Effects of Oxygen Cage Support During Cataract Surgery
The Effect of Oxygen Support Cage Material Use During Cataract Surgery on Operation Time, Anxiety, Physiological Parameters, and Patient Experiences: A Mixed Methods Study
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
This study is designed as a mixed-methods research project comprising two distinct but interconnected phases. The quantitative phase utilizes a randomized controlled experimental design to evaluate the physiological and clinical efficacy of a newly developed Oxygen Support Cage material. The qualitative phase employs a descriptive phenomenological approach to explore patients' in-depth subjective experiences, comfort levels, and perceptions regarding the device.
Patients assigned to the intervention group will undergo cataract surgery with the integration of the 3D-printed, biocompatible Oxygen Support Cage. This device is positioned over the patient's head area to elevate the sterile surgical drapes, effectively preventing direct contact and weight pressure on the patient's face, mouth, and nose. Concurrently, supplemental oxygen will be delivered into the cage micro-environment. This setup aims to maintain an optimal, stable oxygen concentration without high-velocity nasal flow, thereby mitigating mucosal dryness and potential cough reflexes. Patients assigned to the control group will receive the standard hospital protocol for cataract surgery, where supplemental oxygen is administered nasally via open-ended oxygen tubing beneath standard surgical drapes without any cage support.
Physiological parameters (including blood pressure, heart rate, respiratory rate, oxygen saturation, and end-tidal carbon dioxide [EtCO2]) will be monitored and recorded chronologically at predefined intervals: 15 minutes before descending to the operating room (in the patient room), during specific intraoperative stages, and postoperatively in the recovery room. Anxiety levels and surgical durations will be documented accordingly.
Following the completion of the surgical procedures and quantitative data collection, a subset of participants from the intervention group will be invited to participate in semi-structured, face-to-face qualitative interviews. These interviews will focus on their sensory experiences, breathing comfort, confinement anxiety under the drapes, and overall satisfaction with the Oxygen Support Cage. By combining statistical findings with thematic analysis of patient narratives, the study aims to provide a holistic validation of the medical device's utility in clinical practice.
Tipo di studio
Iscrizione (Stimato)
Fase
- Non applicabile
Contatti e Sedi
Contatto studio
- Nome: Zeynep KAYA PEHLİVAN, Lecturer
- Numero di telefono: 05073404051
- Email: z.y.n.p04@hotmail.com
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
- Adulto
- Adulto più anziano
Accetta volontari sani
Descrizione
Inclusion Criteria
- Willing to participate in the study voluntarily and provides informed consent
- Aged 18 years or older
- Having no hearing or cognitive impairments
- Undergoing cataract surgery for the first time Exclusion Criteria
- Conversion from local anesthesia to general anesthesia during the surgery
- Patient's non-participation or refusal to complete the anxiety assessment during the surgery
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Terapia di supporto
- Assegnazione: Randomizzato
- Modello interventistico: Assegnazione parallela
- Mascheramento: Separare
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: Oxygen Support Cage Group
Participants in this arm will undergo cataract surgery with the integration of a newly developed, 3D-printed, biocompatible Oxygen Support Cage.
This medical device is placed over the patient's head to elevate the sterile surgical drapes, preventing them from exerting weight pressure or making direct contact with the patient's face, mouth, and nose.
Supplemental oxygen is delivered directly into the cage micro-environment to ensure stable, high-concentration oxygenation.
This setup aims to prevent mucosal dryness and irritative cough reflexes while reducing drape-induced anxiety and dyspnea.
|
This intervention utilizes a uniquely structured, 3D-printed, and biocompatible Oxygen Support Cage designed specifically for patients undergoing cataract surgery under local anesthesia. Unlike standard clinical procedures where surgical drapes lay directly on the patient's face and supplemental oxygen is administered via high-velocity nasal tubing, this device acts as a physical barrier. It is positioned over the patient's head to lift the weight of the sterile drapes completely off the mouth and nose area, thereby eliminating drape-induced physical pressure, a sense of confinement, and dyspnea. Concurrently, the device features a specialized design that allows supplemental oxygen to be delivered directly into the cage micro-environment. This setup eliminates the need for direct nasal cannulas, preventing high-velocity airflow from causing mucosal dryness and subsequent iritative cough reflexes during crucial microscopic surgical steps. This dual-action approach simultaneously addres |
|
Nessun intervento: Control Group: Standard Care
Participants in this arm will receive the standard hospital protocol for cataract surgery under local anesthesia.
Supplemental oxygen will be administered nasally via standard open-ended oxygen tubing placed directly beneath the conventional surgical drapes.
No cage support or drape-elevating device will be used; the sterile surgical drapes will rest directly over the patient's face as per routine clinical practice.
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Changes in Systolic and Diastolic Blood Pressure
Lasso di tempo: Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
Evaluates perioperative and intraoperative hemodynamic stability.
Measurements are performed using the cardiac monitoring unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
|
Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
|
Changes in Respiratory Rate
Lasso di tempo: Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
Evaluates perioperative and intraoperative respiratory stability.
Measurements are performed using the gas module/monitoring of the anesthesia machine during surgery, and a portable monitor postoperatively.
|
Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
|
Changes in Heart Rate
Lasso di tempo: Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
Evaluates perioperative and intraoperative cardiac stability.
Measurements are performed using the cardiac monitoring unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
|
Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
|
Changes in Oxygen Saturation
Lasso di tempo: Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
Evaluates perioperative and intraoperative peripheral oxygenation levels.
Measurements are performed using the pulse oximetry unit of the anesthesia machine during surgery, and a portable monitor postoperatively.
|
Baseline (15 min pre-operation), intraoperatively (at 5th, 10th, 15th, 20th, 25th min), and postoperatively (5 min after transfer to room).
|
|
Changes in End-Tidal Carbon Dioxide
Lasso di tempo: Intraoperatively (at the 5th, 10th, 15th, 20th, and 25th minutes of the surgery).
|
Evaluates intraoperative ventilation status.
Measurements are performed using the gas module of the GE Datex Ohmeda S Avance anesthesia machine.
(Note: This parameter is only measured intraoperatively)
|
Intraoperatively (at the 5th, 10th, 15th, 20th, and 25th minutes of the surgery).
|
|
Changes in Anxiety Level Evaluated by State-Trait Anxiety Inventory (STAI-S)
Lasso di tempo: Baseline (15 minutes pre-operation) and postoperatively (5 minutes after transfer back to the patient room)
|
Evaluates the patient's pre-operative and post-operative situational anxiety levels using the State-Trait Anxiety Inventory (STAI-S).
The scale score ranges from 20 to 80, where higher scores indicate higher levels of anxiety.
|
Baseline (15 minutes pre-operation) and postoperatively (5 minutes after transfer back to the patient room)
|
|
Changes in Anxiety Level Evaluated by Visual Analog Scale for Anxiety (VAS-A)
Lasso di tempo: Baseline (15 minutes pre-operation), intraoperatively (at the 15th minute of the surgery), and postoperatively (5 minutes after transfer back to the patient room).
|
Evaluates the patient's anxiety levels across perioperative, intraoperative, and postoperative phases using the Visual Analog Scale for Anxiety (VAS-A). The scale ranges from 0 to 10, where 0 indicates no anxiety and 10 indicates the worst possible anxiety. Preoperative: Baseline measurement in the patient room. Intraoperative: Real-time anxiety assessment under the surgical drapes at the 15th minute of cataract surgery without disrupting the sterile field. Postoperative: Assessment in the patient room after transfer. |
Baseline (15 minutes pre-operation), intraoperatively (at the 15th minute of the surgery), and postoperatively (5 minutes after transfer back to the patient room).
|
Collaboratori e investigatori
Sponsor
Pubblicazioni e link utili
Pubblicazioni generali
- Guan GQ, Lin XD, Bao JL, Zhou XZ. Effect of cervical pillow in phacoemulsification surgery for age-related cataract patients: a prospective randomized controlled study. Int Ophthalmol. 2024 Jun 11;44(1):232. doi: 10.1007/s10792-024-03090-0.
- Yenigun SC, Demir Korkmaz F. The Effects of Stress Ball Practice on Patient Anxiety, Pain and Vital Signs During Cataract Surgery: A Randomized Controlled Trial. Pain Manag Nurs. 2025 Oct;26(5):592-599. doi: 10.1016/j.pmn.2025.04.009. Epub 2025 May 20.
Studiare le date dei record
Studia le date principali
Inizio studio (Stimato)
Completamento primario (Stimato)
Completamento dello studio (Stimato)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Effettivo)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Parole chiave
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- ZKP_ATAUNI_001
- Ataturk Unıversity (Altro identificatore: Ataturk Unıversity)
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .
Prove cliniche su Cataratta
-
RxSight, Inc.Iscrizione su invito
-
Adaptilens, Inc.Non ancora reclutamentoAphakia Cataract
Prove cliniche su Oxygen Support Cage
-
Xijing HospitalAttivo, non reclutanteMalattia sintomatica del disco cervicaleCina
-
The Affiliated Hospital of Qingdao UniversityPeking University People's Hospital; The First Affiliated Hospital of Zhengzhou... e altri collaboratoriNon ancora reclutamentoErnia del disco lombare | Stenosi spinale lombare | Spondilolistesi lombare | Scoliosi lombare degenerativa
-
Conventus Orthopaedics, Inc.TerminatoFratture omerali, prossimaliStati Uniti
-
Medtronic Spinal and BiologicsCompletato
-
Conventus Orthopaedics, Inc.TerminatoFrattura prossimale dell'omeroStati Uniti
-
Denver Health and Hospital AuthorityNational Heart, Lung, and Blood Institute (NHLBI)CompletatoTracheotomia | Insufficienza respiratoria acuta | Ventilazione meccanicaStati Uniti
-
Dr. David MasloveIronstone Professional DevelopmentCompletato
-
Medtronic Spinal and BiologicsCompletato
-
DePuy SpineCompletatoMalattia degenerativa del discoStati Uniti
-
Medical University of South CarolinaNational Institutes of Health (NIH)ReclutamentoMalattia polmonare interstiziale | Fibrosi polmonare progressivaStati Uniti