A Study Comparing Two Mandibular Advancement Devices in the Treatment of Sleep Apnea (MRA OSA)

August 6, 2026 updated by: Ziekenhuis Oost-Limburg

A Randomised, Controlled Cross Over Study Comparing Two Mandibular Advancement Devices in the Treatment of Mild-to-moderate Obstructive Sleep Apnea

The goal of this randomised, controlled cross-over study is to compare two mandibular repositioning devices (MRA) already on the market in the treatment of mild-to-moderate obstructive sleep apnea.

Patiënt will test the first MRA for 3 months, after a wash out period of 2 weeks they will test the second MRA for 3 months. It will be randomised what type of MRA will be tested first and second.

Study Overview

Detailed Description

A mandibular repositioning appliance (MRA) is the primary treatment option for patients with mild to moderate obstructive sleep apnea (OSA), as well as for those with severe OSA who are intolerant to continuous positive airway pressure (CPAP) therapy or for whom surgical interventions are not viable. MRAs function by advancing the mandible, thereby increasing the volume of the upper airway and reducing its tendency to collapse during sleep. Various types of MRAs are available, and multiple classification systems can be employed to distinguish between these different types.

Mandibular repositioning appliances (MRAs) can be either custom-made or universal. Custom-made devices, which are typically more expensive, are fabricated in a dental laboratory using dental impressions. In contrast, prefabricated devices, often thermoplastic MRAs, are generally less costly and readily available over the counter.

Mandibular repositioning appliances (MRAs) can be classified as non-titratable, also known as monoblock devices, which have a fixed position, or titratable devices, which allow for gradual adjustment of the mandibular position until the desired therapeutic effect is achieved. Current guidelines recommend the use of titratable MRAs.

Titratable mandibular repositioning appliances (MRAs) can be further categorized into two types: midline traction devices, where the upper and lower components are connected at the front of the device, and bilateral thrust devices, where the upper and lower components are linked in the lateral or (pre-)molar regions.

Within the latter category, various designs exist, including devices that are adjustable on both sides using Hyrax screws and 3D-printed devices equipped with a series of lower components that allow for adjustments in mandibular position.

An example of an MRA adjustable with Hyrax screws is the SomnoDent® device (SomnoMed, Denton, Texas, USA). An example of a device utilizing a series of lower components for titration is the OrthoApnea appliance (ORTHOAPNEA S.L., Málaga, Spain), which features a specific attachment mechanism.

Although studies have already been published comparing different types of "bilateral thrust" devices, no studies to date have directly compared the categories mentioned above. The hypothesis of the investigators is that both appliances have similar effectiveness in the treatment of mild-to-moderate obstructive sleep apnea.

Primary objective:

Improvement of AHI, measured by polygraphy before treatment and after treatment with each MRA.

Secondary objective;

  • Peripheral oxygen saturation, measured by polygraphy before treatment and after treatment with each MRA

    • Average saturation
    • Lowest saturation
    • Oxygen desaturation index >3% (events/h)
    • Total duration with saturation < 90%
  • Epworth Sleepiness Scale, taken before treatment and after treatment with each MRA
  • Patient experience questionnaire, taken before treatment and after treatment with each MRA
  • Patient final choice of preferred MRA

Endpoints:

The investigators assess the objective improvement in OSA by comparing polygraphy results taken before and after treatment with each MRA. To evaluate the subjective effects of the MRA, the investigators compare the scores from the Epworth Sleepiness Scale. The participants subjective experience with each MRA type is measured using a patient experience questionnaire, along with noting the final preference for device type of the participants.

Study design:

  • Randomized, controlled cross-over study
  • Study population: Patients referred to the Department of Oral and Maxillofacial Surgery at ZOL Genk for Mandibular Repositioning Appliance (MRA) therapy, aged 18 years or older diagnosed with an Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour.

Inclusion criteria:

In order to be eligible to participate in this study, a subject must meet all of the following criteria:

  • Provide signed and dated informed consent
  • Males or females aged 18 and above
  • Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour diagnosed by a polysomnography

Exclusion criteria:

A potential subject who meets any of the following criteria will be excluded from participation in this study:

  • Previous surgery on the upper airways
  • Prior treatment of OSA (CPAP or MRA)
  • Presence of unstable cardiovascular conditions, neurological, mental, or psychiatric disorders
  • Insufficient dental or periodontal condition for a mandibular repositioning appliance (MRA)
  • Presence of temporomandibular joint dysfunction

Study Type

Interventional

Enrollment (Actual)

16

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Genk, Belgium, 3600
        • Ziekenhuis Oost-Limburg

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

  • Adult
  • Older Adult

Accepts Healthy Volunteers

No

Description

In order to be eligible to participate in this study, a subject must meet all of the following criteria:

  • Provide signed and dated informed consent
  • Males or females aged 18 and above
  • Apnea-Hypopnea Index (AHI) between 5 and 30 events per hour diagnosed by a polysomnography

A potential subject who meets any of the following criteria will be excluded from participation in this study:

  • Previous surgery on the upper airways
  • Prior treatment of OSA (CPAP or MRA)
  • Presence of unstable cardiovascular conditions, neurological, mental, or psychiatric disorders
  • Insufficient dental or periodontal condition for a mandibular repositioning appliance (MRA)
  • Presence of temporomandibular joint dysfunction

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Crossover Assignment
  • Masking: Single

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: MRA1MRA2
Use of MRA device 1 for 3 months, use of MRA device 2 for 3 months

Epworth Sleepiness Scale

o Johns, Murray W. "A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale." Sleep, vol. 14, no. 6, 1991, pp. 540-545.

Patient experience questionnaire

o Ng, E.T., Perez-Garcia, A., en Lagravère-Vich, M.O. "Development and Initial Validation of a Questionnaire to Measure Patient Experience with Oral Appliance Therapy." Journal of Clinical Sleep Medicine, vol. 19, nr. 8, 1 aug. 2023, pp. 1437-1445. doi: 10.5664/jcsm.10562. PMID: 37082817; PMCID: PMC10394373

Patient final choice of preferred MRA
Polygraphy after 3 months of use of each appliance: an unattended home sleep study at the end of the first treatment period, and in-hospital polygraphy at the end of the second treatment period.
Experimental: MRA2MRA1
Use of MRA device 2 for 3 months, use of MRA device 1 for 3 months

Epworth Sleepiness Scale

o Johns, Murray W. "A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness Scale." Sleep, vol. 14, no. 6, 1991, pp. 540-545.

Patient experience questionnaire

o Ng, E.T., Perez-Garcia, A., en Lagravère-Vich, M.O. "Development and Initial Validation of a Questionnaire to Measure Patient Experience with Oral Appliance Therapy." Journal of Clinical Sleep Medicine, vol. 19, nr. 8, 1 aug. 2023, pp. 1437-1445. doi: 10.5664/jcsm.10562. PMID: 37082817; PMCID: PMC10394373

Patient final choice of preferred MRA
Polygraphy after 3 months of use of each appliance: an unattended home sleep study at the end of the first treatment period, and in-hospital polygraphy at the end of the second treatment period.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
AHI
Time Frame: 3 monthts after use of first MRA (mandibular advancement device), 3 months after use of second MRA (mandibular advancement device)
Improvement of AHI (apnea-hypopnea index), measured by polygraphy before treatment and after treatment with each MRA. The goal of the mandibular advancement device is to reduce the number of apneas and hypopneas per hour, apneas are periods when a person stops breathing and hypopneas are instances where airflow is blocked, causing shallow breathing. This is measured by a polygraphy-test overnight at the patiënts home.
3 monthts after use of first MRA (mandibular advancement device), 3 months after use of second MRA (mandibular advancement device)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Peripheral oxygen saturation 1
Time Frame: 3 monthts after use of first MRA, 3 months after use of second MRA

Measured by polygraphy

  • Average saturation (measured in %)
  • Lowest saturation (measured in %)

Oxygen saturation in percent is the fraction of oxygen-saturated haemoglobin relative to total haemoglobin (unsaturated + saturated) in the blood * 100%

3 monthts after use of first MRA, 3 months after use of second MRA
Peripheral oxygen saturation 2
Time Frame: 3 monthts after use of first MRA, 3 months after use of second MRA

Measured by polygraphy

o Oxygen desaturation index >3% (events/h)

Desaturation episodes are defined as a decrease in the mean oxygen saturation of ≥3% for more than 10 seconds per hour

3 monthts after use of first MRA, 3 months after use of second MRA
Peripheral oxygen saturation 3
Time Frame: 3 monthts after use of first MRA, 3 months after use of second MRA

Measured by polygraphy

o Total duration with saturation < 90%

The percentage of cumulative time with oxygen saturation below 90% in total sleep time.

3 monthts after use of first MRA, 3 months after use of second MRA
ESS
Time Frame: 3 monthts after use of first MRA, 3 months after use of second MRA

Epworth Sleepiness Scale (questionaire)

The minimum value is 0 and the maximum value is 24. A higher score means a worse outcome, indicating more excessive daytime sleepiness.

The Epworth Sleepiness Scale is scored by adding up the individual scores for each of the eight questions. Each question is rated on a scale of 0 to 3, with 0 being "no chance of dozing" and 3 being "high chance of dozing." ter daytime sleepiness.

Score range Interpretation 0-5 Lower normal daytime sleepiness 6-10 Normal daytime sleepiness 11-12 Mild excessive daytime sleepiness 13-15 Moderate excessive daytime sleepiness 16-24 Severe excessive daytime sleepiness

3 monthts after use of first MRA, 3 months after use of second MRA
Final choice
Time Frame: after the use of each MRA for 3 months

Patient final choice of preferred MRA.

At the final visit, after using each MRA (type 1 and type 2) for three months (with a two-week washout period in between), the patient will choose their preferred device. The final choice will be noted down after oral questioning.

after the use of each MRA for 3 months
Patient experience questionnaire
Time Frame: 3 months after use of the first MRA, 3 months after use of the second MRA
Patient experience with each appliance, assessed after 3 months of use. The appliance-design domain of the Oral Appliance Therapy Patient Experience Questionnaire (OATPEQ; Ng et al., J Clin Sleep Med 2023) was used, translated into Dutch. It comprises 13 statements, each scored from 0 to 4, giving a total score ranging from 0 to 52. A higher score indicates a more positive patient experience.
3 months after use of the first MRA, 3 months after use of the second MRA

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Publications and helpful links

The person responsible for entering information about the study voluntarily provides these publications. These may be about anything related to the study.

General Publications

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

March 21, 2025

Primary Completion (Actual)

March 6, 2026

Study Completion (Actual)

March 6, 2026

Study Registration Dates

First Submitted

January 24, 2025

First Submitted That Met QC Criteria

January 30, 2025

First Posted (Actual)

February 5, 2025

Study Record Updates

Last Update Posted (Actual)

August 11, 2026

Last Update Submitted That Met QC Criteria

August 6, 2026

Last Verified

August 1, 2026

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.

Subscribe