Distal Versus Conventional Radial Arterial Catheterization for Arterial Waveform Stability (DRA-stability)

2 août 2026 mis à jour par: Tae Kyong Kim, Seoul National University Hospital

Distal Versus Conventional Radial Arterial Catheterization for Arterial Waveform Stability During Arm-Tucked Robotic Urologic Surgery: A Prospective Randomized Controlled Study

During robot-assisted urologic surgery, both arms are often placed alongside the body and covered by surgical drapes. This position can make the arterial catheter difficult to access during surgery. A conventional radial arterial catheter placed at the wrist may become compressed or bent because of wrist position or arm fixation, which can cause an inaccurate or dampened arterial blood pressure waveform. A distal radial arterial catheter may be less affected by wrist movement or pressure on the forearm.

This single-center randomized study will include 70 adults undergoing robot-assisted urologic surgery under general anesthesia who require invasive arterial blood pressure monitoring. Participants will be randomly assigned in a 1:1 ratio to ultrasound-guided conventional radial arterial catheterization at the wrist or distal radial arterial catheterization near the anatomical snuffbox or back of the hand.

The main purpose of the study is to determine whether distal radial arterial catheterization reduces clinically significant arterial catheter dysfunction requiring troubleshooting or rescue treatment while the arms are tucked. The study will also compare catheter insertion success, first-attempt success, insertion time, episodes of dampened or lost arterial pressure waveforms, difficulty obtaining arterial blood samples, need for catheter replacement or another arterial access site, and catheter-related complications.

Aperçu de l'étude

Description détaillée

Invasive arterial blood pressure monitoring allows continuous assessment of blood pressure and repeated arterial blood sampling during general anesthesia. The conventional radial artery at the wrist is commonly used for arterial catheterization. However, wrist flexion or extension, arm fixation, surgical drapes, and external pressure may compress or bend the catheter and result in damping or loss of the arterial pressure waveform.

During robot-assisted urologic surgery, both arms are commonly tucked alongside the body. After surgical positioning and robot docking, direct access to the arterial catheter may be limited. A distal radial arterial catheter placed near the anatomical snuffbox or on the dorsal aspect of the hand is located distal to the wrist joint and may therefore be less affected by wrist position and forearm compression.

This is a single-center, prospective, randomized, open-label, superiority study. Seventy adult participants undergoing robot-assisted urologic surgery under general anesthesia and requiring invasive arterial pressure monitoring will be randomly assigned in a 1:1 ratio to conventional radial arterial catheterization or distal radial arterial catheterization. Randomization will be performed using a computer-generated block randomization sequence after written informed consent and confirmation of eligibility.

Both procedures will be performed under ultrasound guidance using standard sterile technique and a standard 20-gauge or 22-gauge over-the-needle arterial catheter. In the conventional radial artery group, the catheter will be inserted at the wrist, approximately 1 to 2 cm proximal to the radial styloid. In the distal radial artery group, the catheter will be inserted into a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal hand. Up to three skin puncture attempts will be permitted. If catheter insertion is unsuccessful or further attempts are considered inappropriate, rescue arterial catheterization will be performed according to standard clinical practice.

Routine prophylactic wrist-extension splints will not be applied in either group. Additional fixation, repositioning, catheter replacement, or other corrective measures may be performed at any time if required for reliable blood pressure monitoring or participant safety. The observation period will begin after both arms have been tucked and will continue until robot undocking or release of the arm-tucked position.

The primary objective is to compare the occurrence of clinically significant arterial catheter dysfunction requiring troubleshooting or rescue intervention during the observation period. Such dysfunction may include persistent damping or loss of the arterial waveform, clinically relevant disagreement between invasive and noninvasive blood pressure measurements, inability to aspirate blood, suspected catheter kinking or compression, or the need for interventions such as flushing, line assessment, dressing adjustment, hand or wrist repositioning, arm untucking, splint application, catheter replacement, or alternative arterial access.

Secondary assessments will include overall and first-attempt insertion success, insertion time, number and duration of waveform damping or loss episodes, difficulty with arterial blood aspiration, need for rescue catheterization, and the procedural burden of maintaining reliable arterial pressure monitoring. Safety assessments will include bleeding, hematoma, vasospasm, infection, pain or sensory symptoms, signs of hand ischemia, suspected radial artery occlusion, catheter replacement, and other unexpected adverse events. Clinically necessary treatment will not be delayed or restricted by study procedures.

Type d'étude

Interventionnel

Inscription (Estimé)

70

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

  • Nom: Tae Kyong Kim
  • Numéro de téléphone: 82-2-870-2519
  • E-mail: tk99@snu.ac.kr

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte
  • Adulte plus âgé

Accepte les volontaires sains

Non

La description

Inclusion Criteria:

  • Adults aged 19 years or older
  • Scheduled to undergo robot-assisted urologic surgery under general anesthesia
  • Scheduled to have both arms positioned alongside the body in an arm-tucked position during surgery
  • Considered by the attending anesthesiologist to require intraoperative invasive arterial blood pressure monitoring
  • Able and willing to provide written informed consent

Exclusion Criteria:

  • Refusal to participate or inability to provide written informed consent
  • Emergency surgery
  • Pregnancy or breastfeeding
  • Lack of decision-making capacity requiring consent from a legally authorized representative
  • Presence of an arteriovenous fistula for dialysis or unsuitable bilateral radial artery access
  • Infection, burn, trauma, surgical scar, or severe skin lesion at the intended puncture site
  • Suspected hand perfusion impairment, including radial artery occlusion, absent radial pulse, severe peripheral vascular disease, or Raynaud phenomenon
  • Severe coagulopathy or uncorrected bleeding tendency for which radial arterial catheterization is considered inappropriate
  • Any condition for which the attending anesthesiologist considers study participation inappropriate for participant safety

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Autre
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Comparateur actif: Conventional Radial Artery Group
Participants assigned to this arm will undergo ultrasound-guided conventional radial arterial catheterization at the wrist, approximately 1 to 2 cm proximal to the radial styloid.
Ultrasound-guided arterial catheterization will be performed at the conventional radial artery at the wrist, approximately 1 to 2 cm proximal to the radial styloid, using standard sterile technique. A standard sterile disposable 20-gauge or 22-gauge over-the-needle arterial catheter will be selected according to vessel diameter, depth, and clinical judgment. Up to three skin puncture attempts will be permitted. After insertion, the catheter will be connected to the pressure monitoring system, zeroed at the level of the right atrium, assessed using a fast-flush test, and secured with a transparent dressing and tape. Routine prophylactic wrist-extension splinting will not be applied. Rescue catheterization may be performed according to standard clinical practice if insertion fails or reliable arterial pressure monitoring cannot be maintained.
Expérimental: Distal Radial Artery Group
Participants assigned to this arm will undergo ultrasound-guided distal radial arterial catheterization at a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal aspect of the hand.
Ultrasound-guided arterial catheterization will be performed at a suitable segment of the distal radial artery in the anatomical snuffbox or dorsal aspect of the hand using standard sterile technique. The insertion site will be selected according to vessel diameter, depth, and course on ultrasound. A standard sterile disposable 20-gauge or 22-gauge over-the-needle arterial catheter will be used. Up to three skin puncture attempts will be permitted. After insertion, the catheter will be connected to the pressure monitoring system, zeroed at the level of the right atrium, assessed using a fast-flush test, and secured with a transparent dressing and tape. Routine prophylactic wrist-extension splinting will not be applied. Rescue catheterization may be performed according to standard clinical practice if insertion fails or reliable arterial pressure monitoring cannot be maintained.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Number of Participants With Clinically Significant Arterial Catheter Dysfunction Requiring Troubleshooting or Rescue Intervention
Délai: From completion of bilateral arm tucking until robot undocking or release of the arm-tucked position during surgery
Number of participants experiencing at least one clinically significant arterial catheter dysfunction event during the arm-tucked observation period. An event is defined as: arterial pressure waveform damping or loss lasting at least 20 seconds; a difference of at least 20 mmHg between invasive and noninvasive systolic blood pressure measured simultaneously or within 1 minute when catheter dysfunction requires assessment or treatment; inability or clear resistance when aspirating blood; suspected catheter kinking or external compression requiring assessment; or the need for flushing, pressure line assessment, dressing adjustment, hand or wrist repositioning, wrist splint application, arm untucking, catheter replacement, or alternative arterial access. Transient changes during planned blood sampling, fast-flush testing, zeroing, or transducer adjustment are counted only if they persist for at least 20 seconds afterward or require additional intervention.
From completion of bilateral arm tucking until robot undocking or release of the arm-tucked position during surgery

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Estimé)

5 août 2026

Achèvement primaire (Estimé)

31 juillet 2027

Achèvement de l'étude (Estimé)

31 décembre 2027

Dates d'inscription aux études

Première soumission

23 juillet 2026

Première soumission répondant aux critères de contrôle qualité

23 juillet 2026

Première publication (Réel)

28 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 août 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

2 août 2026

Dernière vérification

1 août 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • DRA-stability

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .