Distal Versus Conventional Radial Arterial Catheterization for Arterial Waveform Stability (DRA-stability)
Distal Versus Conventional Radial Arterial Catheterization for Arterial Waveform Stability During Arm-Tucked Robotic Urologic Surgery: A Prospective Randomized Controlled Study
During robot-assisted urologic surgery, both arms are often placed alongside the body and covered by surgical drapes. This position can make the arterial catheter difficult to access during surgery. A conventional radial arterial catheter placed at the wrist may become compressed or bent because of wrist position or arm fixation, which can cause an inaccurate or dampened arterial blood pressure waveform. A distal radial arterial catheter may be less affected by wrist movement or pressure on the forearm.
This single-center randomized study will include 70 adults undergoing robot-assisted urologic surgery under general anesthesia who require invasive arterial blood pressure monitoring. Participants will be randomly assigned in a 1:1 ratio to ultrasound-guided conventional radial arterial catheterization at the wrist or distal radial arterial catheterization near the anatomical snuffbox or back of the hand.
The main purpose of the study is to determine whether distal radial arterial catheterization reduces clinically significant arterial catheter dysfunction requiring troubleshooting or rescue treatment while the arms are tucked. The study will also compare catheter insertion success, first-attempt success, insertion time, episodes of dampened or lost arterial pressure waveforms, difficulty obtaining arterial blood samples, need for catheter replacement or another arterial access site, and catheter-related complications.
研究概览
地位
条件
详细说明
Invasive arterial blood pressure monitoring allows continuous assessment of blood pressure and repeated arterial blood sampling during general anesthesia. The conventional radial artery at the wrist is commonly used for arterial catheterization. However, wrist flexion or extension, arm fixation, surgical drapes, and external pressure may compress or bend the catheter and result in damping or loss of the arterial pressure waveform.
During robot-assisted urologic surgery, both arms are commonly tucked alongside the body. After surgical positioning and robot docking, direct access to the arterial catheter may be limited. A distal radial arterial catheter placed near the anatomical snuffbox or on the dorsal aspect of the hand is located distal to the wrist joint and may therefore be less affected by wrist position and forearm compression.
This is a single-center, prospective, randomized, open-label, superiority study. Seventy adult participants undergoing robot-assisted urologic surgery under general anesthesia and requiring invasive arterial pressure monitoring will be randomly assigned in a 1:1 ratio to conventional radial arterial catheterization or distal radial arterial catheterization. Randomization will be performed using a computer-generated block randomization sequence after written informed consent and confirmation of eligibility.
Both procedures will be performed under ultrasound guidance using standard sterile technique and a standard 20-gauge or 22-gauge over-the-needle arterial catheter. In the conventional radial artery group, the catheter will be inserted at the wrist, approximately 1 to 2 cm proximal to the radial styloid. In the distal radial artery group, the catheter will be inserted into a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal hand. Up to three skin puncture attempts will be permitted. If catheter insertion is unsuccessful or further attempts are considered inappropriate, rescue arterial catheterization will be performed according to standard clinical practice.
Routine prophylactic wrist-extension splints will not be applied in either group. Additional fixation, repositioning, catheter replacement, or other corrective measures may be performed at any time if required for reliable blood pressure monitoring or participant safety. The observation period will begin after both arms have been tucked and will continue until robot undocking or release of the arm-tucked position.
The primary objective is to compare the occurrence of clinically significant arterial catheter dysfunction requiring troubleshooting or rescue intervention during the observation period. Such dysfunction may include persistent damping or loss of the arterial waveform, clinically relevant disagreement between invasive and noninvasive blood pressure measurements, inability to aspirate blood, suspected catheter kinking or compression, or the need for interventions such as flushing, line assessment, dressing adjustment, hand or wrist repositioning, arm untucking, splint application, catheter replacement, or alternative arterial access.
Secondary assessments will include overall and first-attempt insertion success, insertion time, number and duration of waveform damping or loss episodes, difficulty with arterial blood aspiration, need for rescue catheterization, and the procedural burden of maintaining reliable arterial pressure monitoring. Safety assessments will include bleeding, hematoma, vasospasm, infection, pain or sensory symptoms, signs of hand ischemia, suspected radial artery occlusion, catheter replacement, and other unexpected adverse events. Clinically necessary treatment will not be delayed or restricted by study procedures.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Tae Kyong Kim
- 电话号码:82-2-870-2519
- 邮箱:tk99@snu.ac.kr
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Adults aged 19 years or older
- Scheduled to undergo robot-assisted urologic surgery under general anesthesia
- Scheduled to have both arms positioned alongside the body in an arm-tucked position during surgery
- Considered by the attending anesthesiologist to require intraoperative invasive arterial blood pressure monitoring
- Able and willing to provide written informed consent
Exclusion Criteria:
- Refusal to participate or inability to provide written informed consent
- Emergency surgery
- Pregnancy or breastfeeding
- Lack of decision-making capacity requiring consent from a legally authorized representative
- Presence of an arteriovenous fistula for dialysis or unsuitable bilateral radial artery access
- Infection, burn, trauma, surgical scar, or severe skin lesion at the intended puncture site
- Suspected hand perfusion impairment, including radial artery occlusion, absent radial pulse, severe peripheral vascular disease, or Raynaud phenomenon
- Severe coagulopathy or uncorrected bleeding tendency for which radial arterial catheterization is considered inappropriate
- Any condition for which the attending anesthesiologist considers study participation inappropriate for participant safety
学习计划
研究是如何设计的?
设计细节
- 主要用途:其他
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:双倍的
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
有源比较器:Conventional Radial Artery Group
Participants assigned to this arm will undergo ultrasound-guided conventional radial arterial catheterization at the wrist, approximately 1 to 2 cm proximal to the radial styloid.
|
Ultrasound-guided arterial catheterization will be performed at the conventional radial artery at the wrist, approximately 1 to 2 cm proximal to the radial styloid, using standard sterile technique.
A standard sterile disposable 20-gauge or 22-gauge over-the-needle arterial catheter will be selected according to vessel diameter, depth, and clinical judgment.
Up to three skin puncture attempts will be permitted.
After insertion, the catheter will be connected to the pressure monitoring system, zeroed at the level of the right atrium, assessed using a fast-flush test, and secured with a transparent dressing and tape.
Routine prophylactic wrist-extension splinting will not be applied.
Rescue catheterization may be performed according to standard clinical practice if insertion fails or reliable arterial pressure monitoring cannot be maintained.
|
|
实验性的:Distal Radial Artery Group
Participants assigned to this arm will undergo ultrasound-guided distal radial arterial catheterization at a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal aspect of the hand.
|
Ultrasound-guided arterial catheterization will be performed at a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal aspect of the hand using standard sterile technique.
The insertion site will be selected according to vessel diameter, depth, and course on ultrasound.
A standard sterile disposable 20-gauge or 22-gauge over-the-needle arterial catheter will be used.
Up to three skin puncture attempts will be permitted.
After insertion, the catheter will be connected to the pressure monitoring system, zeroed at the level of the right atrium, assessed using a fast-flush test, and secured with a transparent dressing and tape.
Routine prophylactic wrist-extension splinting will not be applied.
Rescue catheterization may be performed according to standard clinical practice if insertion fails or reliable arterial pressure monitoring cannot be maintained.
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Number of Participants With Clinically Significant Arterial Catheter Dysfunction Requiring Troubleshooting or Rescue Intervention
大体时间:From completion of bilateral arm tucking until robot undocking or release of the arm-tucked position during surgery
|
Number of participants experiencing at least one clinically significant arterial catheter dysfunction event during the arm-tucked observation period.
An event is defined as: arterial pressure waveform damping or loss lasting at least 20 seconds; a difference of at least 20 mmHg between invasive and noninvasive systolic blood pressure measured simultaneously or within 1 minute when catheter dysfunction requires assessment or treatment; inability or clear resistance when aspirating blood; suspected catheter kinking or external compression requiring assessment; or the need for flushing, pressure line assessment, dressing adjustment, hand or wrist repositioning, wrist splint application, arm untucking, catheter replacement, or alternative arterial access.
Transient changes during planned blood sampling, fast-flush testing, zeroing, or transducer adjustment are counted only if they persist for at least 20 seconds afterward or require additional intervention.
|
From completion of bilateral arm tucking until robot undocking or release of the arm-tucked position during surgery
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- DRA-stability
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.