此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Validating AI for Gender Prediction Using Morphometric Analysis of the Mandible

2026年7月22日 更新者:Ashrakat Abdelmonem Mohamed Mohamed Habib、Cairo University

The Accuracy of Artificial Intelligence in Gender Prediction Using Morphometric Analysis of the Mandible - a Validity Study

This retrospective validity study evaluates the accuracy of artificial intelligence (AI) in determining gender from mandibular morphometric linear measurements. The study utilizes pre-existing Cone Beam Computed Tomography (CBCT) scans of adult Egyptian dental patients. After automatic segmentation of the mandible from these scans, a radiologist will manually perform measurements from certain anatomical points. These measurements will be the reference standard for the AI models.

A three-dimensional deep learning model will be developed to perform two tasks:

  1. To identify the anatomical points and make the specified linear measurements from these points on the segmented mandibles
  2. To accurately predict gender based on these measurements. (Main Objective) The primary objective of this study is to evaluate the accuracy of machine learning algorithms in gender identification from linear morphometric measurements of the mandible. The known gender from patient records will serve as the reference standard.

This study will assess the reliability of AI as an objective tool for gender determination for forensic purposes.

研究概览

详细说明

Study Overview and Objective:

  1. To evaluate the accuracy of machine learning algorithms (ANN and logistic regression) in gender identification from linear morphometric measurements of the mandible. These measurements will be derived from automated mandibular segmentations from CBCT scans of a sample of Egyptian dental patients. The AI model's accuracy, precision, and sensitivity (recall) will be assessed. The model's predictions will be compared to the known gender from patient records.
  2. To evaluate the accuracy of AI (3D UNet) in anatomical point identification and linear measurement. The model's performance will be compared to the radiologist's manual point placement and measurements.

Rationale:

Gender identification is vital in forensic odontology as it makes individual identification easier and faster. Artificial Intelligence can improve accuracy, speed, and efficiency in gender identification processes. The mandible is a sturdy bone with dimorphic features that can aid in gender determination even if other bones are lost. Cone beam computed tomography (CBCT) provides accurate 3D images and therefore accurate measurements. Linear morphometric measurements of the mandible derived from CBCT will provide an objective way of gender determination. AI algorithms can use these measurements to predict gender. Evaluating the accuracy of artificial intelligence in gender determination using morphometric measurements from CBCT-based mandibular segmentations is therefore essential to assess its reliability and potential value as an objective diagnostic tool in forensic practice.

Data Source and Population: Pre-existing, anonymized CBCT scans will be retrieved from the archives of the Oral and Maxillofacial Radiology clinic at the Faculty of Dentistry, Cairo University.

Sample Size Calculation The sample size was calculated to be 385 CBCT DICOMs using the Stats Kingdom statistical tool, based on the primary outcome - accuracy of AI in gender prediction. The power of study was 0.8, the margin of error was 0.04 and the alpha level of significance was 0.05.

Methodology:

Reference standard:

After recruiting a scan in the study, the name of the patient will be removed, and the scan will be given an identification number instead. One of the supervisors will have a dataset with the identification number, age, and the correct gender written before all personal information is erased from the CBCT scan. This will ensure that the radiologist performing the morphometric measurements will be blinded.

The DICOM file will be opened in 3D slicer imaging software (version 5.10.0; MIT, Cambridge, MA, USA) where automatic segmentation of the mandible will be peformed.

The radiologist performing the measurements has 2 years of experience. The following linear measurements will be performed: bi-coronoid width, bi-condylar width, distance from right gonion to menton and left gonion to menton, and distance from right coronoid to right gonion and left coronoid to left gonion.These measurements will be written in a separate dataset with the identification number of the scan with no information about the gender. Interobserver agreement will be validated by a senior radiologist (>15 years experience) who will re-evaluate a 30% sample of the cases. The datasets will be sent to a statistician to assess the normality of data and sexual dimorphism.

The segmented mandibles (NRRD files) and the measurement files (JSON files) will be saved for each case to be introduced in the AI model by the AI engineer.

Index test:

A three-dimensional deep learning model will be developed to perform two tasks:

  1. To identify the anatomical points and make the specified linear measurements from these points on the segmented mandibles
  2. To accurately predict gender based on these measurements The AI engineer will be responsible for model implementation. For the first task, 3D U-Net model will be employed. The NRRD and JSON files will be introduced to the model for training and testing. For the second task, Artificial neural networks and logistic regression will be used.

Data preprocessing will be performed and the dataset will be divided into training, validation, and testing subsets to ensure balanced and unbiased evaluation. K-fold cross-validation will be used if sample size is small.

Training:

The landmark detection model will be trained using supervised learning techniques .The classification models will subsequently be trained using the extracted feature representations. Each model will be trained using the same training data and preprocessing pipeline.

Testing:

In the testing phase, the trained system will process unseen segmented mandibles to automatically localize keypoints, compute relevant geometric features, and generate gender predictions without further model updates.

Evaluation and Expected Outcome:

Model performance will be evaluated using quantitative localization error metrics for keypoint detection and standard classification metrics for gender prediction.

Statistical Analysis:

Statistical tests will be applied to assess the normality of data and sexual dimorphism of the linear morphometric mandibular measurements before introducing these measurements to the AI model. Mean Euclidean Distance Error (in millimeters), and Root Mean Square Error (RMSE) will be used to assess the accuracy of the model in anatomical point placement in comparison to the radiologist's measurements. Accuracy, Precision, Recall (sensitivity), Specificity, F1-score, and a Confusion matrix will be used to evaluate the prediction models.

No data will be missed considering the retrospective nature of the study

研究类型

观察性的

注册 (估计的)

385

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

      • Cairo、埃及
        • 招聘中
        • Faculty of Dentistry, Cairo University
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人
  • 年长者

接受健康志愿者

不适用

取样方法

非概率样本

研究人群

CBCT scans of patients, who have already been imaged for other treatment purposes, will be retrieved.

Automatically segmented mandibles from these CBCT scans will be the population of the study.

描述

Inclusion Criteria:

  • Scans belonging to patients above or at the age of 18 years (≥ 18 years)
  • Scans that image the area of interest clearly (mandible) with a craniofacial or maxillomandibular field of view.
  • Good quality of the scan with no artefacts

Exclusion Criteria:

  • CBCT scans with significant artifacts (e.g. metal artefact) affecting visualization of the mandible
  • Congenital craniofacial anomalies affecting the mandibular anatomy
  • Large pathologies that affect the mandible's dimensions and cause significant bone loss.
  • Trauma to the mandible

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
Pre-existing CBCT scans from adult Egyptian dental patients showing the mandible.
All scans within this cohort undergo the same automatic segmentation followed by expert landmark placement and measurement taking. Subsequently, these segmentations will be introduced to the AI model for automated landmark placement, measurements and finally gender prediction based on these measurements.

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Accuracy of AI in gender prediction
大体时间:At study completion (at completion of analysis of the validation dataset) (12 months)

The accuracy of machine learning models (Artificial Neural Networks and Logistic Regression) in gender prediction. The predictions results are compared to the known gender from patient records which serve as the reference standard. The measuring unit is categorical as male or female.

Accuracy, Precision, Recall (sensitivity), Specificity, F1-score, and a Confusion matrix will be used to evaluate the prediction models.

At study completion (at completion of analysis of the validation dataset) (12 months)

次要结果测量

结果测量
措施说明
大体时间
Accuracy of AI in anatomical point placement and linear measurements
大体时间:At study completion (at completion of analysis of the validation dataset) (12 months)

Landmark placement and linear measurments of 3D UNet model versus radiologists' manual measurements will be compared. The measuring unit will be in millimeters (mm).

Mean Euclidean Distance Error (in millimeters), and Root Mean Square Error (RMSE) will be used to assess the accuracy of the model in anatomical point placement in comparison to the radiologist's measurements

At study completion (at completion of analysis of the validation dataset) (12 months)

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 研究主任:Ola Mohamed Associate professor、Oral and Maxillofacial Radiology, Faculty of Dentistry, Cairo University

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年6月1日

初级完成 (估计的)

2027年3月30日

研究完成 (估计的)

2027年5月1日

研究注册日期

首次提交

2026年7月19日

首先提交符合 QC 标准的

2026年7月22日

首次发布 (实际的)

2026年7月24日

研究记录更新

最后更新发布 (实际的)

2026年7月24日

上次提交的符合 QC 标准的更新

2026年7月22日

最后验证

2026年5月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data will not be made publicly available to protect patient privacy and adhere to institutional ethical guidelines.

All personal information will be removed, and the CBCT scans will be identified by an identification number. Publication of results will not reveal patient identity or allow identification of individuals.

De-identified morphometric mandibular measurements and corresponding gender classifications may be made available upon reasonable request.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅