Evaluation of Lung Doppler Signals in Patients Presenting to EMD

August 12, 2015 updated by: Echosense Ltd.

Evaluation of Lung Doppler Signals in Patients With Acute Cardiovascular or Pulmonary Conditions Presenting to the Emergency Medicine Department by a Modified Ultrasound Doppler TCD Device.

Historically, ultrasound has been unable to provide interpretable data from the lung parenchyma, mainly because of the high total ultrasound energy attenuation and scattering by the air in the lungs. Recently it has been shown that clear reproducible Doppler signals can be recorded from the lung parenchyma by means of a pulsed Doppler ultrasound system incorporating a special signal processing package (transthoracic parametric Doppler, TPD, EchoSense Ltd., Haifa, Israel). These lung Doppler signals (LDS) are in full synchrony with the cardiac cycle and can be obtained from the lungs, including areas remote from the heart and main pulmonary vessels. The LDS waves typically have peak velocities of up to 30 cm/s and are of relatively high power, making it possible to detect them despite the aforementioned attenuation by the air in the lungs. The LDS are thought to represent the radial wall movement of small pulmonary blood vessels, caused by pressure pulse waves of cardiac origin which propagate throughout the lung vasculature. The LDS may contain information of significant diagnostic and physiological value regarding the pulmonary parenchyma and vasculature, as well as the cardio-vascular system in general.

Preliminary data from ongoing studies employing the TPD in chronic diseases such as CHF, COPD and pulmonary hypertension, show promise regarding the diagnostic potential of the lung Doppler signals (unpublished data). However, lung Doppler signals in acute disease states were not investigated so far. It is reasonable to speculate that the pathological processes underlying acute cardiovascular and pulmonary diseases will affect the LDS. Therefore, the TPD may have diagnostic potential in these conditions. For example, during acute pulmonary embolism a portion of the pulmonary vascular system is occluded; therefore it's reasonable to assume that the LDS will disappear in the affected area, enabling to confirm the diagnosis without using ionizing radiation (as in CT or lung scan). Another example is COPD exacerbation, during which there is usually air trapping in the lungs; thus, the LDS may be attenuated by the increase of air volume in the lungs.

Study Overview

Detailed Description

A. Study Purpose and Rationale To evaluate the LDS in patients with various acute cardiovascular and/or pulmonary disease states, in order to characterize these signals and assess their diagnostic utility in those acute conditions.

B. Study Design

The study design is an open, prospective, non-interventional study. 100 patients will be recruited at the Rambam Emergency Medicine Department (EMD) during an 18 month period.

Study population will consist of patients presenting to the EMD with acute cardiovascular and/or pulmonary conditions, including- but not restricted to- pneumonia, pulmonary embolism, CHF exacerbation, COPD exacerbation, shock, etc. Following informed consent and applying the inclusion and exclusion criteria, the eligible patients will undergo routine physical examination including vital signs measurement (blood pressure, heart rate, respiratory rate, O2 saturation by pulse oximetry), and auscultation to lungs. The patient would also undergo ECG and chest X-ray as part of the routine evaluation. Blood tests and additional imaging procedures will be done according to clinical indication. Lung Doppler signals will be recorded from selected locations over the right chest wall, preferably in sitting or semi-reclining position (if patient's condition permits). The recordings will be repeated several times in the EMD to monitor the changes following treatment. In some cases, LDS recordings may also be repeated later in the EMD or other hospital wards when the patient recovers from the acute condition (usually towards the end of the hospital stay). The acquired Doppler data will be saved by PC for off-line processing and analysis using the special algorithms that have been developed for this purpose.

The medical charts of enrolled subjects will also be accessed to obtain study specific information. The information that will be collected includes (but is not limited to): date of birth, gender, height, weight, past medical history, medications, physical examination, ECG, blood tests, pulmonary function tests (including spirometry and lung volumes), chest X-ray/CT and Echocardiography results. The results of study tests and procedures will be disclosed to EchoSense Ltd.

Since the study is non-interventional, the TPD recordings will not be used to guide medical treatment decisions. TPD recordings will not interfere with administering optimal treatment to the patient, which is of first priority in all recruited subjects.

C. Study Device The lung Doppler signals will be acquired by the Sonara/tek Transcranial Doppler (TCD) system. This commercially available TCD system was approved by the Federal Drug Administration on November 3rd, 2006 as a 510k class II device. This device was approved as a means of measuring blood flow velocities within the brain as well as peripheral blood vessels. We will utilize this non-invasive Doppler system in an investigational manner to record the lung Doppler signals. The recorded signals will later be analyzed by the EchoSense signal processing package.

Study Type

Observational

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Haifa, Israel
        • Rambam Medical Center

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients presenting to the EMD with acute cardiovascular and/or pulmonary conditions, including- but not restricted to- pneumonia, pulmonary embolism, CHF exacerbation, COPD exacerbation, shock, etc.

Description

Inclusion Criteria:

Men or women aged over 18. Suspected or confirmed acute cardiovascular or pulmonary condition.

Exclusion Criteria:

Minor (aged < 18). People unwilling to give informed consent. Pregnant women.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Time Frame
Diagnose irregular pattern of lung Doppler signals recorded in patients by features as velocity, power ect in comparison to control pattern
Time Frame: 1.5y to collect all data required to obtain a diagnostic pattern
1.5y to collect all data required to obtain a diagnostic pattern

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Shlomo Israelit, MD, Rambam Health Care Campus

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

November 1, 2014

Primary Completion (Actual)

April 1, 2015

Study Completion (Actual)

June 1, 2015

Study Registration Dates

First Submitted

October 6, 2013

First Submitted That Met QC Criteria

October 9, 2013

First Posted (Estimate)

October 11, 2013

Study Record Updates

Last Update Posted (Estimate)

August 13, 2015

Last Update Submitted That Met QC Criteria

August 12, 2015

Last Verified

May 1, 2013

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.