- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07737197
Single _ Drill Vs Full Sequence Guided Implant Placement
July 30, 2026 updated by: Ahmed Alnoor Ahmed Mohammed, Cairo University
Accuracy of Single Drill Versus Full Sequence Computer Guidance in Dental Implant Placement
This randomized clinical trial aims to compare the accuracy of single-drill (pilot-guided) computer-guided implant surgery versus full-sequence computer-guided dental implant placement.
The study evaluates clinical and radiographic outcomes, focusing on apical, angular, coronal, and depth linear deviations using post-operative cone-beam computed tomography (CBCT) superimposition.
Study Overview
Status
Completed
Conditions
Study Type
Interventional
Enrollment (Actual)
16
Phase
- Not Applicable
Contacts and Locations
This section provides the contact details for those conducting the study, and information on where this study is being conducted.
Study Locations
-
-
-
Cairo, Egypt
- Faculty of Dentistry, Cairo University
-
-
Participation Criteria
Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
No
Description
Inclusion Criteria:
- Age >= 18 years, both sexes
- Patients requiring dental implant placement in the posterior region (molar area)
- Patients systemically healthy with no medical history contraindicating implant surgery
- Sufficient inter-arch space for future prosthesis (minimum 7 mm)
Exclusion Criteria:
- Bone height < 6 mm at the proposed implant site
- Inadequate oral hygiene
- Heavy smoking (>10 cigarettes/day)
- Alcohol or drug abuse
- Pregnancy
- Local or systemic infection
- Uncontrolled metabolic disease (e.g., diabetes mellitus)
- Severe hepatic or renal dysfunction
- Chemotherapy or radiotherapy within the last 5 years
- Immunosuppression therapy or autoimmune disorders
- Complete edentulism
- Pathological conditions such as periapical or periodontal abscesses
- Untreated gingivitis or periodontitis
Study Plan
This section provides details of the study plan, including how the study is designed and what the study is measuring.
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Full Sequence Computer Guidance
Patients undergo dental implant placement using full-sequence computer guidance, where implant site preparation and insertion are accomplished using all sequential drills and metal reducers with the surgical guide.
|
Dental implant placement using full sequence computer guidance with all sequential drills and metal reducers
|
|
Active Comparator: Single Drill / Pilot-Guided Computer Guidance
Patients undergo dental implant placement using first-drill (pilot-guided) computer guidance, where the initial pilot osteotomy is performed through the surgical guide, followed by removal of the guide and completion of the remaining sequential drilling and implant placement freehand.
|
Dental implant placement using first-drill (pilot-guided) computer guidance, followed by freehand sequential drilling and placement
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Apical deviation
Time Frame: Immediately after surgery (Post-operative CBCT).
|
The linear deviation between the planned and actual implant apex position measured on post-operative CBCT superimposition.
|
Immediately after surgery (Post-operative CBCT).
|
Collaborators and Investigators
This is where you will find people and organizations involved with this study.
Sponsor
Study record dates
These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.
Study Major Dates
Study Start (Actual)
September 10, 2025
Primary Completion (Actual)
July 10, 2026
Study Completion (Actual)
July 10, 2026
Study Registration Dates
First Submitted
July 27, 2026
First Submitted That Met QC Criteria
July 27, 2026
First Posted (Actual)
July 30, 2026
Study Record Updates
Last Update Posted (Actual)
July 31, 2026
Last Update Submitted That Met QC Criteria
July 30, 2026
Last Verified
July 1, 2026
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- Guided-Implant-RCT-2026
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
No
Studies a U.S. FDA-regulated device product
No
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.