Electronic Six-Image Pulse Diagnosis for TCM Syndrome Identification in Sleep Disorders (SIP-TCM)

From Experience to Evidence: Large-Sample Quantitative Modeling of the Six-Image Pulse Framework Using a Modern Pulse Diagnostic Device and Its Performance in TCM Syndrome Identification

This is a prospective, single-center, observational diagnostic accuracy study designed to evaluate whether three-dimensional electronic pulse diagnosis can support traditional Chinese medicine syndrome identification in patients with sleep disorders. Participants underwent standardized symptom assessment, expert traditional Chinese medicine syndrome differentiation, and bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 electronic pulse diagnostic system. Six-position pulse parameters were used to construct a Six-Image pulse vector, which was compared with a symptom-based Six-Image vector. The main purpose of the study is to assess the concordance between electronic pulse-derived features and expert-determined traditional Chinese medicine syndromes.

Přehled studie

Detailní popis

This study was conducted at the Integrated Traditional Chinese and Western Medicine Hospital of Southern Medical University. It was designed as a prospective, single-center, observational diagnostic accuracy study to explore the relationship between objective pulse diagnostic parameters and traditional Chinese medicine syndrome differentiation in patients with sleep disorders.

Eligible participants were adult patients with sleep disorders who were able to complete pulse examination and questionnaire assessment and who provided written informed consent. Patients with acute disease, severe organic cardiovascular disease, anatomical abnormalities of the radial artery, pregnancy, or other conditions unsuitable for pulse signal acquisition were excluded.

Each participant completed a standardized Six-Image Symptom Questionnaire developed according to the traditional Chinese medicine zang-fu image framework. The questionnaire covered six functional image domains, including heart, liver, spleen, lung, kidney, and San Jiao or mingmen-related domains. Expert traditional Chinese medicine syndrome differentiation was independently performed by two senior traditional Chinese medicine physicians. If disagreement occurred, a third senior expert adjudicated the final predominant syndrome, which served as the reference standard.

Pulse signals were acquired using the KY-M-A1 three-dimensional electronic pulse diagnostic system. Bilateral pulse signals were collected from the cun, guan, and chi positions, yielding six pulse sites in total. Participants rested quietly before acquisition, and pulse signals were recorded under standardized conditions. The system extracted pulse waveform parameters, including pulse amplitude-related indices, to construct a Six-Image pulse vector.

The primary analysis evaluates pulse-syndrome concordance by comparing the Six-Image pulse vector with the symptom-based Six-Image vector using cosine similarity. Higher similarity values indicate stronger agreement between pulse-derived features and symptom-based syndrome domains. Expert-determined traditional Chinese medicine syndrome classification is used as the reference standard. Secondary analyses include the diagnostic consistency between instrument-based syndrome differentiation and expert assessment, as well as receiver operating characteristic curve analysis to evaluate the discriminatory performance of the electronic pulse diagnostic system.

Typ studie

Pozorovací

Zápis (Aktuální)

201

Kontakty a umístění

Tato část poskytuje kontaktní údaje pro ty, kteří studii provádějí, a informace o tom, kde se tato studie provádí.

Studijní místa

    • Guangdon
      • Guangzhou, Guangdon, Čína, 510000
        • Integrated Traditional Chinese and Western Medicine Hospital of Southern Medical University

Kritéria účasti

Výzkumníci hledají lidi, kteří odpovídají určitému popisu, kterému se říká kritéria způsobilosti. Některé příklady těchto kritérií jsou celkový zdravotní stav osoby nebo předchozí léčba.

Kritéria způsobilosti

Věk způsobilý ke studiu

  • Dospělý
  • Starší dospělý

Přijímá zdravé dobrovolníky

Ne

Metoda odběru vzorků

Vzorek nepravděpodobnosti

Studijní populace

The study population consisted of adult outpatients and inpatients with sleep disorders recruited from the Integrated Traditional Chinese and Western Medicine Hospital of Southern Medical University. Eligible participants had relatively stable symptoms, were able to complete the standardized Six-Image symptom questionnaire and electronic pulse examination, and provided written informed consent. All participants underwent expert traditional Chinese medicine syndrome differentiation and bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 three-dimensional electronic pulse diagnostic system.

Popis

Inclusion Criteria:

  • Age between 18 and 75 years, regardless of sex.
  • Confirmed diagnosis of sleep disorder with relatively stable symptoms.
  • Ability to complete electronic pulse examination and questionnaire assessment.
  • Provision of written informed consent.

Exclusion Criteria:

  • Acute phase of disease.
  • Severe organic cardiovascular disease, such as severe arrhythmia or heart failure.
  • Anatomical abnormalities of the radial artery or difficulty in pulse signal acquisition.
  • Pregnancy.
  • Other conditions considered unsuitable for pulse data acquisition by the investigators.

Studijní plán

Tato část poskytuje podrobnosti o studijním plánu, včetně toho, jak je studie navržena a co studie měří.

Jak je studie koncipována?

Detaily designu

Kohorty a intervence

Skupina / kohorta
Intervence / Léčba
Patients With Sleep Disorders
Adult patients with sleep disorders who provided written informed consent and underwent standardized Six-Image symptom questionnaire assessment, expert traditional Chinese medicine syndrome differentiation, and bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 three-dimensional electronic pulse diagnostic system. No treatment intervention was assigned in this observational diagnostic accuracy study.
All participants underwent bilateral cun, guan, and chi pulse signal acquisition using the KY-M-A1 three-dimensional electronic pulse diagnostic system. The diagnostic test was used to obtain six-position pulse parameters and construct a Six-Image pulse vector for comparison with symptom-based Six-Image vectors and expert traditional Chinese medicine syndrome classification. No treatment intervention was assigned in this observational diagnostic accuracy study.
Ostatní jména:
  • KY-M-A1
  • Electronic Pulse Diagnostic System
  • Six-Image Pulse Diagnosis
All participants underwent expert traditional Chinese medicine syndrome differentiation based on symptom profiles, tongue assessment, pulse palpation, and clinical evaluation. Syndrome differentiation was independently performed by two senior traditional Chinese medicine physicians. In cases of disagreement, a third senior expert adjudicated the final predominant syndrome. The expert-determined syndrome classification served as the reference standard for evaluating the diagnostic performance of the electronic pulse diagnostic system.
Ostatní jména:
  • Expert TCM Syndrome Assessment
  • Reference Standard Syndrome Differentiation

Co je měření studie?

Primární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Pulse Amplitude Index at the Six Pulse Positions
Časové okno: At the baseline study assessment visit
The Pulse Amplitude Index was derived from pulse signals acquired by the KY-M-A1 three-dimensional electronic pulse diagnostic system at the bilateral cun, guan, and chi positions. Pulse Amplitude Index values from the six pulse positions were used to objectively characterize pulse wave amplitude distribution and construct the Six-Image pulse vector.
At the baseline study assessment visit
Pulse-Syndrome Concordance Assessed by Cosine Similarity
Časové okno: At the baseline study assessment visit
Pulse-syndrome concordance was quantified using cosine similarity between the Six-Image pulse vector derived from electronic pulse diagnostic parameters and the Six-Image symptom vector derived from structured traditional Chinese medicine symptom assessment. The similarity score ranges from 0 to 1, with higher values indicating greater concordance between pulse-derived features and symptom-based syndrome domains.
At the baseline study assessment visit
Diagnostic Consistency Between Electronic Pulse Diagnosis and Expert TCM Syndrome Differentiation
Časové okno: At the baseline study assessment visit
Diagnostic consistency was evaluated by comparing instrument-based syndrome differentiation with expert-determined traditional Chinese medicine syndrome classification. Expert syndrome differentiation served as the reference standard. Consistency was assessed using sensitivity, specificity, and overall accuracy.
At the baseline study assessment visit

Sekundární výstupní opatření

Měření výsledku
Popis opatření
Časové okno
Area Under the Receiver Operating Characteristic Curve for Electronic Pulse Diagnosis
Časové okno: At the baseline study assessment visit
Receiver operating characteristic curve analysis was performed to evaluate the discriminatory performance of pulse-syndrome concordance and instrument-based syndrome classification. The area under the curve was calculated to quantify overall diagnostic discrimination.
At the baseline study assessment visit
Six-Image Pulse Distribution Patterns
Časové okno: At the baseline study assessment visit
Six-Image radar plots and distribution heat maps were used to visualize Pulse Amplitude Index patterns across the six pulse positions and to characterize pulse distribution patterns corresponding to different traditional Chinese medicine syndrome domains.
At the baseline study assessment visit
Case-Based Six-Position Pulse Map Characteristics
Časové okno: At the baseline study assessment visit
Representative case-level Six-Image pulse maps were generated using Pulse Amplitude Index values from the six pulse positions to illustrate the individualized application of electronic pulse diagnosis in traditional Chinese medicine syndrome differentiation.
At the baseline study assessment visit

Spolupracovníci a vyšetřovatelé

Zde najdete lidi a organizace zapojené do této studie.

Termíny studijních záznamů

Tato data sledují průběh záznamů studie a předkládání souhrnných výsledků na ClinicalTrials.gov. Záznamy ze studií a hlášené výsledky jsou před zveřejněním na veřejné webové stránce přezkoumány Národní lékařskou knihovnou (NLM), aby se ujistily, že splňují specifické standardy kontroly kvality.

Hlavní termíny studia

Začátek studia (Aktuální)

1. ledna 2025

Primární dokončení (Aktuální)

30. září 2025

Dokončení studie (Aktuální)

30. září 2025

Termíny zápisu do studia

První předloženo

4. července 2026

První předloženo, které splnilo kritéria kontroly kvality

4. července 2026

První zveřejněno (Aktuální)

10. července 2026

Aktualizace studijních záznamů

Poslední zveřejněná aktualizace (Aktuální)

10. července 2026

Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality

4. července 2026

Naposledy ověřeno

1. července 2026

Více informací

Termíny související s touto studií

Plán pro data jednotlivých účastníků (IPD)

Plánujete sdílet data jednotlivých účastníků (IPD)?

NE

Popis plánu IPD

No individual participant data will be shared publicly. The study dataset includes participant-level clinical information, traditional Chinese medicine symptom questionnaire data, expert syndrome differentiation results, and electronic pulse signal parameters. These data were collected under institutional ethics approval and written informed consent for the present study, and public or external sharing of individual participant data was not included in the consent materials.

Requests for de-identified aggregate data or additional methodological information may be directed to the principal investigator, Mingpeng Luo, at 872462051@qq.com. Any data access request will be reviewed by the study team and will be subject to institutional policy and ethics committee approval.

Informace o lécích a zařízeních, studijní dokumenty

Studuje lékový produkt regulovaný americkým FDA

Ne

Studuje produkt zařízení regulovaný americkým úřadem FDA

Ne

Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .

Předplatit