此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Internal Jugular Vein Respiratory Variability as a Marker of Disease Severity in Infant Bronchiolitis (IJV-BRONCH)

2026年8月20日 更新者:Emre Güngör、Eskisehir Osmangazi University

Respiratory Variation of Internal Jugular Vein Diameter as a Novel Ultrasonographic Marker of Disease Severity in Infants With Acute Bronchiolitis: A Prospective Observational Cohort Study

This prospective observational cohort study evaluates whether respiratory-cycle variation in internal jugular vein (IJV) diameter, measured by point-of-care ultrasound, correlates with clinical disease severity in infants 1-23 months of age presenting with acute bronchiolitis. Using a standardized M-mode protocol, the IJV Variability Index ([IJVmax-IJVmin]/IJVmax x 100) will be calculated and compared with the Wang Bronchiolitis Severity Score, four additional validated clinical severity instruments (Modified Tal Score, Respiratory Distress Assessment Instrument, Kristjansson Respiratory Score, Respiratory Assessment Change Score), oxygen saturation, respiratory rate, need for high-flow nasal cannula or supplemental oxygen, pediatric intensive care unit admission, and length of hospital stay. Concurrent lung and diaphragm point-of-care ultrasound will be performed to build a multimodal ultrasound severity model. No intervention is assigned; all ultrasound assessments are performed in addition to standard clinical care and do not alter treatment decisions.

研究概览

详细说明

Bronchiolitis is among the leading causes of hospitalization in infants under 2 years of age. Existing clinical severity scores show limited inter-observer agreement and weak correlation with oxygenation. Point-of-care ultrasound (lung ultrasound, diaphragm ultrasound) has been studied as an adjunct severity marker in bronchiolitis. Still, respiratory-cycle variability of the internal jugular vein (IJV) diameter has not previously been investigated in this population. A prior reliability study in healthy children demonstrated that right internal jugular vein (RIJV) diameter can be reliably measured by M-mode ultrasound and does not vary significantly across the respiratory cycle in the absence of respiratory distress; the study authors explicitly proposed that RIJV diameter and its respiratory variation be investigated as a surrogate marker of pulmonary function in children with respiratory distress. This study extends that proposed application to infants with acute bronchiolitis. Eligible infants aged 1-23 months meeting AAP (2014) clinical criteria for acute bronchiolitis will undergo a standardized ultrasound protocol (45-degree head elevation, linear probe, right internal jugular vein imaged approximately 1 cm cephalad to the sternoclavicular junction, B-mode identification followed by M-mode measurement of maximal inspiratory and expiratory diameters) performed by a blinded, trained sonographer. We will record concurrent clinical severity scoring, lung ultrasound, and diaphragm ultrasound (excursion, thickening fraction). The primary analysis will test the correlation between the IJV Variability Index and the Wang Bronchiolitis Severity Score; secondary analyses will examine correlations with additional validated severity scores, physiologic parameters, and clinical outcomes (respiratory support escalation, length of stay), as well as inter-/intra-observer reliability and the discriminative performance of a multimodal point-of-care ultrasound model.

研究类型

观察性的

注册 (估计的)

120

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

学习地点

    • Eskişehir
      • Eskişehir、Eskişehir、土耳其(türkiye)、26480
        • Eskisehir Osmangazi University Faculty of Medicine, Pediatric Emergency Department
        • 接触:

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 孩子

接受健康志愿者

不

取样方法

非概率样本

研究人群

Infants aged 1 to 23 months presenting to the Pediatric Emergency Department with a clinical diagnosis of acute bronchiolitis according to the American Academy of Pediatrics (AAP) clinical criteria will be prospectively enrolled. Eligible participants will be evaluated within the first 6 hours of emergency department presentation after written informed consent is obtained from a parent or legal guardian. Participants will undergo standardized clinical severity assessment and point-of-care ultrasonography of the internal jugular vein, lungs, and diaphragm in addition to routine clinical care. No study-specific therapeutic intervention will be assigned.

描述

Inclusion Criteria:

  • Infants aged 1-23 months
  • Clinical diagnosis of acute bronchiolitis per AAP (2014) criteria (first wheezing episode following an upper respiratory infection prodrome, with tachypnea, retractions, and/or crackles)
  • Written informed consent obtained from parent/legal guardian
  • Evaluable within the first 6 hours of emergency department presentation

Exclusion Criteria:

  • Underlying congenital heart disease
  • Chronic lung disease (bronchopulmonary dysplasia, cystic fibrosis)
  • Prior history of recurrent wheezing/suspected asthma
  • Anatomical abnormality of the neck or prior history of central venous catheterization or jugular vein thrombosis
  • Hemodynamic instability/shock
  • Immediate need for intubation/mechanical ventilation precluding ultrasound assessment
  • Parent/legal guardian declines consent

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

队列和干预

团体/队列
干预/治疗
Acute Bronchiolitis Cohort
Infants aged 1-23 months diagnosed with acute bronchiolitis per AAP (2014) clinical practice guideline criteria, undergoing a standardized point-of-care ultrasound assessment (internal jugular vein, lung, and diaphragm) in addition to standard clinical evaluation and treatment. No intervention is assigned as part of this study; the cohort will be stratified post hoc by clinical severity scores for descriptive and exploratory subgroup analyses.
A standardized point-of-care ultrasonography assessment will be performed in addition to routine clinical evaluation. The protocol includes M-mode assessment of the right internal jugular vein (IJV) to measure maximal and minimal respiratory-cycle diameters and calculate the IJV Variability Index ([IJVmax-IJVmin]/IJVmax × 100). Concurrent lung ultrasonography and diaphragm ultrasonography, including diaphragm excursion and thickening fraction, will also be performed. Ultrasonographic assessments are performed for research measurements only and do not determine or modify clinical treatment decisions.
其他名称:
  • 关注点

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Correlation Between Internal Jugular Vein Respiratory Variability Index and Wang Bronchiolitis Severity Score
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the Internal Jugular Vein (IJV) Variability Index and the Wang Bronchiolitis Severity Score. The IJV Variability Index will be calculated as ([IJVmax - IJVmin] / IJVmax) × 100, where IJVmax and IJVmin represent the maximum and minimum IJV diameters measured during the respiratory cycle. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater disease severity. The association will be quantified using Pearson or Spearman correlation coefficients, as appropriate.
At enrollment (baseline, within 6 hours of emergency department presentation)

次要结果测量

结果测量
措施说明
大体时间
Correlation Between IJV Variability Index and Oxygen Saturation, Respiratory Rate, and Retraction Severity
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and oxygen saturation (SpO2, %), respiratory rate (breaths/minute), and the retraction component of the Wang Bronchiolitis Severity Score. The retraction component ranges from 0 to 3, with higher scores indicating more severe retractions.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Need for High-Flow Nasal Cannula or Supplemental Oxygen Therapy
大体时间:From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants who require and do not require high-flow nasal cannula (HFNC) or supplemental oxygen therapy during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Association Between IJV Variability Index and Pediatric Intensive Care Unit Admission
大体时间:From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants admitted and not admitted to the pediatric intensive care unit (PICU) during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Correlation Between Diaphragm Ultrasound Parameters and IJV Variability Index and Clinical Severity Scores
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation of diaphragm excursion, diaphragm thickening fraction, and inspiratory/expiratory ratio with the IJV Variability Index and clinical severity scores. Clinical severity measures will include the Wang Bronchiolitis Severity Score (range 0-12), Modified Tal Score (range 0-12), Respiratory Distress Assessment Instrument (range 0-17), and Kristjansson Respiratory Score (range 0-10). For all four clinical severity scores, higher scores indicate greater disease or respiratory distress severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Modified Tal Score
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Modified Tal Score. The Modified Tal Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Respiratory Distress Assessment Instrument
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Respiratory Distress Assessment Instrument (RDAI). The RDAI assesses wheezing and retractions and ranges from 0 to 17, with higher scores indicating greater respiratory distress.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Respiratory Assessment Change Score
大体时间:Baseline and 2-4 hours after enrollment
Association between the baseline IJV Variability Index and the Respiratory Assessment Change Score (RACS). RACS quantifies change in respiratory status using the change in the Respiratory Distress Assessment Instrument together with a standardized change in respiratory rate between baseline and follow-up assessment. RACS is a change measure rather than a bounded scale and therefore does not have a fixed theoretical minimum or maximum.
Baseline and 2-4 hours after enrollment
Correlation Between IJV Variability Index and Kristjansson Respiratory Score
大体时间:At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Kristjansson Respiratory Score. The Kristjansson Respiratory Score ranges from 0 to 10, with higher scores indicating greater respiratory disease severity.
At enrollment (baseline, within 6 hours of emergency department presentation)

其他结果措施

结果测量
措施说明
大体时间
Discriminative Performance of a Multimodal Point-of-Care Ultrasound Model Versus Wang Bronchiolitis Severity Score for Predicting Escalated Respiratory Support
大体时间:From enrollment through 24 hours after enrollment
Area under the receiver operating characteristic curve (AUC, 95% confidence interval) for a multimodal model combining baseline IJV Variability Index, lung ultrasound score, and diaphragm ultrasound parameters, compared with the Wang Bronchiolitis Severity Score alone using the DeLong test. The lung ultrasound score ranges from 0 to 36, with higher scores indicating greater pulmonary aeration abnormality. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
From enrollment through 24 hours after enrollment

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

调查人员

  • 首席研究员:Emre Güngör, Medical Doctor、Eskisehir Osmangazi University Faculty of Medicine, Department of Pediatrics, Division of Pediatric Emergency Medicine

出版物和有用的链接

负责输入研究信息的人员自愿提供这些出版物。这些可能与研究有关。

一般刊物

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (估计的)

2026年9月1日

初级完成 (估计的)

2027年3月31日

研究完成 (估计的)

2027年8月31日

研究注册日期

首次提交

2026年8月15日

首先提交符合 QC 标准的

2026年8月20日

首次发布 (实际的)

2026年8月21日

研究记录更新

最后更新发布 (实际的)

2026年8月21日

上次提交的符合 QC 标准的更新

2026年8月20日

最后验证

2026年8月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

IPD 计划说明

The plan for sharing de-identified individual participant data has not yet been finalized. A data-sharing decision will be made before publication, taking into account participant confidentiality, ethics committee requirements, institutional policies, and applicable data protection regulations.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅