Active Bone Conduction Prosthesis: Bonebridge(TM)
Mario E Zernotti, Andrea Bravo Sarasty, Mario E Zernotti, Andrea Bravo Sarasty
Abstract
Introduction Bone conduction implants are indicated for patients with conductive and mixed hearing loss, as well as for patients with single-sided deafness (SSD). The transcutaneous technology avoids several complications of the percutaneous bone conduction implants including skin reaction, skin growth over the abutment, and wound infection. The Bonebridge (MED-EL, Austria) prosthesis is a semi-implantable hearing system: the BCI (Bone Conduction Implant) is the implantable part that contains the Bone Conduction-Floating Mass Transducer (BC-FMT), which applies the vibrations directly to the bone; the external component is the audio processor Amadé BB (MED-EL, Austria), which digitally processes the sound and sends the information through the coil to the internal part. Bonebridge may be implanted through three different approaches: the transmastoid, the retrosigmoid, or the middle fossa approach. Objective This systematic review aims to describe the world́s first active bone conduction implant system, Bonebridge, as well as describe the surgical techniques in the three possible approaches, showing results from implant centers in the world in terms of functional gain, speech reception thresholds and word recognition scores. Data Synthesis The authors searched the MEDLINE database using the key term Bonebridge. They selected only five publications to include in this systematic review. The review analyzes 20 patients that received Bonebridge implants with different approaches and pathologies. Conclusion Bonebridge is a solution for patients with conductive/mixed hearing loss and SSD with different surgical approaches, depending on their anatomy. The system imparts fewer complications than percutaneous bone conduction implants and shows proven benefits in speech discrimination and functional gain.
Keywords: bone conduction hearing; bone conduction implants; bonebridge; conductive hearing loss; mixed hearing loss; single sided deafness.
Conflict of interest statement
Conflicts of Interest Andrea Bravo Sarasty is employed by the device manufacturer. The other authors declare no conflicts of interest.
Figures








References
- Güldner C, Heinrichs J, Weiß R. et al.Visualisation of the Bonebridge by means of CT and CBCT. Eur J Med Res. 2013;18(1):30.
- Sprinzl G, Lenarz T, Ernst A. et al.First European multicenter results with a new transcutaneous bone conduction hearing implant system: short-term safety and efficacy. Otol Neurotol. 2013;34(6):1076–1083.
- Barbara M, Perotti M, Gioia B, Volpini L, Monini S. Transcutaneous bone-conduction hearing device: audiological and surgical aspects in a first series of patients with mixed hearing loss. Acta Otolaryngol. 2013;133(10):1058–1064.
- Lassaletta L, Sanchez-Cuadrado I, Munoz E, Gavilan J. Retrosigmoid implantation of an active bone conduction stimulator in a patient with chronic otitis media. Auris Nasus Larynx. 2014;41(1):84–87.
- Canis M, Ihler F, Blum J, Matthias C. CT-assisted navigation for retrosigmoidal implantation of the Bonebridge. HNO. 2013;61(12):1038–1044.
- Tsang W S, Yu J K, Bhatia K S, Wong T K, Tong M C. The Bonebridge semi-implantable bone conduction hearing device: experience in an Asian patient. J Laryngol Otol. 2013;127(12):1214–1221.
- Clarós P Diouf M S Clarós A Setting up a “Bonebridge” Rev Laryngol Otol Rhinol (Bord) 20121334-5217–220. French
- Hassepass F, Bulla S, Aschendorff A. et al.The bonebridge as a transcutaneous bone conduction hearing system: preliminary surgical and audiological results in children and adolescents. Eur Arch Otorhinolaryngol. 2015;272(9):2235–2241.
- Siegert R. Combined reconstruction of congenital auricular atresia and severe microtia. Adv Otorhinolaryngol. 2010;68:95–107.
- Digoy G P, Cueva R A. Congenital aural atresia: review of short- and long-term surgical results. Otol Neurotol. 2007;28(1):54–60.
- Yellon R F. Combined atresiaplasty and tragal reconstruction for microtia and congenital aural atresia: thesis for the American Laryngological, Rhinological, and Otological Society. Laryngoscope. 2009;119(2):245–254.
- Ricci G, Della Volpe A, Faralli M. et al.Results and complications of the Baha system (bone-anchored hearing aid) Eur Arch Otorhinolaryngol. 2010;267(10):1539–1545.
- Hobson J C, Roper A J, Andrew R, Rothera M P, Hill P, Green K M. Complications of bone-anchored hearing aid implantation. J Laryngol Otol. 2010;124(2):132–136.
- Badran K, Arya A K, Bunstone D, Mackinnon N. Long-term complications of bone-anchored hearing aids: a 14-year experience. J Laryngol Otol. 2009;123(2):170–176.
Source: PubMed
Upcoming Clinical Trials
-
Septerna, Inc.Not yet recruitingHealthy Adult ParticipantsAustralia
-
Alperen KalyoncuRecruitingPostoperative Pain | Dental Anxiety | Impacted Tooth | Binaural BeatsTurkey (Türkiye)
-
Suleyman Demirel UniversityRecruitingSoccer PlayersTurkey (Türkiye)
-
Centre Hospitalier le MansNot yet recruitingProstatic Penetration of LinezolidFrance
-
BiogenNot yet recruiting
-
University of KerbalaNot yet recruiting
-
Evans Fernandez PerezJohns Hopkins University; National Heart, Lung, and Blood Institute (NHLBI); Genentech...Not yet recruitingObinutuzumab in Adults With Connective Tissue Disease-Associated Interstitial Lung Disease (OCTILIA)Connective Tissue Disease-associated Interstitial Lung DiseaseUnited States
-
Children's Hospital of PhiladelphiaEunice Kennedy Shriver National Institute of Child Health and Human Development... and other collaboratorsNot yet recruitingCare Coordination | Postpartum | Postpartum Anxiety | Postpartum Care | Postpartum Depression (PPD) | Care Gaps | Hypertension Disorders in PregnancyUnited States
-
Beijing Friendship HospitalNot yet recruiting
-
Milap SandhuRecruitingSpinal Cord Injuries (SCI) | Neurogenic Bladder DisorderUnited States
-
Aptitude Medical SystemsNot yet recruitingStreptococcus Group A | Strep ThroatUnited States