Comparison of Non-Calibrated Splinting Bodies and T-Marker for Complete-Arch Implant Scanning

8 сентября 2026 г. обновлено: Mohammed El-Sawy, Menoufia University

Accuracy of Complete-Arch Implant Scans Obtained Using Non-Calibrated Splinting Bodies and a Mobile Phone-Based Photogrammetry System (T-Marker): A Randomized Crossover Clinical Trial

This randomized crossover clinical trial aims to compare the accuracy and scanning efficiency of two digital techniques for recording implant positions in completely edentulous patients receiving implant-supported full-arch prostheses. Each participant will undergo digital impressions using both a non-calibrated splinting scan body system (IoConnect) with an intraoral scanner and a mobile phone-based photogrammetry system (T-Marker). The order of the two scanning methods will be randomized.

The primary outcome is the accuracy (trueness) of implant position recording, assessed by comparing each digital impression with a verified reference model. Secondary outcomes include the time required to complete each digital impression. The findings of this study may help determine whether these digital workflows provide accurate and efficient alternatives for complete-arch implant impressions, thereby supporting clinical decision-making in implant prosthodontics.

Обзор исследования

Подробное описание

Detailed Description

Accurate recording of implant positions is essential for the fabrication of passively fitting implant-supported full-arch prostheses. Although intraoral scanners have demonstrated acceptable accuracy for single implants and short-span restorations, complete-arch implant scanning remains challenging because of the absence of stable anatomical landmarks, long interimplant distances, and cumulative image stitching errors. To overcome these limitations, several digital impression techniques have been developed, including splinted implant scan body systems and photogrammetry-based workflows.

Recently, non-calibrated splinting scan body systems have been introduced to improve the stability of implant scan bodies during intraoral scanning without requiring scanner-specific calibration. In parallel, mobile phone-based photogrammetry systems have emerged as simplified and more accessible alternatives for capturing implant positions. However, clinical evidence directly comparing these technologies is limited.

This prospective randomized crossover clinical trial will compare the accuracy and scanning efficiency of a non-calibrated splinting scan body workflow (IoConnect) with a mobile phone-based photogrammetry system (T-Marker) for complete-arch implant impressions. Twenty-four completely edentulous patients rehabilitated with four implant-supported multiunit abutments will undergo digital impressions using both techniques. The order of the scanning procedures will be randomized using a computer-generated randomization sequence, allowing each participant to serve as their own control.

A verified conventional splinted impression and master cast will be fabricated for each participant and digitized with a high-accuracy laboratory scanner to generate the reference dataset. Digital impressions obtained with both workflows will be compared with the reference model using three-dimensional metrology software. Trueness will be evaluated by measuring linear and angular deviations of implant positions after standardized replacement of the scan bodies with their corresponding CAD library files and construction of an identical virtual implant-supported bar for all datasets.

The primary objective is to compare the trueness of implant position acquisition between the two digital workflows. The secondary objective is to compare the effective chairside scanning time required for implant position acquisition. The results of this study are expected to provide clinical evidence regarding the accuracy and efficiency of these emerging digital workflows and to support evidence-based selection of digital impression techniques for complete-arch implant rehabilitation.

Тип исследования

Интервенционный

Регистрация (Оцененный)

40

Фаза

  • Непригодный

Контакты и местонахождение

В этом разделе приведены контактные данные лиц, проводящих исследование, и информация о том, где проводится это исследование.

Контакты исследования

Места учебы

Критерии участия

Исследователи ищут людей, которые соответствуют определенному описанию, называемому критериям приемлемости. Некоторыми примерами этих критериев являются общее состояние здоровья человека или предшествующее лечение.

Критерии приемлемости

Возраст, подходящий для обучения

  • Взрослый

Принимает здоровых добровольцев

Нет

Описание

Inclusion Criteria

  • Adults aged 18 years or older.
  • Completely edentulous maxilla rehabilitated with four well-integrated implants connected to multiunit abutments.
  • Patients presenting with a screw-retained interim implant-supported prosthesis or requiring a definitive implant-supported prosthesis.
  • Adequate implant osseointegration with no clinical signs of implant failure.
  • Ability to understand the study procedures and provide written informed consent.

Exclusion Criteria

  • Fewer than four implants supporting the maxillary prosthesis.
  • Implants located outside the maxillary arch.
  • Failed implants or implants exhibiting mobility.
  • Active peri-implant infection or suppuration.
  • Inability to tolerate intraoral scanning or comply with study procedures.
  • Refusal or inability to provide written informed consent.

Учебный план

В этом разделе представлена ​​подробная информация о плане исследования, в том числе о том, как планируется исследование и что оно измеряет.

Как устроено исследование?

Детали дизайна

  • Основная цель: Диагностика
  • Распределение: Рандомизированный
  • Интервенционная модель: Назначение кроссовера
  • Маскировка: Нет (открытая этикетка)

Оружие и интервенции

Группа участников / Армия
Вмешательство/лечение
Экспериментальный: Experimental: IoConnect → T-Marker
Participants first undergo complete-arch digital implant impressions using the non-calibrated splinting workflow (IoConnect), followed by the mobile phone-based photogrammetry workflow (T-Marker).
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions. The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
Другие имена:
  • IoConnect Flags; True Abutment; Medit i700
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments. The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
Другие имена:
  • T-Marker; TruAbutment T-Marker; iPhone 15 Pro Max
Экспериментальный: Experimental: T-Marker → IoConnect
Participants first undergo complete-arch digital implant impressions using the mobile phone-based photogrammetry workflow (T-Marker), followed by the non-calibrated splinting workflow (IoConnect).
A non-calibrated splinting scan body system used with an intraoral scanner to record complete-arch implant positions. The workflow uses splinted scan bodies that are digitally merged with the soft-tissue scan to generate the definitive implant impression.
Другие имена:
  • IoConnect Flags; True Abutment; Medit i700
A smartphone-based photogrammetry system used to capture complete-arch implant positions through optical markers attached to multiunit abutments. The system generates a digital implant position dataset for prosthetic workflow and accuracy assessment.
Другие имена:
  • T-Marker; TruAbutment T-Marker; iPhone 15 Pro Max

Что измеряет исследование?

Первичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Trueness of Complete-Arch Implant Position Recording
Временное ограничение: Immediately after completion of each digital impression (during the 1 day study visit).
Trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset generated from a conventional splinted impression. Three-dimensional analysis will be performed using reverse-engineering software to calculate the linear (µm) and angular (degrees) deviations of implant positions. Lower deviation values indicate greater trueness.
Immediately after completion of each digital impression (during the 1 day study visit).
Angular Deviation of Complete-Arch Implant Position Recording
Временное ограничение: Immediately after completion of each digital impression (during the 1 day study visit).
Angular trueness will be assessed by comparing each experimental digital implant impression with a verified reference dataset. Three-dimensional analysis will be performed using reverse-engineering software to calculate the angular deviation (degrees) of implant axes. Lower values indicate greater trueness.
Immediately after completion of each digital impression (during the 1 day study visit).

Вторичные показатели результатов

Мера результата
Мера Описание
Временное ограничение
Effective Chairside Scanning Time
Временное ограничение: Immediately after completion of each digital impression (during the 1 day study visit).
Time required to capture and register implant positions using each digital impression workflow, measured in seconds. Only the implant position acquisition phase will be included; soft-tissue scanning, STL export, and data processing will be excluded.
Immediately after completion of each digital impression (during the 1 day study visit).

Соавторы и исследователи

Здесь вы найдете людей и организации, участвующие в этом исследовании.

Спонсор

Следователи

  • Главный следователь: Mohammed Elsawy, PhD, Menoufia University

Даты записи исследования

Эти даты отслеживают ход отправки отчетов об исследованиях и сводных результатов на сайт ClinicalTrials.gov. Записи исследований и сообщаемые результаты проверяются Национальной медицинской библиотекой (NLM), чтобы убедиться, что они соответствуют определенным стандартам контроля качества, прежде чем публиковать их на общедоступном веб-сайте.

Изучение основных дат

Начало исследования (Действительный)

1 апреля 2026 г.

Первичное завершение (Оцененный)

1 декабря 2026 г.

Завершение исследования (Оцененный)

1 января 2027 г.

Даты регистрации исследования

Первый отправленный

18 июля 2026 г.

Впервые представлено, что соответствует критериям контроля качества

22 июля 2026 г.

Первый опубликованный (Действительный)

23 июля 2026 г.

Обновления учебных записей

Последнее опубликованное обновление (Действительный)

9 сентября 2026 г.

Последнее отправленное обновление, отвечающее критериям контроля качества

8 сентября 2026 г.

Последняя проверка

1 сентября 2026 г.

Дополнительная информация

Термины, связанные с этим исследованием

Другие идентификационные номера исследования

  • ADMNF-0226

Информация о лекарствах и устройствах, исследовательские документы

Изучает лекарственный продукт, регулируемый FDA США.

Нет

Изучает продукт устройства, регулируемый Управлением по санитарному надзору за качеством пищевых продуктов и медикаментов США.

Нет

Эта информация была получена непосредственно с веб-сайта clinicaltrials.gov без каких-либо изменений. Если у вас есть запросы на изменение, удаление или обновление сведений об исследовании, обращайтесь по адресу register@clinicaltrials.gov. Как только изменение будет реализовано на clinicaltrials.gov, оно будет автоматически обновлено и на нашем веб-сайте. .

Подписаться