Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

Internal Jugular Vein Respiratory Variability as a Marker of Disease Severity in Infant Bronchiolitis (IJV-BRONCH)

20. august 2026 oppdatert av: Emre Güngör, Eskisehir Osmangazi University

Respiratory Variation of Internal Jugular Vein Diameter as a Novel Ultrasonographic Marker of Disease Severity in Infants With Acute Bronchiolitis: A Prospective Observational Cohort Study

This prospective observational cohort study evaluates whether respiratory-cycle variation in internal jugular vein (IJV) diameter, measured by point-of-care ultrasound, correlates with clinical disease severity in infants 1-23 months of age presenting with acute bronchiolitis. Using a standardized M-mode protocol, the IJV Variability Index ([IJVmax-IJVmin]/IJVmax x 100) will be calculated and compared with the Wang Bronchiolitis Severity Score, four additional validated clinical severity instruments (Modified Tal Score, Respiratory Distress Assessment Instrument, Kristjansson Respiratory Score, Respiratory Assessment Change Score), oxygen saturation, respiratory rate, need for high-flow nasal cannula or supplemental oxygen, pediatric intensive care unit admission, and length of hospital stay. Concurrent lung and diaphragm point-of-care ultrasound will be performed to build a multimodal ultrasound severity model. No intervention is assigned; all ultrasound assessments are performed in addition to standard clinical care and do not alter treatment decisions.

Studieoversikt

Detaljert beskrivelse

Bronchiolitis is among the leading causes of hospitalization in infants under 2 years of age. Existing clinical severity scores show limited inter-observer agreement and weak correlation with oxygenation. Point-of-care ultrasound (lung ultrasound, diaphragm ultrasound) has been studied as an adjunct severity marker in bronchiolitis. Still, respiratory-cycle variability of the internal jugular vein (IJV) diameter has not previously been investigated in this population. A prior reliability study in healthy children demonstrated that right internal jugular vein (RIJV) diameter can be reliably measured by M-mode ultrasound and does not vary significantly across the respiratory cycle in the absence of respiratory distress; the study authors explicitly proposed that RIJV diameter and its respiratory variation be investigated as a surrogate marker of pulmonary function in children with respiratory distress. This study extends that proposed application to infants with acute bronchiolitis. Eligible infants aged 1-23 months meeting AAP (2014) clinical criteria for acute bronchiolitis will undergo a standardized ultrasound protocol (45-degree head elevation, linear probe, right internal jugular vein imaged approximately 1 cm cephalad to the sternoclavicular junction, B-mode identification followed by M-mode measurement of maximal inspiratory and expiratory diameters) performed by a blinded, trained sonographer. We will record concurrent clinical severity scoring, lung ultrasound, and diaphragm ultrasound (excursion, thickening fraction). The primary analysis will test the correlation between the IJV Variability Index and the Wang Bronchiolitis Severity Score; secondary analyses will examine correlations with additional validated severity scores, physiologic parameters, and clinical outcomes (respiratory support escalation, length of stay), as well as inter-/intra-observer reliability and the discriminative performance of a multimodal point-of-care ultrasound model.

Studietype

Observasjonsmessig

Registrering (Antatt)

120

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

    • Eskişehir
      • Eskişehir, Eskişehir, Tyrkia (Türkiye), 26480
        • Eskisehir Osmangazi University Faculty of Medicine, Pediatric Emergency Department
        • Ta kontakt med:

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn

Tar imot friske frivillige

Nei

Prøvetakingsmetode

Ikke-sannsynlighetsprøve

Studiepopulasjon

Infants aged 1 to 23 months presenting to the Pediatric Emergency Department with a clinical diagnosis of acute bronchiolitis according to the American Academy of Pediatrics (AAP) clinical criteria will be prospectively enrolled. Eligible participants will be evaluated within the first 6 hours of emergency department presentation after written informed consent is obtained from a parent or legal guardian. Participants will undergo standardized clinical severity assessment and point-of-care ultrasonography of the internal jugular vein, lungs, and diaphragm in addition to routine clinical care. No study-specific therapeutic intervention will be assigned.

Beskrivelse

Inclusion Criteria:

  • Infants aged 1-23 months
  • Clinical diagnosis of acute bronchiolitis per AAP (2014) criteria (first wheezing episode following an upper respiratory infection prodrome, with tachypnea, retractions, and/or crackles)
  • Written informed consent obtained from parent/legal guardian
  • Evaluable within the first 6 hours of emergency department presentation

Exclusion Criteria:

  • Underlying congenital heart disease
  • Chronic lung disease (bronchopulmonary dysplasia, cystic fibrosis)
  • Prior history of recurrent wheezing/suspected asthma
  • Anatomical abnormality of the neck or prior history of central venous catheterization or jugular vein thrombosis
  • Hemodynamic instability/shock
  • Immediate need for intubation/mechanical ventilation precluding ultrasound assessment
  • Parent/legal guardian declines consent

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

Kohorter og intervensjoner

Gruppe / Kohort
Intervensjon / Behandling
Acute Bronchiolitis Cohort
Infants aged 1-23 months diagnosed with acute bronchiolitis per AAP (2014) clinical practice guideline criteria, undergoing a standardized point-of-care ultrasound assessment (internal jugular vein, lung, and diaphragm) in addition to standard clinical evaluation and treatment. No intervention is assigned as part of this study; the cohort will be stratified post hoc by clinical severity scores for descriptive and exploratory subgroup analyses.
A standardized point-of-care ultrasonography assessment will be performed in addition to routine clinical evaluation. The protocol includes M-mode assessment of the right internal jugular vein (IJV) to measure maximal and minimal respiratory-cycle diameters and calculate the IJV Variability Index ([IJVmax-IJVmin]/IJVmax × 100). Concurrent lung ultrasonography and diaphragm ultrasonography, including diaphragm excursion and thickening fraction, will also be performed. Ultrasonographic assessments are performed for research measurements only and do not determine or modify clinical treatment decisions.
Andre navn:
  • POKUS

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Correlation Between Internal Jugular Vein Respiratory Variability Index and Wang Bronchiolitis Severity Score
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the Internal Jugular Vein (IJV) Variability Index and the Wang Bronchiolitis Severity Score. The IJV Variability Index will be calculated as ([IJVmax - IJVmin] / IJVmax) × 100, where IJVmax and IJVmin represent the maximum and minimum IJV diameters measured during the respiratory cycle. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater disease severity. The association will be quantified using Pearson or Spearman correlation coefficients, as appropriate.
At enrollment (baseline, within 6 hours of emergency department presentation)

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Correlation Between IJV Variability Index and Oxygen Saturation, Respiratory Rate, and Retraction Severity
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and oxygen saturation (SpO2, %), respiratory rate (breaths/minute), and the retraction component of the Wang Bronchiolitis Severity Score. The retraction component ranges from 0 to 3, with higher scores indicating more severe retractions.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Need for High-Flow Nasal Cannula or Supplemental Oxygen Therapy
Tidsramme: From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants who require and do not require high-flow nasal cannula (HFNC) or supplemental oxygen therapy during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Association Between IJV Variability Index and Pediatric Intensive Care Unit Admission
Tidsramme: From enrollment through hospital discharge, assessed up to approximately 7 days
Comparison of baseline IJV Variability Index between infants admitted and not admitted to the pediatric intensive care unit (PICU) during hospitalization.
From enrollment through hospital discharge, assessed up to approximately 7 days
Correlation Between Diaphragm Ultrasound Parameters and IJV Variability Index and Clinical Severity Scores
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation of diaphragm excursion, diaphragm thickening fraction, and inspiratory/expiratory ratio with the IJV Variability Index and clinical severity scores. Clinical severity measures will include the Wang Bronchiolitis Severity Score (range 0-12), Modified Tal Score (range 0-12), Respiratory Distress Assessment Instrument (range 0-17), and Kristjansson Respiratory Score (range 0-10). For all four clinical severity scores, higher scores indicate greater disease or respiratory distress severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Modified Tal Score
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Modified Tal Score. The Modified Tal Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation Between IJV Variability Index and Respiratory Distress Assessment Instrument
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Respiratory Distress Assessment Instrument (RDAI). The RDAI assesses wheezing and retractions and ranges from 0 to 17, with higher scores indicating greater respiratory distress.
At enrollment (baseline, within 6 hours of emergency department presentation)
Association Between IJV Variability Index and Respiratory Assessment Change Score
Tidsramme: Baseline and 2-4 hours after enrollment
Association between the baseline IJV Variability Index and the Respiratory Assessment Change Score (RACS). RACS quantifies change in respiratory status using the change in the Respiratory Distress Assessment Instrument together with a standardized change in respiratory rate between baseline and follow-up assessment. RACS is a change measure rather than a bounded scale and therefore does not have a fixed theoretical minimum or maximum.
Baseline and 2-4 hours after enrollment
Correlation Between IJV Variability Index and Kristjansson Respiratory Score
Tidsramme: At enrollment (baseline, within 6 hours of emergency department presentation)
Correlation between the IJV Variability Index and the Kristjansson Respiratory Score. The Kristjansson Respiratory Score ranges from 0 to 10, with higher scores indicating greater respiratory disease severity.
At enrollment (baseline, within 6 hours of emergency department presentation)

Andre resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Discriminative Performance of a Multimodal Point-of-Care Ultrasound Model Versus Wang Bronchiolitis Severity Score for Predicting Escalated Respiratory Support
Tidsramme: From enrollment through 24 hours after enrollment
Area under the receiver operating characteristic curve (AUC, 95% confidence interval) for a multimodal model combining baseline IJV Variability Index, lung ultrasound score, and diaphragm ultrasound parameters, compared with the Wang Bronchiolitis Severity Score alone using the DeLong test. The lung ultrasound score ranges from 0 to 36, with higher scores indicating greater pulmonary aeration abnormality. The Wang Bronchiolitis Severity Score ranges from 0 to 12, with higher scores indicating greater bronchiolitis severity.
From enrollment through 24 hours after enrollment

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Etterforskere

  • Hovedetterforsker: Emre Güngör, Medical Doctor, Eskisehir Osmangazi University Faculty of Medicine, Department of Pediatrics, Division of Pediatric Emergency Medicine

Publikasjoner og nyttige lenker

Den som er ansvarlig for å legge inn informasjon om studien leverer frivillig disse publikasjonene. Disse kan handle om alt relatert til studiet.

Generelle publikasjoner

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. september 2026

Primær fullføring (Antatt)

31. mars 2027

Studiet fullført (Antatt)

31. august 2027

Datoer for studieregistrering

Først innsendt

15. august 2026

Først innsendt som oppfylte QC-kriteriene

20. august 2026

Først lagt ut (Faktiske)

21. august 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

21. august 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

20. august 2026

Sist bekreftet

1. august 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

UBESLUTTE

IPD-planbeskrivelse

The plan for sharing de-identified individual participant data has not yet been finalized. A data-sharing decision will be made before publication, taking into account participant confidentiality, ethics committee requirements, institutional policies, and applicable data protection regulations.

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere