Comparison of Non-Calibrated Splinting Bodies and T-Marker for Complete-Arch Implant Scanning
Accuracy of Complete-Arch Implant Scans Obtained Using Non-Calibrated Splinting Bodies and a Mobile Phone-Based Photogrammetry System (T-Marker): A Randomized Crossover Clinical Trial
This randomized crossover clinical trial aims to compare the accuracy and scanning efficiency of two digital techniques for recording implant positions in completely edentulous patients receiving implant-supported full-arch prostheses. Each participant will undergo digital impressions using both a non-calibrated splinting scan body system (IoConnect) with an intraoral scanner and a mobile phone-based photogrammetry system (T-Marker). The order of the two scanning methods will be randomized.
The primary outcome is the accuracy (trueness) of implant position recording, assessed by comparing each digital impression with a verified reference model. Secondary outcomes include the time required to complete each digital impression. The findings of this study may help determine whether these digital workflows provide accurate and efficient alternatives for complete-arch implant impressions, thereby supporting clinical decision-making in implant prosthodontics.
研究概览
地位
详细说明
Detailed Description
Accurate recording of implant positions is essential for the fabrication of passively fitting implant-supported full-arch prostheses. Although intraoral scanners have demonstrated acceptable accuracy for single implants and short-span restorations, complete-arch implant scanning remains challenging because of the absence of stable anatomical landmarks, long interimplant distances, and cumulative image stitching errors. To overcome these limitations, several digital impression techniques have been developed, including splinted implant scan body systems and photogrammetry-based workflows.
Recently, non-calibrated splinting scan body systems have been introduced to improve the stability of implant scan bodies during intraoral scanning without requiring scanner-specific calibration. In parallel, mobile phone-based photogrammetry systems have emerged as simplified and more accessible alternatives for capturing implant positions. However, clinical evidence directly comparing these technologies is limited.
This prospective randomized crossover clinical trial will compare the accuracy and scanning efficiency of a non-calibrated splinting scan body workflow (IoConnect) with a mobile phone-based photogrammetry system (T-Marker) for complete-arch implant impressions. Twenty-four completely edentulous patients rehabilitated with four implant-supported multiunit abutments will undergo digital impressions using both techniques. The order of the scanning procedures will be randomized using a computer-generated randomization sequence, allowing each participant to serve as their own control.
A verified conventional splinted impression and master cast will be fabricated for each participant and digitized with a high-accuracy laboratory scanner to generate the reference dataset. Digital impressions obtained with both workflows will be compared with the reference model using three-dimensional metrology software. Trueness will be evaluated by measuring linear and angular deviations of implant positions after standardized replacement of the scan bodies with their corresponding CAD library files and construction of an identical virtual implant-supported bar for all datasets.
The primary objective is to compare the trueness of implant position acquisition between the two digital workflows. The secondary objective is to compare the effective chairside scanning time required for implant position acquisition. The results of this study are expected to provide clinical evidence regarding the accuracy and efficiency of these emerging digital workflows and to support evidence-based selection of digital impression techniques for complete-arch implant rehabilitation.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Mohammed A. Elsawy, PhD
- 电话号码:00201061314522
- 邮箱:mohamed.elsawy@dent.menofia.edu.eg
学习地点
-
-
Shibin Alkom
-
Shibīn al Kawm、Shibin Alkom、埃及、2266166
- 招聘中
- Mohammed Elsawy
-
接触:
- Mohammed Algharissi, PhD
- 邮箱:mohamed.elsawy@dent.menofia.edu.eg
-
-
参与标准
资格标准
适合学习的年龄
- 成人
接受健康志愿者
描述
Inclusion Criteria
- Adults aged 18 years or older.
- Completely edentulous maxilla rehabilitated with four well-integrated implants connected to multiunit abutments.
- Patients presenting with a screw-retained interim implant-supported prosthesis or requiring a definitive implant-supported prosthesis.
- Adequate implant osseointegration with no clinical signs of implant failure.
- Ability to understand the study procedures and provide written informed consent.
Exclusion Criteria
- Fewer than four implants supporting the maxillary prosthesis.
- Implants located outside the maxillary arch.
- Failed implants or implants exhibiting mobility.
- Active peri-implant infection or suppuration.
- Inability to tolerate intraoral scanning or comply with study procedures.
- Refusal or inability to provide written informed consent.
学习计划
研究是如何设计的?
设计细节
- 主要用途:诊断
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Experimental: IoConnect → T-Marker
Participants first undergo complete-arch digital implant impressions using the non-calibrated splinting workflow (IoConnect), followed by the mobile phone-based photogrammetry workflow (T-Marker).
|
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions.
The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
其他名称:
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments.
The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
其他名称:
|
|
实验性的:Experimental: T-Marker → IoConnect
Participants first undergo complete-arch digital implant impressions using the mobile phone-based photogrammetry workflow (T-Marker), followed by the non-calibrated splinting workflow (IoConnect).
|
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions.
The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
其他名称:
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments.
The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
其他名称:
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Trueness of Complete-Arch Implant Position Recording
大体时间:Immediately after completion of each digital impression (during the 1 day study visit).
|
Trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset generated from a conventional splinted impression.
Three-dimensional analysis will be performed using reverse-engineering software to calculate the linear (µm) and angular (degrees) deviations of implant positions.
Lower deviation values indicate greater trueness.
|
Immediately after completion of each digital impression (during the 1 day study visit).
|
|
Angular Deviation of Complete-Arch Implant Position Recording
大体时间:Immediately after completion of each digital impression (during the 1 day study visit).
|
Angular trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset.
Three-dimensional analysis will be performed using reverse-engineering software to calculate the angular deviation (degrees) of implant axes.
Lower values indicate greater trueness.
|
Immediately after completion of each digital impression (during the 1 day study visit).
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Effective Chairside Scanning Time
大体时间:Immediately after completion of each digital impression (during the 1 day study visit).
|
Time required to capture and register implant positions using each digital impression workflow, measured in seconds.
Only the implant position acquisition phase will be included; soft-tissue scanning, STL export, and data processing will be excluded.
|
Immediately after completion of each digital impression (during the 1 day study visit).
|
合作者和调查者
调查人员
- 首席研究员:Mohammed Elsawy, PhD、Menoufia University
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- ADMNF-0226
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.