Effectiveness of a Zinc Oxide Adhesive Securement Device in the Fixation of Midline and Peripherally Inserted Central Catheters in Hospitalized Adult Patients (FIX-ETI)

September 17, 2026 updated by: Ferran Padilla Nula, Hospital Arnau de Vilanova

Effectiveness of a Zinc Oxide Adhesive Securement Device in the Fixation of Midline and Peripherally Inserted Central Catheters in Hospitalized Adult Patients: Randomised Clinical Trial

Study in which a zinc oxide fixation device (a product that can help protect the skin) for catheters (polyurethane tubes inserted into a vein) will be tested to reduce catheter-related complications: catheter displacement, skin complications, phlebitis and pain..

Study Overview

Detailed Description

Introduction: Midline catheters (MLC) and peripherally inserted central catheters (PICC) are commonly used vascular access devices (VAD) in healthcare institutions where infusion therapies are required, and have been proven to have an optimal level of safety and efficacy for intravenous drug delivery. However, the insertion of these VADs has a number of potential associated complications (immediate, early and/or late), and proper fixation may reduce them.

Hypothesis: Using a zinc oxide adhesive securement device (ASD) reduces the number of fixation-associated complications in MLC and PICC compared to a universal ASD with silicone adhesive.

Objective: To evaluate the efficacy of using a ASD with zinc oxide for post insertion fixation of MLC and PICC in hospitalised adult patients.

Methodology: Randomised clinical study. Two randomised groups will be created before catheter cannulation. The control group will be cured with an ASD with acrylic adhesive (Grip-Lok® Ref.3300MWA) and the intervention group will be cured with ASD with zinc oxide (Grip-Lok® Ref.2200NUZA).

Expected results: The investigators expect to reduce the number of complications related to the attachment of PICCs and MLCs in adult hospitalised patients following the protocolised placement of a ASD with zinc oxide during the first cure. Specifically, it is expected to reduce the number of catheter dislodgements, the number of medical adhesive-related skin injuries (MARSI) and the amount of phlebitis.

Clinical implication: The study will help to improve decision making related to maintenance and care of VAD in order to reduce the main associated complications.

Study Type

Interventional

Enrollment (Actual)

400

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Catalonia
      • Lleida, Catalonia, Spain, 25198
        • Hospital Universitari Arnau de Vilanova
      • Lleida, Catalonia, Spain, 25001
        • Arnau de Vilanova Hospital

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • requiring cannulation of a midline catheter or a PICC
  • who accepted and signed the informed consent voluntarily
  • with an inpatient unit admission of minimum 7 days

Exclusion Criteria:

- patients with a known allergy to zinc oxide

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Prevention
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: Double

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Active Comparator: Control

After cannulation of a midline or peripherally inserted central venous catheter with modified micro-Seldinger technique, the control group underwent standard care.

The standard care consists of:

  • Application of hemostasis at the point of insertion for 2 minutes post puncture or until bleeding stops.
  • Fix with clear polyurethane dressing (3M®-1655 Tegaderm™ IV), cyanoacrylate glue (SecurePortIV®) and acrylic adhesive sutureless fixation device (3300MWA Grip-Lok®).
Other Names:
  • Control

The PICC lines used in the study will all be third-generation polyurethane and of the commercial brands:

  • PowerPICC™ 4, 5 and 6 Fr from BD
  • Maxflo expert™ 5 and 6 Fr from Vygon

The midline lines used in the study will be second or third generation polyurethane and of the commercial brands:

  • PowerMidline™ 4 Fr from BD
  • Arrow® Midline 4Fr from Arrow

All punctures will be performed under ultrasound guidance.

Other Names:
  • Ultrasound
Experimental: Intervention

After cannulation of a midline or peripherally inserted central venous catheter with modified micro-Seldinger technique, the intervention group underwent the alternative care.

The PICC lines used in the study will all be third-generation polyurethane and of the commercial brands:

  • PowerPICC™ 4, 5 and 6 Fr from BD
  • Maxflo expert™ 5 and 6 Fr from Vygon

The midline lines used in the study will be second or third generation polyurethane and of the commercial brands:

  • PowerMidline™ 4 Fr from BD
  • Arrow® Midline 4Fr from Arrow

All punctures will be performed under ultrasound guidance.

Other Names:
  • Ultrasound

Alternative care consisted of:

  • Application of haemostasis at the insertion site for 2 minutes post-puncture or until cessation of bleeding.
  • Fixation with clear polyurethane dressing (3M®-1655 Tegaderm™ IV), cyanoacrylate glue (SecurePortIV®) and zinc oxide sutureless fixation device (2200NUZA Grip-Lok®).
Other Names:
  • Intervention

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of participants with treatment-related adverse events as assessed by CTCAE v5.0.
Time Frame: 7 days

Percentage of participants with adverse events following cannulation of a midline or peripherally inserted central catheter after fixation with a zinc oxide sutureless fixation device.

7 days

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of participants with altered skin under the sutureless fixation device assessed by observation (yes/no).
Time Frame: 7 days

Percentage of participants with skin alterations under the sutureless fixation device after puncture of a midline or central venous catheter with the modified micro-Seldinger technique. Four examinations will be performed: post puncture, at 24 hours, at 72 hours and at 7 days, in which the puncture site will be visualized for signs of skin alterations and it will be noted whether they exist and what type (Hematoma, Skin Stripping, Tension Injury or Blister, Skin Tear, Irritant Contact Dermatitis, Allergic Contact Dermatitis, Maceration or Folliculitis).

7 days
Number of participants with post-treatment catheter displacement assessed by observation (yes/no).
Time Frame: 7 days

Percentage of participants with catheter displacement after puncture of a midline or central venous catheter with the modified micro-Seldinger technique. Four cures will be performed: post puncture, at 24 hours, 72 hours and 7 days, where the puncture site will be visualized to check if the catheter is still in the same point or if it has been displaced.

7 days
Number of participants with post-treatment phlebitis assessed with the Maddox visual phlebitis rating scale.
Time Frame: 7 days

Percentage of participants with phlebitis after puncture of a midline or central venous catheter with the modified micro-Seldinger technique. Four cures will be performed: post puncture, at 24 hours, 72 hours and 7 days, where the puncture site will be visualized to check for signs of phlebitis, according to the Maddox scale.

7 days
Number of participants with post-treatment pain in extremity assessed with the EVA scale.
Time Frame: 7 days

Percentage of participants with pain in extremity after puncture of a midline or central venous catheter with the modified micro-Seldinger technique. Four cures will be performed: post puncture, at 24 hours, 72 hours and 7 days, where the patient will be asked what pain he/she feels in the extremity related to the catheter.

7 days

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

February 1, 2025

Primary Completion (Actual)

July 31, 2026

Study Completion (Actual)

September 15, 2026

Study Registration Dates

First Submitted

December 24, 2024

First Submitted That Met QC Criteria

January 7, 2025

First Posted (Actual)

January 13, 2025

Study Record Updates

Last Update Posted (Actual)

September 18, 2026

Last Update Submitted That Met QC Criteria

September 17, 2026

Last Verified

April 1, 2026

More Information

Terms related to this study

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

YES

IPD Plan Description

The data from the FIX-ETI project were uploaded to Mendelay data, so that the data can be observed and analyzed by the entire scientific community and anyone interested in the subject.

The research protocol, the informed consent, the infographic presented to the patients, the data collection notebook and the data collected during all the cures will be uploaded and retrieved from the REDCap database.

IPD Sharing Time Frame

Open

IPD Sharing Access Criteria

Will be accessible to everyone through the Mendelay data platform.

IPD Sharing Supporting Information Type

  • STUDY_PROTOCOL
  • ICF

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe