Impact of Stepwise Pressure-Increasing NC Balloon Post-Dilation on Stent Expansion (SPND)

2026年9月28日 更新者:Mingyou Zhang、Jilin University

This is a prospective, single-center, single-arm exploratory observational study aiming to evaluate the impact of stepwise pressure-increasing non-compliant (NC) balloon post-dilation on stent expansion rate in patients undergoing single-stent implantation for coronary artery stenosis, with stent sizing guided by intravascular ultrasound-external elastic membrane (IVUS-EEM) measurement.

A total of 150 eligible patients will be enrolled at The First Hospital of Jilin University. All participants will receive standard single-stent implantation followed by multi-stage stepwise pressure-increasing NC balloon post-dilation under IVUS monitoring. The post-dilation protocol includes sequential inflation at nominal pressure, rated burst pressure, and 24 atm, with IVUS assessment performed after each stage. All treatment procedures are conducted in accordance with routine clinical practice; no additional randomization or mandatory intervention is applied beyond the standard of care. The study solely observes and records outcomes associated with this treatment strategy.

研究概览

详细说明

Coronary atherosclerotic heart disease remains one of the leading causes of mortality and disability worldwide. Coronary stent implantation is a principal therapeutic strategy for coronary artery stenosis. The adequacy of stent expansion is a critical determinant of treatment efficacy; inadequate stent expansion may lead to stent malapposition, in-stent restenosis, stent thrombosis, and other adverse events that significantly compromise patient prognosis.

Intravascular ultrasound (IVUS), as an invasive vascular imaging modality, enables clear visualization of vessel wall architecture, plaque characteristics, and immediate post-stent implantation outcomes. Among its measurements, the external elastic membrane (EEM) cross-sectional area serves as a key reference for stent sizing, effectively overcoming the inherent limitation of conventional coronary angiography, which relies solely on luminal imaging for stent diameter selection.

Non-compliant (NC) balloon post-dilation is an essential step in optimizing stent implantation outcomes. Gradual incremental increases in balloon pressure may further promote adequate stent expansion and improve stent-vessel wall apposition. However, the specific impact of NC balloon post-dilation at different pressures and durations on stent expansion rate has not been systematically validated. To date, there remains a paucity of dedicated studies investigating the dynamic changes in stent expansion rate under a stepwise pressure-increasing protocol.

This study utilizes IVUS-EEM measurements to guide stent sizing and adopts a single-stent implantation strategy combined with multi-stage stepwise pressure-increasing NC balloon post-dilation. after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation. IVUS measurement will be made after each step and stent expansion and Minimal stent area will be documented.

Primary Endpoint. Minimum Stent Area (MSA)

IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation)

Secondary endpoints:

Stent Expansion Rate

IVUS-measured stent expansion rate immediately post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), calculated as: (minimum stent cross-sectional area [MSA] measured by IVUS / manufacturer's nominal MSA) × 100%.

rates of stent edge dissection, hematoma, perforation.

研究类型

介入性

注册 (估计的)

150

阶段

  • 不适用

联系人和位置

本节提供了进行研究的人员的详细联系信息,以及有关进行该研究的地点的信息。

学习联系方式

  • 姓名:Mingyou Zhang, M.D.
  • 电话号码:8613689842200
  • 邮箱:zmy@jlu.edu.cn

学习地点

    • Jilin
      • Changchun、Jilin、中国、130000
        • 招聘中
        • The First Hospital of Jilin University

参与标准

研究人员寻找符合特定描述的人,称为资格标准。这些标准的一些例子是一个人的一般健康状况或先前的治疗。

资格标准

适合学习的年龄

18年 及以上 (成人、年长者)

接受健康志愿者

不

有资格学习的性别

全部

描述

Inclusion Criteria:

  • Age ≥18 years regardless of gender;
  • Coronary angiography confirms single-vessel coronary artery stenosis ≥50%, meeting the indication for single-stent implantation;
  • Preoperative IVUS examination can clearly visualize the vessel EEM, allowing for stent size measurement and assessment of stent expansion-related parameters;
  • The patient voluntarily participates in this study and signs the informed consent form;
  • No contraindications related to IVUS examination, stent implantation, or balloon angioplasty.

Exclusion Criteria:

  • Hemodynamically unstable
  • Presence of anatomical or pathological factors preventing IVUS catheter crossing.

学习计划

本节提供研究计划的详细信息,包括研究的设计方式和研究的衡量标准。

研究是如何设计的?

设计细节

  • 主要用途:治疗
  • 分配:不适用
  • 介入模型:单组作业
  • 屏蔽:无(打开标签)

武器和干预

参与者组/臂
干预/治疗
实验性的:Serial pressure dilation

After stent nominal pressure deployment stent will be postdilated at 12atm*10s, 18atm *10s, 24atm*10s.Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.IVUS measurement will be done after each dilation for the MSA and stent expansion

Coronary stent implantation followed by serial pressure post-dilation using non-compliant balloon under IVUS guidance

研究衡量的是什么?

主要结果指标

结果测量
措施说明
大体时间
Minimum Stent Area (MSA)
大体时间:3 days

IVUS-measured minimum lumen cross-sectional area within the stented segment post-procedure (after stent deployment with norminal pressure, 12*10 atm, 18*10 atm and 24*10 atm NC balloon post-dilation), Final post-dilation will be attempted at 24 atm for up to 120 seconds, with the duration limited to the patient's maximum tolerated time if premature intolerance occurs.

3 days

合作者和调查者

在这里您可以找到参与这项研究的人员和组织。

研究记录日期

这些日期跟踪向 ClinicalTrials.gov 提交研究记录和摘要结果的进度。研究记录和报告的结果由国家医学图书馆 (NLM) 审查,以确保它们在发布到公共网站之前符合特定的质量控制标准。

研究主要日期

学习开始 (实际的)

2026年1月7日

初级完成 (估计的)

2026年12月30日

研究完成 (估计的)

2026年12月30日

研究注册日期

首次提交

2026年9月23日

首先提交符合 QC 标准的

2026年9月28日

首次发布 (实际的)

2026年10月1日

研究记录更新

最后更新发布 (实际的)

2026年10月1日

上次提交的符合 QC 标准的更新

2026年9月28日

最后验证

2026年9月1日

更多信息

与本研究相关的术语

计划个人参与者数据 (IPD)

计划共享个人参与者数据 (IPD)?

未定

药物和器械信息、研究文件

研究美国 FDA 监管的药品

不

研究美国 FDA 监管的设备产品

不

在美国制造并从美国出口的产品

不

此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.

订阅