Feasibility and Safety of Augmented Reality (AR) in Liver Tumor Surgery

2026年6月1日 更新者:Navari Surgical AB

Feasibility and Safety of Augmented Reality (AR) Assistance System in Liver Tumor Surgery - a Single-center, Exploratory, Pilot Study

The purpose of the trial is to evaluate a computer-based Augmented Reality System intended to help surgeons perform keyhole surgery (laparoscopy) for the removal of liver tumors more efficiently and with greater patient safety.

In keyhole surgery, the operation is performed using a small camera that is inserted into the abdominal cavity of the patient through surgical trocars placed through small incisions in the skin. The surgeon then performs the operation by guidance from the view from the camera, which shows the surgical area, i.e. the liver and the inside of the abdomen, on a screen in front of them.

The clinical trial will evaluate a computer-based system that uses a technology known as augmented reality, or AR. In simple terms, this is a technology that superimposes a computer-generated image on a user's view of the real world, thus providing a composite view. In this case, a computer program will integrate an image showing the tumor's appearance and position inside the liver into the live video feed from the camera, which is then displayed on the existing TV screen, connected to the keyhole camera.

Put simply, the AR-projection will appear as an illustrated overlay on the surface of the liver, showing the appearance and position of the tumor throughout the procedure. This may give the surgeon and operating room staff a better understanding of the tumor's location, helping them perform the procedure more safely, accurately and efficiently.

To help the computer-based system with positioning of the illustrated overlay correctly on the liver, a small self-adhesive plastic marker, measuring 11x11 mm, will be placed on the surface of the liver while the operation is being carried out. The marker is inserted through the surgical trocars already placed in the abdominal cavity and will be removed from the body before the operation is completed.

The purpose of the clinical trial is to assess whether this new technology can help achieve greater accuracy, increased patient safety and a more efficient surgical workflow when tumors in the liver are removed using keyhole surgery. A total of 6 participants will be included in the trial.

The clinical trial has been approved by the Swedish Medical Products Agency following an opinion from the Swedish Ethical Review Authority.

研究概览

详细说明

Cancer is the second-leading global health threat, accounting for approximately 18% of fatalities worldwide and leading to 10 million deaths each year. In addition, in 2020, 19.3 million people were diagnosed with some type of cancer worldwide and the cumulative risk of getting cancer was as high as 39.6%.

About 60% of cancer patients will require surgical intervention to remove the tumor at some point in their treatment pathway.

In the past few decades, laparoscopic minimally invasive surgery (LMIS) has gained traction across various medical specialties, including oncology. This technique has consistently demonstrated improved postoperative outcomes compared with open surgery.

The Navari System is a visualization tool for minimally invasive liver surgery, which will give the operator a visualization of the tumor's position under the tissue surface in real time during the surgical procedure. The system utilizes the video feed from the minimally invasive camera to provide the operator with an augmented reality (AR) overlay of the tumor. The AR-overlay is created from patient-specific x-ray data, provided in real-time during the surgical procedure, and is shown as an integrated part of the video feed from the minimally invasive camera. To provide the operator with depth perception, the system will provide two views simultaneously, one from the camera angle and one additional view from another angle selected through the Navari user interface.

The rationale for this clinical investigation is to evaluate safety and performance of the Navari System, in its initial clinical application, minimally invasive liver tumor surgical resection.

研究类型

介入性

注册 (估计的)

6

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

研究联系人备份

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  1. Subject scheduled for liver tumor resection of one or more tumors. One tumor per surgery is always chosen as the study tumor and will be removed first.
  2. The tumor must be susceptible to uncomplicated wedge resection within one to two segments.
  3. The tumor has been diagnosed as malignant or is suspected to be malignant based on imaging or clinical assessment.
  4. The tumor's size should not exceed 50 mm in any orientation.
  5. Subject 18 years or older.
  6. Subject is able to read and understand the Patient information which is written in Swedish.
  7. Subject has given consent to study participation.

Exclusion Criteria:

  1. Unresectable tumors.
  2. Not uncomplicated resection (e.g. central resection, re-resection, or large resection, defined as resection of more than two segments).
  3. Subject is not suitable for MIS, as judged by the principal investigator.
  4. Subject with reduced kidney function.
  5. Subject with known hypersensitivity to contrast agents.
  6. Subject considered unable to comply with hospital's instructions, at the discretion of the principal investigator.
  7. Subject is not suitable for inclusion in the opinion of the investigator.
  8. Pregnant women.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:设备可行性
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Augmented reality in liver tumor surgery
The Navari System provides surgeons and healthcare professionals with Augmented Reality (AR) guidance in real-time during minimally invasive liver surgery. A patient-specific tumor model is created from Cone Beam Computed Tomography (CBCT) data and presented in AR-format as an integrated part of the video feed from the minimally invasive camera. The AR-overlay communicates the tumor's position inside the liver in real-time during surgery, supporting the surgeon with intraoperative decision-making, increasing surgical precision, and minimizing the risk of incomplete tumor removal.
This is a first-in-human, clinical trial, using the augmented reality system developed by Navari Surgical
This is the first-in-human, clinical trial, for using the augmented reality system in patients undergoing minimally invasive liver surgery for the removal of liver tumors.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Number of radical resections and evaluation of resected tumor margins.
大体时间:5 weeks
The augmented reality system's ability to assist surgeons in achieving radical tumor resections (i.e. the resected tumor has a margin larger than 0 mm). The number of radical resections is recorded, and the system's predicted margin of 10 mm is compared with the resected tumor margin determined by pathological examination.
5 weeks

次要结果测量

结果测量
措施说明
大体时间
Time to complete resection of the tumor.
大体时间:Day 0
Time for complete resection of the tumor, from the point at which the surgeon starts the resection to the point at which the tumor is removed from the liver parenchyma.
Day 0
Time for total procedure using the augmented reality system.
大体时间:Day 0
Time for the total procedure using the Navari System, from when the Navari Landmark is placed on the liver surface to when the tumor is removed from the liver parenchyma.
Day 0
Time for total surgical procedure
大体时间:Day 0
Time for total procedure, from the first incision for applying the trocar to the last incision is closed.
Day 0

其他结果措施

结果测量
措施说明
大体时间
Safety endpoints
大体时间:Through study completion, an avarage of 5 weeks
Safety endpoint(s): Number and description of Adverse Event (AE), Number of Adverse Device Effect (ADE), Number of Serious Adverse Event (SAE) Serious Adverse Device Effect (SADE) and Device Deficiency (DD).
Through study completion, an avarage of 5 weeks

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Svein Olav Bratlie, MD, PhD、Department of Surgery, Sahlgrenska University Hospital, Gothenburg, Sweden

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年6月1日

初级完成 (估计的)

2027年2月1日

研究完成 (估计的)

2027年2月1日

研究注册日期

首次提交

2026年5月27日

首先提交符合 QC 标准的

2026年6月1日

首次发布 (实际的)

2026年6月5日

研究记录更新

最后更新发布 (实际的)

2026年6月5日

上次提交的符合 QC 标准的更新

2026年6月1日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

其他研究编号

  • NAV-001
  • CIV-25-09-054620 (其他标识符:Swedish Medical Products Agency)

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.