- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT07806032
Acute Responses to Walking, Stair Climbing, and Functional Circuit Exercise
Acute Metabolic, Respiratory, and Neuromotor Responses to Walking, Stair Climbing, and Functional Circuit Exercise in Sedentary Individuals: A Heart Rate-Controlled Randomized Crossover Study
This study evaluated the acute physiological responses to three different exercise modalities in sedentary young men. Participants completed walking, stair climbing, and functional circuit exercise sessions in a randomized crossover design. Each exercise session lasted 20 minutes and was performed at a target intensity of 50% heart rate reserve (±5 beats/min), with at least 72 hours between sessions.
The study compared acute respiratory, metabolic, and neuromotor responses to the three exercise modalities. Pulmonary function was assessed using spirometry, blood lactate concentration was measured using capillary blood samples, and countermovement jump performance was assessed as an indicator of neuromuscular performance. Heart rate was continuously monitored during each exercise session.
Descripción general del estudio
Estado
Condiciones
Intervención / Tratamiento
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
Malatya
-
Malatya, Malatya, Turquía (Türkiye), 44100
- Malatya Turgut Ozal University
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
Acepta Voluntarios Saludables
Descripción
Inclusion Criteria:
- Male sex.
- Aged 18-30 years.
- Classified as sedentary/insufficiently active according to the study eligibility criteria.
- Able to safely complete the exercise protocols and study assessments.
- Provided voluntary informed consent.
Exclusion Criteria:
- Current cigarette or electronic cigarette use.
- Known cardiovascular, respiratory, or metabolic disease.
- Regular medication use that could affect physiological responses to exercise.
- Acute infection within the previous 2 weeks.
- Musculoskeletal conditions that could interfere with safe participation in the exercise protocols.
- Any condition requiring medical evaluation before exercise participation.
- Inability to obtain acceptable baseline spirometry measurements according to the study procedures.
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Ciencia básica
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación cruzada
- Enmascaramiento: Ninguno (etiqueta abierta)
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
|---|---|
|
Experimental: WP-SP-FCP Sequence
Participants completed the Walking Protocol first, followed by the Stair Climbing Protocol and then the Functional Circuit Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
|
Experimental: WP-FCP-SP Sequence
Participants completed the Walking Protocol first, followed by the Functional Circuit Protocol and then the Stair Climbing Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
|
Experimental: SP-WP-FCP Sequence
Participants completed the Stair Climbing Protocol first, followed by the Walking Protocol and then the Functional Circuit Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
|
Experimental: SP-FCP-WP Sequence
Participants completed the Stair Climbing Protocol first, followed by the Functional Circuit Protocol and then the Walking Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
|
Experimental: FCP-WP-SP Sequence
Participants completed the Functional Circuit Protocol first, followed by the Walking Protocol and then the Stair Climbing Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
|
Experimental: FCP-SP-WP Sequence
Participants completed the Functional Circuit Protocol first, followed by the Stair Climbing Protocol and then the Walking Protocol, with at least 72 hours between sessions.
|
Participants performed a 20-minute walking exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute stair climbing exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
Participants performed a 20-minute functional circuit exercise session at a target intensity of 50% heart rate reserve (HRR), maintained within ±5 beats/min of the individual target heart rate.
The circuit consisted of chair sit-to-stand, reverse lunges, wall push-ups, high-knee marching, and low-impact mountain climbers performed on an elevated surface.
Heart rate was continuously monitored throughout the exercise session.
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in Forced Expiratory Volume in One Second (FEV1)
Periodo de tiempo: Baseline and 5 minutes after each exercise session
|
Forced expiratory volume in one second (FEV1) was measured by spirometry before and 5 minutes after each exercise condition.
The primary outcome was the change in FEV1 (ΔFEV1), calculated as post-exercise FEV1 minus pre-exercise FEV1 and expressed in liters (L).
Measurements were obtained following standardized spirometry procedures.
|
Baseline and 5 minutes after each exercise session
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
Change in Forced Vital Capacity (FVC)
Periodo de tiempo: Baseline and 5 minutes after each exercise session
|
Forced vital capacity (FVC) was measured by spirometry before and 5 minutes after each exercise condition.
The outcome was the change in FVC (ΔFVC), calculated as post-exercise FVC minus pre-exercise FVC and expressed in liters (L).
|
Baseline and 5 minutes after each exercise session
|
|
Change in FEV1/FVC Ratio
Periodo de tiempo: Baseline and 5 minutes after each exercise session
|
The FEV1/FVC ratio was assessed by spirometry before and 5 minutes after each exercise condition.
The outcome was the change in FEV1/FVC ratio (ΔFEV1/FVC), calculated as the post-exercise value minus the pre-exercise value.
|
Baseline and 5 minutes after each exercise session
|
|
Change in Peak Expiratory Flow (PEF)
Periodo de tiempo: Baseline and 5 minutes after each exercise session
|
Peak expiratory flow (PEF) was measured by spirometry before and 5 minutes after each exercise condition.
The outcome was the change in PEF (ΔPEF), calculated as the post-exercise PEF minus the pre-exercise PEF and expressed in liters per second (L/s).
|
Baseline and 5 minutes after each exercise session
|
|
Change in Blood Lactate Concentration
Periodo de tiempo: Baseline and 3 minutes after each exercise session
|
Capillary blood lactate concentration was measured before exercise and 3 minutes after each exercise condition.
The outcome was the change in blood lactate concentration (ΔLactate), calculated as the post-exercise value minus the pre-exercise value and expressed in millimoles per liter (mmol/L).
|
Baseline and 3 minutes after each exercise session
|
|
Change in Countermovement Jump Height (CMJ)
Periodo de tiempo: Baseline and immediately after post-exercise spirometry initiated at 5 minutes after each exercise session
|
Countermovement jump (CMJ) height was assessed before and after each exercise condition.
The outcome was the change in CMJ height (ΔCMJ), calculated as the post-exercise value minus the pre-exercise value and expressed in centimeters (cm).
|
Baseline and immediately after post-exercise spirometry initiated at 5 minutes after each exercise session
|
|
Mean Heart Rate During Exercise
Periodo de tiempo: During each 20-minute exercise session
|
Heart rate was continuously monitored throughout each exercise condition.
Mean heart rate was calculated across the exercise period and expressed in beats per minute (bpm).
|
During each 20-minute exercise session
|
|
Maximum Heart Rate During Exercise
Periodo de tiempo: During each 20-minute exercise session
|
Heart rate was continuously monitored throughout each exercise condition.
Maximum heart rate was defined as the highest heart rate recorded during the exercise period and expressed in beats per minute (bpm).
|
During each 20-minute exercise session
|
|
Time Spent in the Target Heart Rate Range
Periodo de tiempo: During each 20-minute exercise session
|
Heart rate was continuously monitored throughout each exercise condition.
The outcome was the percentage of exercise time during which heart rate remained within ±5 beats/min of the individualized target heart rate corresponding to 50% heart rate reserve (HRR)
|
During each 20-minute exercise session
|
Colaboradores e Investigadores
Patrocinador
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 2026/205
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .