Accelerated Breast Diffusion-weighted Imaging Using Multiband Sensitivity Encoding with the CAIPIRINHA Method: Clinical Experience at 3 T
Debosmita Biswas, Daniel S Hippe, Yi Wang, Michaela R DelPriore, Mladen Zečević, John R Scheel, Habib Rahbar, Savannah C Partridge, Debosmita Biswas, Daniel S Hippe, Yi Wang, Michaela R DelPriore, Mladen Zečević, John R Scheel, Habib Rahbar, Savannah C Partridge
Abstract
Purpose To examine the clinical value of multiband (MB) sensitivity encoding (SENSE)-accelerated diffusion-weighted imaging (DWI) for breast imaging by performing quantitative and qualitative comparisons with conventional diffusion-weighted echo-planar imaging, or conventional DWI (cDWI). Materials and Methods In this prospective study (ClinicalTrials.gov identifier NCT03607552), women with breast cancer were recruited from July 2018 to July 2019 to undergo additional MB SENSE DWI during clinical 3-T breast MRI examinations. The cDWI and MB SENSE DWI acquisitions were assessed both quantitatively and qualitatively. Regions of interest were defined for tumorous and normal tissue, and the tumor apparent diffusion coefficient (ADC), contrast-to-noise ratio (CNR), and signal index (SI) were calculated for both DWI methods. Three readers independently reviewed the two acquisitions side by side and provided relative image quality scores. Tumor ADC, CNR, and SI measures were compared between cDWI and MB SENSE DWI acquisitions by using a paired t test, and reader preferences were evaluated by using the sign test. Results The study included 38 women (median age, 48 years; range, 28-83 years). Overall agreement was good between cDWI and MB SENSE DWI tumor ADC measures (intraclass correlation coefficient, 0.87 [95% CI: 0.75, 0.94]), and no differences were evident in the ADC (median, 0.93 × 10-3 mm2/sec vs 0.87 ×10-3 mm2/sec; P = .50), CNR (2.2 vs 2.3; P = .17), or SI (9.2 vs 9.2; P = .23) measurements. The image quality of cDWI and MB SENSE DWI acquisitions were considered equal for 51% of images (58 of 114), whereas MB SENSE DWI was preferred more often than cDWI (37% [42 of 114] vs 12% [14 of 114]; P < .001). The preference for MB SENSE DWI was most often attributed to better fat suppression. Conclusion MB SENSE can be used to accelerate breast DWI acquisition times without compromising the image quality or the fidelity of quantitative ADC measurements. Keywords: MR-Diffusion-weighted Imaging, Breast, Comparative Studies, Technology Assessment Clinical trial registration no. NCT03607552 © RSNA, 2022.
Keywords: Breast; Comparative Studies; MR-Diffusion-weighted Imaging; Technology Assessment.
Conflict of interest statement
Disclosures of conflicts of interest: D.B. Support for present work from National Institutes of Health (NIH) (payments through institution), Philips Healthcare (in-kind support through institution), and Safeway Foundation (payments through institution). D.S.H. Support for present work from NIH grants (R01 CA207290, P30 CA015704) to institution; institution has grants from GE Healthcare, Philips Healthcare, Canon Medical Systems USA, and Siemens Healthineers. Y.W. No relevant relationships. M.R.D. In-kind support for present work from Philips Healthcare (use of the sequence); currently employed by Philips Healthcare (employment began after work on the present manuscript had concluded). M.Z. Research grant from GE Healthcare. J.R.S. Grants from Radiological Society of North America Global Oncology-Fred Hutchinson Cancer Research center and GE Healthcare, unrelated to the current work; leadership or fiduciary role in RAD-AID and Breast Health Global Initiative. H.R. Current work supported by NIH grant (R01CA207290), author is co-investigator; institution has grant from GE Healthcare, author is co-investigator, funding not related to this study. S.C.P. Current work supported by NIH grant (R01CA207290), author is principal investigator; institution has grant from GE Healthcare, author is co-investigator, funding not related to this study.
Figures





Source: PubMed
即将进行的临床试验
-
Shirley Ryan AbilityLabKiwanis Neurological Research Foundation招聘中
-
University of ChicagoNational Heart, Lung, and Blood Institute (NHLBI)尚未招聘
-
Fundacion para la Investigacion Biomedica del Hospital...Hospital Universitario La Fe招聘中
-
Lumetry Diagnostics GmbHKarl Landsteiner Institute for Lung Research and Pneumological Oncology; Klinik Floridsdorf尚未招聘
-
Beijing Suncadia Pharmaceuticals Co., Ltd招聘中
-
Xiangya Hospital of Central South University尚未招聘
-
Halic University尚未招聘睡眠质量 | 饮食干预 | 感知压力 | 脑雾土耳其(türkiye)
-
Sun Yat-Sen Memorial Hospital of Sun Yat-Sen University尚未招聘
-
The 108 Military Central HospitalVietnam Military Medical University; Thanh Phuong Co., Ltd尚未招聘
-
University Hospital, Montpellier尚未招聘
-
Kasr El Aini Hospital招聘中