Validating AI for Gender Prediction Using Morphometric Analysis of the Mandible

22 juli 2026 bijgewerkt door: Ashrakat Abdelmonem Mohamed Mohamed Habib, Cairo University

The Accuracy of Artificial Intelligence in Gender Prediction Using Morphometric Analysis of the Mandible - a Validity Study

This retrospective validity study evaluates the accuracy of artificial intelligence (AI) in determining gender from mandibular morphometric linear measurements. The study utilizes pre-existing Cone Beam Computed Tomography (CBCT) scans of adult Egyptian dental patients. After automatic segmentation of the mandible from these scans, a radiologist will manually perform measurements from certain anatomical points. These measurements will be the reference standard for the AI models.

A three-dimensional deep learning model will be developed to perform two tasks:

  1. To identify the anatomical points and make the specified linear measurements from these points on the segmented mandibles
  2. To accurately predict gender based on these measurements. (Main Objective) The primary objective of this study is to evaluate the accuracy of machine learning algorithms in gender identification from linear morphometric measurements of the mandible. The known gender from patient records will serve as the reference standard.

This study will assess the reliability of AI as an objective tool for gender determination for forensic purposes.

Studie Overzicht

Gedetailleerde beschrijving

Study Overview and Objective:

  1. To evaluate the accuracy of machine learning algorithms (ANN and logistic regression) in gender identification from linear morphometric measurements of the mandible. These measurements will be derived from automated mandibular segmentations from CBCT scans of a sample of Egyptian dental patients. The AI model's accuracy, precision, and sensitivity (recall) will be assessed. The model's predictions will be compared to the known gender from patient records.
  2. To evaluate the accuracy of AI (3D UNet) in anatomical point identification and linear measurement. The model's performance will be compared to the radiologist's manual point placement and measurements.

Rationale:

Gender identification is vital in forensic odontology as it makes individual identification easier and faster. Artificial Intelligence can improve accuracy, speed, and efficiency in gender identification processes. The mandible is a sturdy bone with dimorphic features that can aid in gender determination even if other bones are lost. Cone beam computed tomography (CBCT) provides accurate 3D images and therefore accurate measurements. Linear morphometric measurements of the mandible derived from CBCT will provide an objective way of gender determination. AI algorithms can use these measurements to predict gender. Evaluating the accuracy of artificial intelligence in gender determination using morphometric measurements from CBCT-based mandibular segmentations is therefore essential to assess its reliability and potential value as an objective diagnostic tool in forensic practice.

Data Source and Population: Pre-existing, anonymized CBCT scans will be retrieved from the archives of the Oral and Maxillofacial Radiology clinic at the Faculty of Dentistry, Cairo University.

Sample Size Calculation The sample size was calculated to be 385 CBCT DICOMs using the Stats Kingdom statistical tool, based on the primary outcome - accuracy of AI in gender prediction. The power of study was 0.8, the margin of error was 0.04 and the alpha level of significance was 0.05.

Methodology:

Reference standard:

After recruiting a scan in the study, the name of the patient will be removed, and the scan will be given an identification number instead. One of the supervisors will have a dataset with the identification number, age, and the correct gender written before all personal information is erased from the CBCT scan. This will ensure that the radiologist performing the morphometric measurements will be blinded.

The DICOM file will be opened in 3D slicer imaging software (version 5.10.0; MIT, Cambridge, MA, USA) where automatic segmentation of the mandible will be peformed.

The radiologist performing the measurements has 2 years of experience. The following linear measurements will be performed: bi-coronoid width, bi-condylar width, distance from right gonion to menton and left gonion to menton, and distance from right coronoid to right gonion and left coronoid to left gonion.These measurements will be written in a separate dataset with the identification number of the scan with no information about the gender. Interobserver agreement will be validated by a senior radiologist (>15 years experience) who will re-evaluate a 30% sample of the cases. The datasets will be sent to a statistician to assess the normality of data and sexual dimorphism.

The segmented mandibles (NRRD files) and the measurement files (JSON files) will be saved for each case to be introduced in the AI model by the AI engineer.

Index test:

A three-dimensional deep learning model will be developed to perform two tasks:

  1. To identify the anatomical points and make the specified linear measurements from these points on the segmented mandibles
  2. To accurately predict gender based on these measurements The AI engineer will be responsible for model implementation. For the first task, 3D U-Net model will be employed. The NRRD and JSON files will be introduced to the model for training and testing. For the second task, Artificial neural networks and logistic regression will be used.

Data preprocessing will be performed and the dataset will be divided into training, validation, and testing subsets to ensure balanced and unbiased evaluation. K-fold cross-validation will be used if sample size is small.

Training:

The landmark detection model will be trained using supervised learning techniques .The classification models will subsequently be trained using the extracted feature representations. Each model will be trained using the same training data and preprocessing pipeline.

Testing:

In the testing phase, the trained system will process unseen segmented mandibles to automatically localize keypoints, compute relevant geometric features, and generate gender predictions without further model updates.

Evaluation and Expected Outcome:

Model performance will be evaluated using quantitative localization error metrics for keypoint detection and standard classification metrics for gender prediction.

Statistical Analysis:

Statistical tests will be applied to assess the normality of data and sexual dimorphism of the linear morphometric mandibular measurements before introducing these measurements to the AI model. Mean Euclidean Distance Error (in millimeters), and Root Mean Square Error (RMSE) will be used to assess the accuracy of the model in anatomical point placement in comparison to the radiologist's measurements. Accuracy, Precision, Recall (sensitivity), Specificity, F1-score, and a Confusion matrix will be used to evaluate the prediction models.

No data will be missed considering the retrospective nature of the study

Studietype

Observationeel

Inschrijving (Geschat)

385

Contacten en locaties

In dit gedeelte vindt u de contactgegevens van degenen die het onderzoek uitvoeren en informatie over waar dit onderzoek wordt uitgevoerd.

Studiecontact

Studie Locaties

Deelname Criteria

Onderzoekers zoeken naar mensen die aan een bepaalde beschrijving voldoen, de zogenaamde geschiktheidscriteria. Enkele voorbeelden van deze criteria zijn iemands algemene gezondheidstoestand of eerdere behandelingen.

Geschiktheidscriteria

Leeftijden die in aanmerking komen voor studie

  • Volwassen
  • Oudere volwassene

Accepteert gezonde vrijwilligers

NVT

Bemonsteringsmethode

Niet-waarschijnlijkheidssteekproef

Studie Bevolking

CBCT scans of patients, who have already been imaged for other treatment purposes, will be retrieved.

Automatically segmented mandibles from these CBCT scans will be the population of the study.

Beschrijving

Inclusion Criteria:

  • Scans belonging to patients above or at the age of 18 years (≥ 18 years)
  • Scans that image the area of interest clearly (mandible) with a craniofacial or maxillomandibular field of view.
  • Good quality of the scan with no artefacts

Exclusion Criteria:

  • CBCT scans with significant artifacts (e.g. metal artefact) affecting visualization of the mandible
  • Congenital craniofacial anomalies affecting the mandibular anatomy
  • Large pathologies that affect the mandible's dimensions and cause significant bone loss.
  • Trauma to the mandible

Studie plan

Dit gedeelte bevat details van het studieplan, inclusief hoe de studie is opgezet en wat de studie meet.

Hoe is de studie opgezet?

Ontwerpdetails

Cohorten en interventies

Groep / Cohort
Pre-existing CBCT scans from adult Egyptian dental patients showing the mandible.
All scans within this cohort undergo the same automatic segmentation followed by expert landmark placement and measurement taking. Subsequently, these segmentations will be introduced to the AI model for automated landmark placement, measurements and finally gender prediction based on these measurements.

Wat meet het onderzoek?

Primaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Accuracy of AI in gender prediction
Tijdsspanne: At study completion (at completion of analysis of the validation dataset) (12 months)

The accuracy of machine learning models (Artificial Neural Networks and Logistic Regression) in gender prediction. The predictions results are compared to the known gender from patient records which serve as the reference standard. The measuring unit is categorical as male or female.

Accuracy, Precision, Recall (sensitivity), Specificity, F1-score, and a Confusion matrix will be used to evaluate the prediction models.

At study completion (at completion of analysis of the validation dataset) (12 months)

Secundaire uitkomstmaten

Uitkomstmaat
Maatregel Beschrijving
Tijdsspanne
Accuracy of AI in anatomical point placement and linear measurements
Tijdsspanne: At study completion (at completion of analysis of the validation dataset) (12 months)

Landmark placement and linear measurments of 3D UNet model versus radiologists' manual measurements will be compared. The measuring unit will be in millimeters (mm).

Mean Euclidean Distance Error (in millimeters), and Root Mean Square Error (RMSE) will be used to assess the accuracy of the model in anatomical point placement in comparison to the radiologist's measurements

At study completion (at completion of analysis of the validation dataset) (12 months)

Medewerkers en onderzoekers

Hier vindt u mensen en organisaties die betrokken zijn bij dit onderzoek.

Onderzoekers

  • Studie directeur: Ola Mohamed Associate professor, Oral and Maxillofacial Radiology, Faculty of Dentistry, Cairo University

Studie record data

Deze datums volgen de voortgang van het onderzoeksdossier en de samenvatting van de ingediende resultaten bij ClinicalTrials.gov. Studieverslagen en gerapporteerde resultaten worden beoordeeld door de National Library of Medicine (NLM) om er zeker van te zijn dat ze voldoen aan specifieke kwaliteitscontrolenormen voordat ze op de openbare website worden geplaatst.

Bestudeer belangrijke data

Studie start (Werkelijk)

1 juni 2026

Primaire voltooiing (Geschat)

30 maart 2027

Studie voltooiing (Geschat)

1 mei 2027

Studieregistratiedata

Eerst ingediend

19 juli 2026

Eerst ingediend dat voldeed aan de QC-criteria

22 juli 2026

Eerst geplaatst (Werkelijk)

24 juli 2026

Updates van studierecords

Laatste update geplaatst (Werkelijk)

24 juli 2026

Laatste update ingediend die voldeed aan QC-criteria

22 juli 2026

Laatst geverifieerd

1 mei 2026

Meer informatie

Termen gerelateerd aan deze studie

Plan Individuele Deelnemersgegevens (IPD)

Bent u van plan om gegevens van individuele deelnemers (IPD) te delen?

NEE

Beschrijving IPD-plan

Individual participant data will not be made publicly available to protect patient privacy and adhere to institutional ethical guidelines.

All personal information will be removed, and the CBCT scans will be identified by an identification number. Publication of results will not reveal patient identity or allow identification of individuals.

De-identified morphometric mandibular measurements and corresponding gender classifications may be made available upon reasonable request.

Informatie over medicijnen en apparaten, studiedocumenten

Bestudeert een door de Amerikaanse FDA gereguleerd geneesmiddel

Nee

Bestudeert een door de Amerikaanse FDA gereguleerd apparaatproduct

Nee

Deze informatie is zonder wijzigingen rechtstreeks van de website clinicaltrials.gov gehaald. Als u verzoeken heeft om uw onderzoeksgegevens te wijzigen, te verwijderen of bij te werken, neem dan contact op met register@clinicaltrials.gov. Zodra er een wijziging wordt doorgevoerd op clinicaltrials.gov, wordt deze ook automatisch bijgewerkt op onze website .