此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Effects of Oxygen Cage Support During Cataract Surgery

2026年6月23日 更新者:Zeynep Kaya Pehlivan、Ataturk University

The Effect of Oxygen Support Cage Material Use During Cataract Surgery on Operation Time, Anxiety, Physiological Parameters, and Patient Experiences: A Mixed Methods Study

Cataract is an ocular disorder resulting from lens opacity; it stands as the most common cause of preventable blindness worldwide and significantly impairs the quality of life in elderly individuals. Surgical treatment utilizing small-incision phacoemulsification is the most effective solution for cataracts. Cataract surgery is generally performed under local anesthesia, which requires patients to remain awake throughout the operation, thereby potentially increasing their anxiety experiences. Elevated anxiety not only reduces patient comfort but can also lead to alterations in physiological parameters and a prolongation of the operation time. Furthermore, it is observed that the surgical drapes used to maintain the sterility of the surgical field during the operation cause discomfort to the patient. The weight and positioning of these drapes can cover the patient's mouth and nose area during the ongoing surgery, creating a sensation of difficulty in breathing (dyspnea). In addition to these circumstances, standard oxygen support is provided to the patient during cataract surgery performed under local anesthesia. This support is administered nasally via an open-ended oxygen tubing from beneath the surgical drape, aiming to ease the patient's respiration. However, when the oxygen flow rate is increased based on the patient's needs, high-velocity and high-concentration oxygen administration is observed to cause mucosal dryness, which shortly triggers reflex-induced irritative coughing attacks. For these reasons, it is crucial to keep anxiety under control, provide oxygen to prevent hypoxia, and monitor physiological parameters during cataract surgery.

研究概览

地位

尚未招聘

条件

详细说明

This study is designed as a mixed-methods research project comprising two distinct but interconnected phases. The quantitative phase utilizes a randomized controlled experimental design to evaluate the physiological and clinical efficacy of a newly developed Oxygen Support Cage material. The qualitative phase employs a descriptive phenomenological approach to explore patients' in-depth subjective experiences, comfort levels, and perceptions regarding the device.

Patients assigned to the intervention group will undergo cataract surgery with the integration of the 3D-printed, biocompatible Oxygen Support Cage. This device is positioned over the patient's head area to elevate the sterile surgical drapes, effectively preventing direct contact and weight pressure on the patient's face, mouth, and nose. Concurrently, supplemental oxygen will be delivered into the cage micro-environment. This setup aims to maintain an optimal, stable oxygen concentration without high-velocity nasal flow, thereby mitigating mucosal dryness and potential cough reflexes. Patients assigned to the control group will receive the standard hospital protocol for cataract surgery, where supplemental oxygen is administered nasally via open-ended oxygen tubing beneath standard surgical drapes without any cage support.

Physiological parameters (including blood pressure, heart rate, respiratory rate, oxygen saturation, and end-tidal carbon dioxide [EtCO2]) will be monitored and recorded chronologically at predefined intervals: 15 minutes before descending to the operating room (in the patient room), during specific intraoperative stages, and postoperatively in the recovery room. Anxiety levels and surgical durations will be documented accordingly.

Following the completion of the surgical procedures and quantitative data collection, a subset of participants from the intervention group will be invited to participate in semi-structured, face-to-face qualitative interviews. These interviews will focus on their sensory experiences, breathing comfort, confinement anxiety under the drapes, and overall satisfaction with the Oxygen Support Cage. By combining statistical findings with thematic analysis of patient narratives, the study aims to provide a holistic validation of the medical device's utility in clinical practice.

研究类型

介入性

注册 (估计的)

70

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria

  • Willing to participate in the study voluntarily and provides informed consent
  • Aged 18 years or older
  • Having no hearing or cognitive impairments
  • Undergoing cataract surgery for the first time Exclusion Criteria
  • Conversion from local anesthesia to general anesthesia during the surgery
  • Patient's non-participation or refusal to complete the anxiety assessment during the surgery

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:支持治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:单身的

武器和干预

参与者组/臂
干预/治疗
实验性的:Oxygen Support Cage Group
Participants in this arm will undergo cataract surgery with the integration of a newly developed, 3D-printed, biocompatible Oxygen Support Cage. This medical device is placed over the patient's head to elevate the sterile surgical drapes, preventing them from exerting weight pressure or making direct contact with the patient's face, mouth, and nose. Supplemental oxygen is delivered directly into the cage micro-environment to ensure stable, high-concentration oxygenation. This setup aims to prevent mucosal dryness and irritative cough reflexes while reducing drape-induced anxiety and dyspnea.

This intervention utilizes a uniquely structured, 3D-printed, and biocompatible Oxygen Support Cage designed specifically for patients undergoing cataract surgery under local anesthesia. Unlike standard clinical procedures where surgical drapes lay directly on the patient's face and supplemental oxygen is administered via high-velocity nasal tubing, this device acts as a physical barrier. It is positioned over the patient's head to lift the weight of the sterile drapes completely off the mouth and nose area, thereby eliminating drape-induced physical pressure, a sense of confinement, and dyspnea.

Concurrently, the device features a specialized design that allows supplemental oxygen to be delivered directly into the cage micro-environment. This setup eliminates the need for direct nasal cannulas, preventing high-velocity airflow from causing mucosal dryness and subsequent iritative cough reflexes during crucial microscopic surgical steps. This dual-action approach simultaneously addres

无干预:Control Group: Standard Care
Participants in this arm will receive the standard hospital protocol for cataract surgery under local anesthesia. Supplemental oxygen will be administered nasally via standard open-ended oxygen tubing placed directly beneath the conventional surgical drapes. No cage support or drape-elevating device will be used; the sterile surgical drapes will rest directly over the patient's face as per routine clinical practice.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Changes in End-Tidal Carbon Dioxide
大体时间:Intraoperatively (at the 5th, 10th, 15th, 20th, and 25th minutes of the surgery).
Evaluates intraoperative ventilation status. Measurements are performed using the gas module of the GE Datex Ohmeda S Avance anesthesia machine. (Note: This parameter is only measured intraoperatively)
Intraoperatively (at the 5th, 10th, 15th, 20th, and 25th minutes of the surgery).
Changes in Anxiety Level Evaluated by State-Trait Anxiety Inventory (STAI-S)
大体时间:Baseline (15 minutes pre-operation) and postoperatively (5 minutes after transfer back to the patient room)
Evaluates the patient's pre-operative and post-operative situational anxiety levels using the State-Trait Anxiety Inventory (STAI-S). The scale score ranges from 20 to 80, where higher scores indicate higher levels of anxiety.
Baseline (15 minutes pre-operation) and postoperatively (5 minutes after transfer back to the patient room)
Changes in Anxiety Level Evaluated by Visual Analog Scale for Anxiety (VAS-A)
大体时间:Baseline (15 minutes pre-operation), intraoperatively (at the 15th minute of the surgery), and postoperatively (5 minutes after transfer back to the patient room).

Evaluates the patient's anxiety levels across perioperative, intraoperative, and postoperative phases using the Visual Analog Scale for Anxiety (VAS-A). The scale ranges from 0 to 10, where 0 indicates no anxiety and 10 indicates the worst possible anxiety.

Preoperative: Baseline measurement in the patient room.

Intraoperative: Real-time anxiety assessment under the surgical drapes at the 15th minute of cataract surgery without disrupting the sterile field.

Postoperative: Assessment in the patient room after transfer.

Baseline (15 minutes pre-operation), intraoperatively (at the 15th minute of the surgery), and postoperatively (5 minutes after transfer back to the patient room).
Changes in Systolic and Diastolic Blood Pressure
大体时间:Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)
Evaluates perioperative and intraoperative hemodynamic stability. Measurements are performed using the cardiac monitoring unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)
Changes in Respiratory Rate
大体时间:Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room).
Evaluates perioperative and intraoperative respiratory stability. Measurements are performed using the gas module/monitoring of the anesthesia machine during surgery, and a portable monitor postoperatively.
Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room).
Changes in Heart Rate
大体时间:Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)
Evaluates perioperative and intraoperative cardiac stability. Measurements are performed using the cardiac monitoring unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)
Changes in Oxygen Saturation
大体时间:Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)
Evaluates perioperative and intraoperative peripheral oxygenation levels. Measurements are performed using the pulse oximetry unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
Baseline (15 minutes pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th minute), and postoperatively (5 minutes after transfer to room)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年7月1日

初级完成 (估计的)

2027年5月1日

研究完成 (估计的)

2027年5月1日

研究注册日期

首次提交

2026年5月20日

首先提交符合 QC 标准的

2026年6月2日

首次发布 (实际的)

2026年6月8日

研究记录更新

最后更新发布 (实际的)

2026年6月26日

上次提交的符合 QC 标准的更新

2026年6月23日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • ZKP_ATAUNI_001
  • Ataturk Unıversity (其他标识符:Ataturk Unıversity)

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅