Prospective, Randomized, Parallel-group Comparison of Two Refractive EDOF Intraocular Lenses: Johnson & Johnson Tecnis PureSee Versus 1stQ Comfort Z-EDOF (1stQvsPureSee)

2026年6月30日 更新者:Prim. Univ.-Prof. Dr. Pia Veronika Vécsei-Marlovits, MSc, MB、Vienna Hospital Association

This study compares two types of artificial lens (intraocular lens, or IOL) used during cataract surgery. Both are extended depth-of-focus (EDOF) lenses, designed to give clear vision across a range of distances - far and intermediate - so that people depend less on glasses after surgery. The two lenses, the Tecnis PureSee and the 1stQ Comfort Z-EDOF, use different optical designs, and it is not yet known whether one provides a wider range of clear vision than the other.

Adults having cataract surgery in both eyes may take part. Each participant is randomly assigned to receive one of the two lens types, and the same lens type is implanted in both eyes. Neither the participant nor the staff measuring vision knows which lens was used until the main 6-month assessment is complete.

After surgery, participants attend check-ups at 1, 3, and 6 months. The study measures how wide a range of distances each person can see clearly, along with vision at different distances, quality of vision, side effects such as glare or halos, and overall satisfaction. The results will help doctors and patients choose between these lens types.

研究概览

详细说明

Background and rationale: Extended depth-of-focus (EDOF) intraocular lenses (IOLs) extend the range of functional vision beyond that of conventional monofocal IOLs by modifying the eye's wavefront to create an elongated focal range, while aiming to limit the photic phenomena (halos, glare, starbursts) often associated with multifocal IOLs. Different EDOF platforms use fundamentally different optical strategies, yet direct comparative evidence between EDOF designs from prospective randomized trials is limited; most published studies compare an EDOF IOL with monofocal or multifocal lenses rather than with another EDOF design. This trial provides a head-to-head comparison of two purely refractive EDOF platforms that employ different optical principles: the Tecnis PureSee (Johnson & Johnson Vision), a refractive EDOF design with a continuous power profile and negative spherical aberration, and the 1stQ Comfort Z-EDOF (1stQ GmbH), a refractive aspheric EDOF design with a modified spherical aberration profile.

Design: This is a single-center, prospective, randomized, parallel-group comparative study conducted at the Department of Ophthalmology, Klinik Hietzing, Vienna, Austria. Patients undergoing bilateral cataract surgery are randomized 1:1 to receive one of the two EDOF IOL platforms, implanted bilaterally (the same platform in both eyes). Randomization uses permuted blocks and is stratified by toric versus non-toric IOL variant; patients with preoperative corneal astigmatism greater than 0.75 D receive the toric version of the assigned platform. Target refraction is emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye. Participants and outcome assessors are masked to lens allocation until the 6-month primary endpoint assessment is complete; the operating surgeon cannot be masked.

The study compares monocular (eye-level) and binocular (patient-level) outcomes between the two platforms. The primary endpoint is the monocular distance-corrected defocus range at the 0.2 logMAR threshold, measured 6 months after surgery from a standardized defocus curve (4-meter ETDRS chart, defocus +1.0 D to -3.5 D in 0.5 D steps). Secondary assessments include visual acuity at multiple distances, the complete defocus curve, manifest refraction and astigmatic vector components, higher-order wavefront aberrations, rotational stability of the toric variants, patient-reported visual function and quality of vision (including halos, glare, and starbursts), spectacle independence, satisfaction, and surgical safety.

Assessments are performed preoperatively and at 1, 3, and 6 months postoperatively. The primary analysis compares the mean monocular defocus range between groups using one eye per patient (the first-operated eye), with sensitivity analyses using both eyes and appropriate adjustment for within-patient correlation. The study is regulated as a post-market clinical follow-up (PMCF) investigation under Article 74(1) of Regulation (EU) 2017/745; both lenses are CE-marked and used within their approved intended purpose.

研究类型

介入性

注册 (估计的)

110

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

    • State of Vienna
      • Vienna、State of Vienna、奥地利、1130
        • Augenabteilung, Klinik Hietzing, Wiener Gesundheitsverbund
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不

描述

Inclusion Criteria:

  • Age ≥40 years, able to understand the study and give written informed consent
  • Clinically significant bilateral age-related cataract suitable for phacoemulsification with posterior chamber IOL implantation
  • Expected postoperative best-corrected visual acuity ≤0.2 logMAR in both eyes
  • Regular corneal astigmatism ≤4.5 D in both eyes (IOLMaster 700)
  • Axial length 21.5-26.5 mm in both eyes
  • Clear cornea without clinically significant opacities, scars, or stromal dystrophies
  • Normal pupil function; no significant anisocoria (≥1 mm) and no afferent pupillary defect
  • Acceptance of the target refraction strategy: emmetropia in the dominant eye and -0.50 D in the non-dominant eye
  • Willing and able to attend all follow-up visits (Month 1, 3, and 6)
  • Written informed consent obtained before any study-related procedure

Exclusion Criteria:

  • Prior corneal refractive surgery, corneal transplantation, glaucoma filtering surgery, or vitreoretinal surgery in either eye (uncomplicated intravitreal injections allowed)
  • Irregular astigmatism, keratoconus, forme fruste keratoconus, corneal ectasia, significant corneal opacities or scars, or endothelial dystrophy
  • Keratometric astigmatism >4.5 D in either eye
  • Axial length <21.5 mm or >26.5 mm in either eye
  • Calculated IOL power outside the available range of either study lens
  • Macular pathology expected to limit visual acuity (e.g., age-related macular degeneration, diabetic maculopathy, epiretinal membrane, macular hole)
  • Advanced glaucoma with central visual field involvement, or IOP not controlled on ≤2 topical medications
  • Optic neuropathy expected to limit visual potential
  • Pre-existing amblyopia in either eye
  • Significant anisocoria, afferent pupillary defect, non-dilating pupil, or iris abnormalities affecting IOL function or measurement
  • Endothelial cell density <1500 cells/mm²
  • Uncontrolled diabetes mellitus (HbA1c >9%) or autoimmune disease with active ocular involvement
  • Systemic medications affecting pupil size that cannot be discontinued (e.g., tamsulosin)
  • Pregnancy or breastfeeding
  • Intraoperative complication precluding safe in-the-bag IOL implantation (affected eyes withdrawn)
  • Cognitive impairment, language barrier, or other factors preventing reliable participation
  • Current enrollment in another interventional clinical study affecting visual outcomes

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:随机化
  • 介入模型:并行分配
  • 屏蔽:双倍的

武器和干预

参与者组/臂
干预/治疗
实验性的:Tecnis PureSee
Bilateral implantation of the Tecnis PureSee refractive extended depth-of-focus IOL (Johnson & Johnson Vision; non-toric model ZEN00V or toric DET series). The same lens platform is implanted in both eyes. Target refraction: emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye.
Phacoemulsification with bilateral implantation of the Tecnis PureSee refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.
有源比较器:1stQ Comfort Z-EDOF
Bilateral implantation of the 1stQ Comfort Z-EDOF refractive extended depth-of-focus IOL (1stQ GmbH; non-toric models B1XBY0/S1XBY0 or toric B1ZBY0). The same lens platform is implanted in both eyes. Target refraction: emmetropia in the dominant eye and approximately -0.50 D in the non-dominant eye.
Phacoemulsification with bilateral implantation of the 1stQ Comfort Z-EDOF refractive EDOF IOL in the capsular bag. Toric variant used for preoperative corneal astigmatism greater than 0.75 D.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Monocular distance-corrected defocus range (DCDR) at 0.2 logMAR
大体时间:6 months after surgery
Maximum contiguous defocus span (in diopters) over which monocular distance-corrected visual acuity remains ≤0.2 logMAR, derived from a standardized defocus curve (4 m ETDRS chart; +1.0 D to -3.5 D in 0.5 D steps).
6 months after surgery

次要结果测量

结果测量
措施说明
大体时间
Monocular visual acuity at multiple distances
大体时间:6 months after surgery
logMAR acuity: UDVA and CDVA (4 m); UIVA at 66 cm and 80 cm and DCIVA (intermediate); UNVA at 40 cm and DCNVA (near).
6 months after surgery

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年8月1日

初级完成 (估计的)

2029年4月1日

研究完成 (估计的)

2029年4月1日

研究注册日期

首次提交

2026年6月30日

首先提交符合 QC 标准的

2026年6月30日

首次发布 (实际的)

2026年7月7日

研究记录更新

最后更新发布 (实际的)

2026年7月7日

上次提交的符合 QC 标准的更新

2026年6月30日

最后验证

2026年6月1日

更多信息

与本研究相关的术语

关键字

其他相关的 MeSH 术语

其他研究编号

  • MA_15_EK_26_094_VK

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅