- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT06571968
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible
Accuracy of Computer Guided Four Implants Placement in Completely Edentulous Mandible by Using Fully Versus Semi Guided Prototyped Surgical Stent
Study Overview
Status
Conditions
Intervention / Treatment
Detailed Description
Objectives: Current study aimed to assess the accuracy of fully- guided implant placement in completely lower edentulous patients compared to the semi-guided protocol.
Materials and Methods: Thirty-six completely edentulous healthy patients received four mandibular implants and were randomly divided into the following groups: (A) The implants were installed by fully guided stereolithographic stent (n = 18), and (B) The implants were installed by semi-guided stereolithographic stent. (n = 18). The accuracy analysis was performed by one experienced process engineer (DB). Cone beam computed tomography was performed before and after the surgical procedure to plan the virtual implant position and fabricate the surgical guide, as well as to determine implant position deviations. Both CBCT scans were superimposed, and the software compared preoperative linear and angular virtual measurements of planned implants with real measurements of the placed implants. Measurements and analysis of results were performed by means of a software tool used during virtual planning (P3Dental; Protótipos).
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Mansoura, Egypt
- Marwa Aboelez
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
inclusion criteria:
- All patient wearing maxillary conventional denture.
- All patients had temporary mandibular overdenture supported by vertically inserted 4-implant at least six months ago.
- They were healthy, free from any systemic diseases relating to bone resorption such as uncontrolled diabetics or osteoporosis. This was achieved through medical history and clinical examination by physician.
- All patients are of angel's class I maxillo-mandibular relationships.
Exclusion Criteria:
- Patients had head and neck radiotherapy, patients with bleeding disorders or hepatic patients.
- Patients with metabolic disorders as diabetes mellitus, osteoporosis and hepatic disorders that might affect osseointegration.
- Long term immunosuppress and corticosteroid drug therapy.
- Patient with abnormal habits as clenching and bruxism.
- Smoking patient.
- Patient with problems in TMJ
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Other: fully guided surgical technique
The guides were designed with metal sleeves for guided drilling and guided implant placement and additional guide sleeves for the stabilization of the template by fixation screws.The implant width and length were selected for each patient according to previous 3d cone beam, and the drills of this kit were 11 mm longer than conventional drills.
The surgery was performed without flap elevation.
The guide was seated and fixed by means of 2-mm cortical screws in the buccal region after using of the corresponding drills.
|
All surgical procedures with drills were done through the stent., the implant was picked up from the implant holder and then installed, still with the surgical guide in situ, by using the ratchet and ratchet connector at a motor speed of 20 rpm, followed by cover screw placement without the need for sutures.
|
|
Other: semi guided surgical technique
The guides were designed with metal sleeves for guided drilling and guided implant placement and additional guide sleeves for the stabilization of the template by fixation screws.The implant width and length were selected for each patient according to previous 3d cone beam, and the drills of this kit were 11 mm longer than conventional drills.The surgery was performed without flap elevation.
The stent was removed before the final drilling
|
The first osteotomy was performed with the surgical guide in situ using a 1.95 mm pilot-drill. Successive color coded implant drills were used to prepare implant osteotomies. When using each twist drill, a removable sleeve having a diameter to coincide with the drill and inserted into the sleeve of the surgical guide. The stereo lithographic guide template was removed and the receptor sites were irrigated with saline solution then the final drill of the implant system 3.5 mm diameter was used to finalize the osteotomy. The implant was gripped with the placement aid, released from the implant holder by 1/4 turn and manually inserted into the prepared implant site using a finger placement tool or hand ratchet. A torque of 45 N cm should not be exceeded during insertion procedure and cover screws were screwed over it. |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Radio graphic evaluation (Angular deviation)
Time Frame: one year
|
For both groups, postoperative CBCT scan was performed after implant placement.
The same parameters of preoperative CBCT were followed according to the patient's position, image acquisition, and use of the same apparatus.
This scan was performed with the same dental prosthesis as that used for the initial preoperative CBCT scanning, equipped with the gutta percha references, for superimposition of the images.
The previously fabricated occlusal registration was used to align the prosthesis.
Both CBCT scans were superimposed, and the software compared preoperative horizontal (Mesiodistal and buccolingual), vertical and angular virtual measurements of planned implants with real measurements of the placed implants.
|
one year
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Radio graphic evaluation (linear deviation)
Time Frame: one year
|
For both groups, postoperative CBCT scan was performed after implant placement.
The same parameters of preoperative CBCT were followed according to the patient's position, image acquisition, and use of the same apparatus.
This scan was performed with the same dental prosthesis as that used for the initial preoperative CBCT scanning, equipped with the gutta percha references, for superimposition of the images.
The previously fabricated occlusal registration was used to align the prosthesis.
Both CBCT scans were superimposed, and the software compared preoperative horizontal (Mesiodistal and buccolingual) measurements of planned implants with real measurements of the placed implants.
|
one year
|
Collaborators and Investigators
Sponsor
Investigators
- Study Chair: marwa aboelez, Phd, Mansoura University
- Study Director: Hassan Kheriba, Msd, Mansoura University
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- M05010322
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Access Criteria
IPD Sharing Supporting Information Type
- SAP
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.