此页面是自动翻译的,不保证翻译的准确性。请参阅 英文版 对于源文本。

Acute Responses to Walking, Stair Climbing, and Functional Circuit Exercise

2026年9月4日 更新者:Ramazan Bayer、Malatya Turgut Ozal University

Acute Metabolic, Respiratory, and Neuromotor Responses to Walking, Stair Climbing, and Functional Circuit Exercise in Sedentary Individuals: A Heart Rate-Controlled Randomized Crossover Study

This study evaluated the acute physiological responses to three different exercise modalities in sedentary young men. Participants completed walking, stair climbing, and functional circuit exercise sessions in a randomized crossover design. Each exercise session lasted 20 minutes and was performed at a target intensity of 50% heart rate reserve (±5 beats/min), with at least 72 hours between sessions.

The study compared acute respiratory, metabolic, and neuromotor responses to the three exercise modalities. Pulmonary function was assessed using spirometry, blood lactate concentration was measured using capillary blood samples, and countermovement jump performance was assessed as an indicator of neuromuscular performance. Heart rate was continuously monitored during each exercise session.

研究概览

研究类型

介入性

注册 (实际的)

30

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习地点

    • Malatya
      • Malatya、Malatya、土耳其(türkiye)、44100
        • Malatya Turgut Ozal University

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

  • 成人

接受健康志愿者

是的

描述

Inclusion Criteria:

  • Male sex.
  • Aged 18-30 years.
  • Classified as sedentary/insufficiently active according to the study eligibility criteria.
  • Able to safely complete the exercise protocols and study assessments.
  • Provided voluntary informed consent.

Exclusion Criteria:

  • Current cigarette or electronic cigarette use.
  • Known cardiovascular, respiratory, or metabolic disease.
  • Regular medication use that could affect physiological responses to exercise.
  • Acute infection within the previous 2 weeks.
  • Musculoskeletal conditions that could interfere with safe participation in the exercise protocols.
  • Any condition requiring medical evaluation before exercise participation.
  • Inability to obtain acceptable baseline spirometry measurements according to the study procedures.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:基础科学
  • 分配:随机化
  • 介入模型:交叉作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:WP-SP-FCP Sequence
Participants completed the Walking Protocol first, followed by the Stair Climbing Protocol and then the Functional Circuit Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP
实验性的:WP-FCP-SP Sequence
Participants completed the Walking Protocol first, followed by the Functional Circuit Protocol and then the Stair Climbing Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP
实验性的:SP-WP-FCP Sequence
Participants completed the Stair Climbing Protocol first, followed by the Walking Protocol and then the Functional Circuit Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP
实验性的:SP-FCP-WP Sequence
Participants completed the Stair Climbing Protocol first, followed by the Functional Circuit Protocol and then the Walking Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP
实验性的:FCP-WP-SP Sequence
Participants completed the Functional Circuit Protocol first, followed by the Walking Protocol and then the Stair Climbing Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP
实验性的:FCP-SP-WP Sequence
Participants completed the Functional Circuit Protocol first, followed by the Stair Climbing Protocol and then the Walking Protocol, with at least 72 hours between sessions.
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • 湿性粉剂
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • SP
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate. The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface. Heart rate was continuously monitored throughout the exercise session.
其他名称:
  • FCP

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Change in Forced Expiratory Volume in One Second (FEV1)
大体时间:Baseline and 5 minutes after each exercise session
Forced expiratory volume in one second (FEV1) was measured by spirometry before and 5 minutes after each exercise condition. The primary outcome was the change in FEV1 (ΔFEV1), calculated as post-exercise FEV1 minus pre-exercise FEV1 and expressed in liters (L). Measurements were obtained following standardized spirometry procedures.
Baseline and 5 minutes after each exercise session

次要结果测量

结果测量
措施说明
大体时间
Change in Forced Vital Capacity (FVC)
大体时间:Baseline and 5 minutes after each exercise session
Forced vital capacity (FVC) was measured by spirometry before and 5 minutes after each exercise condition. The outcome was the change in FVC (ΔFVC), calculated as post-exercise FVC minus pre-exercise FVC and expressed in liters (L).
Baseline and 5 minutes after each exercise session
Change in FEV1/FVC Ratio
大体时间:Baseline and 5 minutes after each exercise session
The FEV1/FVC ratio was assessed by spirometry before and 5 minutes after each exercise condition. The outcome was the change in FEV1/FVC ratio (ΔFEV1/FVC), calculated as the post-exercise value minus the pre-exercise value.
Baseline and 5 minutes after each exercise session
Change in Peak Expiratory Flow (PEF)
大体时间:Baseline and 5 minutes after each exercise session
Peak expiratory flow (PEF) was measured by spirometry before and 5 minutes after each exercise condition. The outcome was the change in PEF (ΔPEF), calculated as the post-exercise PEF minus the pre-exercise PEF and expressed in liters per second (L/s).
Baseline and 5 minutes after each exercise session
Change in Blood Lactate Concentration
大体时间:Baseline and 3 minutes after each exercise session
Capillary blood lactate concentration was measured before exercise and 3 minutes after each exercise condition. The outcome was the change in blood lactate concentration (ΔLactate), calculated as the post-exercise value minus the pre-exercise value and expressed in millimoles per liter (mmol/L).
Baseline and 3 minutes after each exercise session
Change in Countermovement Jump Height (CMJ)
大体时间:Baseline and immediately after post-exercise spirometry initiated at 5 minutes after each exercise session
Countermovement jump (CMJ) height was assessed before and after each exercise condition. The outcome was the change in CMJ height (ΔCMJ), calculated as the post-exercise value minus the pre-exercise value and expressed in centimeters (cm).
Baseline and immediately after post-exercise spirometry initiated at 5 minutes after each exercise session
Mean Heart Rate During Exercise
大体时间:During each 20-minute exercise session
Heart rate was continuously monitored throughout each exercise condition. Mean heart rate was calculated across the exercise period and expressed in beats per minute (bpm).
During each 20-minute exercise session
Maximum Heart Rate During Exercise
大体时间:During each 20-minute exercise session
Heart rate was continuously monitored throughout each exercise condition. Maximum heart rate was defined as the highest heart rate recorded during the exercise period and expressed in beats per minute (bpm).
During each 20-minute exercise session
Time Spent in the Target Heart Rate Range
大体时间:During each 20-minute exercise session
Heart rate was continuously monitored throughout each exercise condition. The outcome was the percentage of exercise time during which heart rate remained within ±5 beats/min of the individualized target heart rate corresponding to 50% heart rate reserve (HRR)
During each 20-minute exercise session

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年6月22日

初级完成 (实际的)

2026年8月5日

研究完成 (实际的)

2026年8月5日

研究注册日期

首次提交

2026年9月1日

首先提交符合 QC 标准的

2026年9月4日

首次发布 (实际的)

2026年9月8日

研究记录更新

最后更新发布 (实际的)

2026年9月8日

上次提交的符合 QC 标准的更新

2026年9月4日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

其他相关的 MeSH 术语

其他研究编号

  • 2026/205

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

不

IPD 计划说明

Individual participant data are not planned to be shared because no data-sharing plan was established as part of the original study protocol.

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅