- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07453810
Flow- Versus Volume-controlled Ventilation During Robot-assisted Laparoscopic Radical Prostatectomy
March 21, 2026 updated by: Gokcen Kulturoglu, Ankara Etlik City Hospital
During robot-assisted laparoscopic radical prostatectomy (RALRP), patients are placed under general anesthesia and supported with mechanical ventilation.
In this study, the effects of two different ventilatory strategies-flow-controlled ventilation (FCV) and volume-controlled ventilation (VCV)-were compared.
Using electrical impedance tomography (EIT) to provide real-time assessment of lung status and to guide individualized positive end-expiratory pressure (PEEP) settings, we investigated whether FCV offers superior oxygenation and improved respiratory system mechanics compared with VCV.
Study Overview
Status
Completed
Conditions
Intervention / Treatment
Study Type
Interventional
Enrollment (Actual)
50
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
Ankara
-
Ankara, Ankara, Turkey (Türkiye), 06170
- Etlik City Hospital
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Yes
Description
Inclusion Criteria:
- Male patients aged 18 years or older
- American Society of Anesthesiologists physical status (ASA-PS) class I-III
- Scheduled for robot-assisted laparoscopic radical prostatectomy (RALRP)
- Provided written informed consent to participate in the study
Exclusion Criteria:
- Patients who declined to participate or withdrew consent
- Conversion from robot-assisted laparoscopic radical prostatectomy to open surgery
- Reoperation within 7 days postoperatively
- Chronic pulmonary disease
- Implanted cardiac devices
- Congestive heart failure New York Heart Association III/IV
- Severe haemodynamic instability after induction of anaesthesia
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Triple
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Flow-controlled ventilation (FCV)
Patients received intraoperative mechanical ventilation using flow-controlled ventilation during robot-assisted laparoscopic radical prostatectomy.
Positive end-expiratory pressure (PEEP) was individualized using electrical impedance tomography (EIT) following a standardized titration protocol.
|
Mechanical ventilation delivered in a flow-controlled mode with constant inspiratory and expiratory flow patterns
|
|
Active Comparator: Volume-controlled ventilation (VCV)
Patients received intraoperative mechanical ventilation using volume-controlled ventilation during robot-assisted laparoscopic radical prostatectomy.
Positive end-expiratory pressure (PEEP) was individualized using electrical impedance tomography (EIT) following the same standardized titration protocol.
|
Mechanical ventilation delivered in a volume-controlled mode with constant tidal volume and decelerating inspiratory flow pattern.
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The ratio of arterial oxygen partial pressure to fractional inspired oxygen (PaO2/FiO2)
Time Frame: During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
The primary outcome is the PaO2/FiO2 before extubation (T4).
|
During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Driving pressure
Time Frame: During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
Driving pressure is measured as the difference between plateau pressure and positive end-expiratory pressure (PEEP), with values obtained directly from the ventilator display in the VCV group.
In the FCV group, tracheal driving pressure is recorded from the ventilator and corrected for endotracheal tube resistance to calculate alveolar driving pressure, allowing physiologically comparable measurements between groups.
|
During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
|
Mechanical power
Time Frame: During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
Mechanical power (MP) is calculated from recorded ventilatory parameters.
In the volume-controlled ventilation (VCV) group, MP is calculated using respiratory rate, tidal volume, peak airway pressure, and driving pressure.
In the flow-controlled ventilation (FCV) group, MP is calculated using minute ventilation, peak pressure, PEEP, and inspiratory flow.
|
During the intraoperative period at four predefined time points: after induction of general anesthesia (T1), after pneumoperitoneum and Trendelenburg positioning (T2), 60 minutes after T2 (T3), and before extubation (T4).
|
|
Lung ultrasound score
Time Frame: Lung ultrasound scores (LUS) are assessed at two time points: immediately before anesthesia induction and on the first postoperative day.
|
Lung ultrasound (LUS) examination is performed with the patient in the supine position using an ultrasound device equipped with a low-frequency (2.5-5 MHz) convex probe suitable for intercostal imaging.
The thoracic surface is systematically evaluated in both longitudinal and transverse planes.
For standardized assessment, each hemithorax is divided into anterior, lateral, and posterior regions, and each region is further subdivided into upper and lower areas, resulting in a total of 12 scanning zones.
Normal aeration, defined as the presence of A-lines or fewer than two isolated B-lines with preserved lung sliding, is scored as 0. The presence of three or more well-spaced B-lines with preserved sliding is scored as 1.
Coalescent B-lines indicating moderate loss of aeration are scored as 2. Pulmonary consolidation is scored as 3.
The total LUS score ranges from 0 to 36, with higher scores indicating greater loss of lung aeration.
|
Lung ultrasound scores (LUS) are assessed at two time points: immediately before anesthesia induction and on the first postoperative day.
|
|
pulmonary/extrapulmonary complications
Time Frame: The first seven postoperative days
|
The first seven postoperative days
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Actual)
November 28, 2025
Primary Completion (Actual)
March 13, 2026
Study Completion (Actual)
March 20, 2026
Study Registration Dates
First Submitted
February 23, 2026
First Submitted That Met QC Criteria
February 27, 2026
First Posted (Actual)
March 6, 2026
Study Record Updates
Last Update Posted (Actual)
March 25, 2026
Last Update Submitted That Met QC Criteria
March 21, 2026
Last Verified
March 1, 2026
More Information
Terms related to this study
Other Study ID Numbers
- AEŞH-EK-2025-257
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
NO
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
No
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.