Background: This study was performed to ultrasonographically demonstrate the changes in relationship between the right IJV and an anatomical landmark in two different head positions: neutral and rotational.
Methods: One hundred patients scheduled for elective surgery under general anesthesia with endotracheal intubation were enrolled in this study. The patients were placed in the supine position with a neutral head position and without a pillow. The apex of the triangle formed by the sternal and clavicular heads of the sternocleidomastoid muscle and clavicle was marked (anatomical landmark point: AL point). The ultrasonography of the neck anatomy was performed, and a mark was placed at the central point of the IJV to the skin (ultrasonography point: US point). The other investigator measured the distances from the AL point to the US point (AL-US distance). The patient's head was then turned 30° to the left; the same procedure was repeated and the AL-US distance was again measured. The changes in AL-US distance were calculated.
Typ studie
Zápis (Aktuální)
Kontakty a umístění
Studijní místa
-
-
-
Seoul, Korejská republika
- Soonchunhyang University Hospital
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Metoda odběru vzorků
Studijní populace
Popis
Inclusion Criteria:
- 100 patients weighing 40 - 100 kg and with heights of 140 - 190 cm
Exclusion Criteria:
- a history of neck surgery or trauma involving the neck, previous IJV-related interventions (e.g., venous catheterization), limitation of neck movement, and a body mass index ≥ 30.
Studijní plán
Jak je studie koncipována?
Detaily designu
Kohorty a intervence
Skupina / kohorta |
Intervence / Léčba |
|---|---|
|
neutral head position
supine with neutral head position
|
AL-US distance measure using the ultrasound in two different head position
|
|
head rotation
supine with 30° head rotation
|
AL-US distance measure using the ultrasound in two different head position
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
anatomical landmark point (AL) - ultrasonography point (US) distance(the distances from the AL point to the US point )
Časové okno: within 5 minutes after itubation
|
The distance between the two points was considered "positive" if the US point was lateral to the AL point and "negative" if it was medial to the AL point.
|
within 5 minutes after itubation
|
Sekundární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
The average depth of the right IJV
Časové okno: within 5 minutes after intubation
|
measure the depth of the right IJV center in ultrasonography
|
within 5 minutes after intubation
|
Spolupracovníci a vyšetřovatelé
Vyšetřovatelé
- Studijní židle: Sun Young Park, Dr., Soonchuhyang University Hospital
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Odhad)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
- LoIJV
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .