此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Accuracy of Positioning Guide and Customized Plate in Zygomaticomaxillary Complex Fracture

2026年11月1日 更新者:Abdellatif Saad Abdellatif Nawar、Cairo University

Accuracy of Positioning Guide and Customized Titanium Plate for Reduction and Fixation of Zygomaticomaxillary Complex Fracture: A Case Series

This prospective, single-arm case series aims to evaluate the accuracy of a virtual planning-based positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures.

The primary objective is to assess fracture reduction accuracy by comparing postoperative CT findings with the preoperative virtual surgical plan. Secondary objectives are to evaluate fixation stability and patient satisfaction.

Participants undergo preoperative CT imaging for virtual surgical planning, followed by surgical reduction and fixation using a patient-specific positioning guide and customized titanium plate. Postoperative CT imaging is used to assess reduction accuracy, with subsequent follow-up to evaluate fixation stability and patient satisfaction.

研究概览

详细说明

The study evaluates the accuracy of a patient-specific positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures.

All patients undergo a thorough medical and dental history and comprehensive clinical examination. Clinical measurements and photographic documentation are obtained to assess facial symmetry, ocular function, and mouth opening. A preoperative computed tomography (CT) scan (T0) is obtained within one week before surgery to assess the fracture pattern and the extent of displacement. The Digital Imaging and Communications in Medicine (DICOM) data are imported into specialized medical imaging software (e.g., Mimics, 3-matic, or equivalent) for three-dimensional reconstruction and virtual surgical planning (VSP).

During the virtual planning phase, the fractured zygomaticomaxillary complex is first virtually reduced by mirroring the unaffected contralateral side to establish the planned anatomical position. If mirroring is not feasible, established anatomical landmarks and anatomical norms are used to guide the virtual reduction. The customized titanium plate is then designed on the virtually reduced model to fit the planned bone contours. The screw positions and trajectories are also planned, and the screws are virtually positioned within their corresponding fracture segments to define the intended fixation configuration.

After finalizing the plate and screw design in the reduced position, the zygomatic complex is virtually returned to its original displaced fracture position while maintaining the planned screw positions relative to their respective bone segments. The patient-specific positioning guide is then designed on this unreduced model. The guide incorporates the planned drilling locations, allowing the screw holes to be predrilled in the original fracture position. These predrilled holes subsequently guide the reduction and allow the customized plate to be positioned and fixed according to the original virtual surgical plan.

The customized titanium plate is designed using computer-aided design (CAD) and manufactured using computer-aided manufacturing (CAM). The design is exported in STL format, and machining programs are generated for production. The plate is fabricated from medical-grade Titanium Grade 4 using a three-axis CNC milling machine (MILLSTAR, Taiwan), through a subtractive manufacturing process. The machined plate undergoes deburring, polishing, anodizing, cleaning, and packing before use. Digital planning and fabrication are performed by Arab Engineers for Designs and Medical Instrumentation in collaboration with the research team.

Surgical treatment is performed under general anesthesia using lateral eyebrow and intraoral vestibular incisions to expose the fracture site. The patient-specific positioning guide is placed on the zygomatic complex in its original displaced fracture position. The planned screw holes are predrilled through the guide. After removal of the guide, the fracture segments are reduced using the predrilled holes as references to reproduce the planned anatomical position. The customized titanium plate is then positioned according to the planned screw positions and secured with screws to achieve fixation. The surgical site is irrigated and the incisions are closed in layers.

A postoperative CT scan (T1) is obtained within one week after surgery to assess the accuracy of fracture reduction and plate placement. The preoperative virtual surgical plan and postoperative CT model are imported into imaging software and superimposed. Linear and angular deviations between the planned and achieved positions of anatomical landmarks and plate positions are measured in millimeters and degrees. Measurements are performed by the researcher and verified by the main supervisor.

Clinical follow-up is conducted at 1 week, 1 month, 3 months, 6 months to assess wound healing, facial symmetry, ocular function, mouth opening, and postoperative complications, including infection, nerve paresthesia, malunion, and non-union. A follow-up CT scan (T2) is planned at 6 months to evaluate bone healing and fixation stability, including any signs of loosening or displacement. Patient satisfaction is assessed using a Visual Analog Scale (VAS) ranging from 0 to 10.

研究类型

介入性

注册 (估计的)

8

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

      • Cairo、埃及
        • department of oral and maxillofacial surgery, faculty of dentistry, Cairo university

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Patients diagnosed with Zygomatico-maxillary complex fractures requiring surgical intervention.
  • Patients aged 18 years or older.
  • Patients willing to provide informed consent and comply with follow-up protocols.
  • Patients with adequate bone quality and quantity for stable fixation.

Exclusion Criteria:

  • Patients with comminuted ZMC fractures that preclude the use of custom-made guides based on mirroring the contra lateral side.
  • Patients with pre-existing facial deformities or asymmetries that would interfere with accurate assessment of fracture reduction.
  • Patients with systemic diseases or conditions that contraindicate elective surgery or impair bone healing (e.g., uncontrolled diabetes, severe osteoporosis, active malignancy, and immunosuppression).
  • Patients on medications affecting bone metabolism (e.g., long-term corticosteroids, bisphosphonates). Patients with active infections in the maxillofacial region.
  • Pregnant or lactating women.
  • Patients with psychiatric disorders or unrealistic expectations.
  • Patients who are unable to undergo CT scans or follow post-operative instructions.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Virtual Planning and Customized Plates

Patients with ZMC fractures undergoing surgical treatment using 3D virtual planning and patient-specific titanium plates.

A 3D-printed positioning guide designed through virtual surgical planning to assist in the accurate reduction of ZMC fractures.

其他名称:
  • positioning guide

A custom-fabricated titanium plate designed to fit the patient's specific anatomy for rigid fixation of ZMC fractures.

其他名称:
  • customised plate

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Accuracy of Fracture Reduction
大体时间:one week postoperative

Evaluation of the accuracy of fracture reduction achieved using the positioning guide and customized titanium plate. This will be assessed by superimposing the post-operative computed tomography (CT) scans onto the pre-operative virtual surgical plan. The difference will be reported as linear deviation, measured in millimeters (mm).

one week postoperative

次要结果测量

结果测量
措施说明
大体时间
Fixation stability
大体时间:6 months postoperatively

Measured in millimeters by comparing the 6-month follow-up CT to the immediate postoperative CT to check for hardware or bone displacement.

6 months postoperatively
Patient satisfaction
大体时间:6 months postoperatively

Evaluation of the patient's overall satisfaction with the functional and aesthetic outcomes of the procedure. This will be assessed using a Visual Analog Scale (VAS) ranging from 0 to 10, where 0 indicates "completely dissatisfied" and 10 indicates "completely satisfied". The reported value will be the numerical score on this scale

6 months postoperatively

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Prof. Ramy Ragab Elbialy, prof. of maxillofacial surgery、Department of Oral and maxillofacial surgery,Faculty of dentistry, Cairo university
  • 研究主任:Dr. Mohamed Ali Zain Elabden, lecturer of maxillofacial surg、Department of Oral and maxillofacial surgery, Faculty of dentistry, Cairo university

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2025年12月18日

初级完成 (估计的)

2026年12月1日

研究完成 (估计的)

2027年9月1日

研究注册日期

首次提交

2026年4月29日

首先提交符合 QC 标准的

2026年5月19日

首次发布 (实际的)

2026年5月27日

研究记录更新

最后更新发布 (实际的)

2026年11月4日

上次提交的符合 QC 标准的更新

2026年11月1日

最后验证

2026年11月1日

更多信息

与本研究相关的术语

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅