ermittler
Sponsor
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Tatsächlich)
Primärer Abschluss (Tatsächlich)
Studienabschluss (Tatsächlich)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Zusätzliche relevante MeSH-Bedingungen
Andere Studien-ID-Nummern
- BO/35/2025-Studie-01 (Andere Kennung: Ärztekammer Niedersachsen (Ethics Committee))
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .