- ICH GCP
- US Clinical Trials Registry
- Clinical Trial NCT07954986
Soft and Hard Tissue Changes in Correction of Class II Malocclusion Via Two Modalities of Fixed Functional Appliance
Assessment of Soft and Hard Tissue Changes in Correction of Class II Malocclusion Via Two Modalities of Fixed Functional Appliance: A Randomized Controlled Study
This study aimed to evaluate the hard and soft tissue changes in correction of class II via Mandibular Anterior Repositioning Appliance (MARA) and Carrière Motion.
Study Overview
Status
Intervention / Treatment
Detailed Description
Class II malocclusion was found to be the second most prevalent malocclusion in mixed and permanent dentitions. The most consistent etiological factor in class II malocclusion is mandibular deficiency.
Based on the growth status treatment, options for Class II correction commonly include use of functional/fixed functional appliances (FFA), headgear, camouflage by extractions of premolars, or surgical correction of the underlying skeletal discrepancy when growth has completed.
The Mandibular Anterior Repositioning Appliance (MARA) is one of several functional appliances used today to correct Class II malocclusions by repositioning the mandibular condyles forward and downward.
Carriere Motion appliance (CMA), was unveiled in 2004. By distalizing the entire maxillary buccal segment using class II elastics and mandibular anchors, CMA was designed to treat Class II molar relationship.
Study Type
Enrollment (Estimated)
Phase
- Not Applicable
Contacts and Locations
Study Contact
- Name: Doha N Almarzooq, B.Sc
- Phone Number: +966565670789
- Email: dhouhanabeel90@gmail.com
Study Locations
-
-
-
Cairo, Egypt, 11651
- Recruiting
- Al- Azhar University
-
Contact:
- Doha N Almarzooq, B.Sc
- Phone Number: +966565670789
- Email: dhouhanabeel90@gmail.com
-
Sub-Investigator:
- Samir A Ibrahim, MD
-
Sub-Investigator:
- Marwa H Abd El-Meneim, MD
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Adolescent Female patients diagnosed of class II division 1 aged 13-16.
- Bilateral Class II Angle malocclusion.
Exclusion Criteria:
- Posterior crossbite.
- Deep bite.
- Patients with syndromes.
- Previous treatments.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: Group I
Patients treated with Mandibular Anterior Repositioning Appliance (MARA) appliance. |
Patients treated with Mandibular Anterior Repositioning Appliance (MARA). |
|
Active Comparator: Group II
Patients treated with Carrière Motion with Essix appliance. |
Patients treated with Carrière Motion with Essix appliance. |
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in A point-Nasion-B point (ANB) Angle
Time Frame: 3 months post-procedure
|
The A point-Nasion-B point (ANB) angle, defined by points A, nasion, and B, was measured in degrees on lateral cephalograms derived from cone-beam computed tomography (CBCT) scans. |
3 months post-procedure
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in Sella-Nasion-A point (SNA) Angle
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline Sella-Nasion-A point (SNA) angle, measured in degrees on cone-beam computed tomography (CBCT) -derived lateral cephalograms. |
3 months post-procedure
|
|
Change in Sella-Nasion-B point (SNB) Angle
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline Sella-Nasion-B point (SNB) angle, measured in degrees on cone-beam computed tomography (CBCT) -derived lateral cephalograms. |
3 months post-procedure
|
|
Change in Anterior Facial Height
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline distance from nasion to menton (N-Me), measured in millimeters on cone-beam computed tomography (CBCT)-derived lateral cephalograms. |
3 months post-procedure
|
|
Change in Lower Anterior Facial Height
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline distance from the anterior nasal spine to menton (ANS-Me), measured in millimeters on cone-beam computed tomography (CBCT)-derived lateral cephalograms. |
3 months post-procedure
|
|
Change in Lower-to-Total Anterior Facial Height Ratio
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline ratio of A point-Nasion-B point (ANB)-Me to N-Me, multiplied by 100. Change was reported in percentage points. |
3 months post-procedure
|
|
Change in Overjet
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline horizontal distance between the maxillary and mandibular incisors, measured in millimeters on cone-beam computed tomography (CBCT)-derived lateral cephalograms. |
3 months post-procedure
|
|
Change in Nasolabial Angle
Time Frame: 3 months post-procedure
|
Post-treatment minus baseline angle between the columella and upper lip at subnasale, measured in degrees on cone-beam computed tomography (CBCT)-derived lateral cephalograms. |
3 months post-procedure
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Estimated)
Study Completion (Estimated)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- P-OR-24-10
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
The data will be available upon a reasonable request from the corresponding author after the end of study for one year.
IPD Sharing Time Frame
After the end of study for one year.
IPD Sharing Access Criteria
The data will be available upon a reasonable request from the corresponding author.
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.