Automated Pupillometry for Diabetic Retinopathy Screening

November 16, 2026 updated by: Abraham Gajardo Cortez, University of Chile

Validation of Automatic Pupillometry for Diabetic Retinopathy Screening in Primary Health Care

The goal of this observational study is to learn if automated pupillometry (AP)-a simple tool that measures how the eye responds to a brief light stimulus-can help diagnose diabetic retinopathy (DR), a complication of diabetes that can lead to blindness, in people with type 2 diabetes (T2DM).

The main question it aims to answer is:

• How accurate is AP for screening DR in people with T2DM?

DR usually has no symptoms in its early stages, so early screening is crucial to prevent progression to blindness. Participants in this study will undergo two tests:

  • AP, which measures the eye's response to light.
  • A fundoscopic examination (FE), which is the current test used to diagnose DR. FE is performed by an ophthalmologist, making it more expensive and harder to access due to long waiting lists. These challenges mean not all people with diabetes can have this test annually, as recommended. AP could offer a cheaper and more accessible option that doesn't require a specialist, potentially reducing waiting times and enabling earlier diagnosis of DR in people with diabetes.

Study Overview

Detailed Description

Patients will undergo a clinical evaluation, AP assessment, and FE during the same visit. AP will be performed to obtain three valid trials per eye using a clinical pupilometer. For DR diagnosis, pupil-dilated eye fundus images will be captured with a retinal camera and subsequently interpreted by an ophthalmologist. Both patients and AP/FE operators will remain blinded to the FE/AP data.

Study Type

Observational

Enrollment (Actual)

240

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Santiago, Chile
        • Primary Care Ophthalmology Unit

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

30 years to 75 years (Adult, Older Adult)

Accepts Healthy Volunteers

N/A

Genders Eligible for Study

All

Sampling Method

Non-Probability Sample

Study Population

Patients with type 2 diabetes (T2DM) from all three public primary care health centers in the municipality of Independencia (Santiago, Chile), who are on the waiting list for fundoscopic examination (FE) to screen for diabetic retinopathy (DR).

Description

Inclusion Criteria:

  • Adult between 30 and 75 years old.
  • Diagnosis of T2DM made by a doctor according to the criteria indicated in the Explicit Health Guarantee Guide (GES) for T2DM (based on fasting blood glucose, oral glucose tolerance test or random blood glucose test in symptomatic subjects).
  • Native or conversational proficiency in Spanish.
  • Be under control in the Cardiovascular Health Program (PSCV) with at least two consultations registered since admission, or have entered the PSCV in the last six months.
  • Have a landline or mobile phone available to be contacted.

Exclusion Criteria:

  • Hospitalization and/or any recent acute illness (less than one month) that required medical attention.
  • History of any of the following diseases: non-diabetic retinopathy, blindness, deafness, oncological disease not cured or under active treatment, neurodegenerative disease, advanced cirrhosis (Child-Pugh B or C), uncompensated heart failure, acute stress disorder.
  • Ingestion of alcohol or recreational drugs within 8 hours prior to the Automated Pupillometry (AP) exam.
  • Dependency in basic activities of daily living.
  • Pregnancy.
  • Afro-American ancestry (greater activation of sympathetic tone in this population, which modifies pupillary reactivity).

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: OTHER
  • Time Perspectives: CROSS_SECTIONAL

Cohorts and Interventions

Group / Cohort
With Diabetic Retinopathy

Patient with diabetic retinopathy diagnosed through fundoscopic examination

Without Diabetic Retinopathy

Patient without diabetic retinopathy on fundoscopic examination.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Diagnostic accuracy of automated pupillometry (AP) for diabetic retinopathy (DR) screening
Time Frame: At baseline (study enrollment)

The diagnostic accuracy of AP for DR will be evaluated by the area under the curve (AUC), sensitivity, specificity and predictive values.

At baseline (study enrollment)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Prevalence of diabetic retinopathy in the study sample
Time Frame: At baseline (study enrollment)

Frequency (%) of participants with diabetic retinopathy in the sample

At baseline (study enrollment)
Risk factors for diabetic retinopathy
Time Frame: At baseline (study enrollment)

Clinical factors statistically related with diabetic retinopathy presence

At baseline (study enrollment)

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

January 26, 2023

Primary Completion (Actual)

August 18, 2023

Study Completion (Actual)

January 31, 2024

Study Registration Dates

First Submitted

November 11, 2026

First Submitted That Met QC Criteria

November 16, 2026

First Posted (Actual)

November 18, 2026

Study Record Updates

Last Update Posted (Actual)

November 18, 2026

Last Update Submitted That Met QC Criteria

November 16, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.