Detailní popis
This randomized split-mouth controlled clinical trial aims to compare pain experienced during anterior maxillary infiltration anesthesia using Transcodent painless needle tips versus conventional dental needle tips. Dental injection pain is a common source of anxiety and may negatively affect patient acceptance of dental treatment. Recent advances in needle design, including the three-edge lancet grinding bevel and silicone-coated cannula of the Transcodent needle, have been developed to reduce tissue resistance during penetration and improve patient comfort.
A total of 60 adult patients requiring bilateral maxillary anterior infiltration anesthesia for dental treatment will be recruited from the Department of Operative Dentistry, Saidu College of Dentistry, Swat. Eligible participants will receive two supraperiosteal injections, one with a Transcodent painless needle tip and one with a conventional needle tip, on opposite sides of the maxillary arch. The order of needle use and injection site will be randomized using a balanced block randomization method. Prior to injection, 20% benzocaine topical anesthetic gel will be applied for two minutes. Each injection will consist of 0.9 mL of 2% lidocaine with 1:100,000 epinephrine administered over 30 seconds by the same operator.
Pain perception will be assessed immediately after each injection using a 100-mm Visual Analog Scale (VAS), where 0 indicates no pain and 100 indicates the worst imaginable pain. The primary outcome is the difference in mean VAS pain scores between Transcodent and conventional needle tips. Data will be analyzed using paired statistical methods appropriate for the distribution of the data.
The findings of this study will provide local evidence regarding the effectiveness of Transcodent painless needle tips in reducing injection-related pain during maxillary infiltration anesthesia and may contribute to improving patient comfort and reducing dental anxiety during routine dental procedures.
Typ studie
Zápis (Odhadovaný)
Fáze
- Nelze použít
Kontakty a umístění
Studijní kontakt
- Jméno: Azra Umar, BDS
- Telefonní číslo: +92 331 8080135
- E-mail: drumarhussain@gmail.com
Studijní místa
-
-
-
Mingora Swat, Pákistán, 19200
- Saidu Collage of Dentistry, Saidu Sharif , Swat
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
Adults aged 18 to 60 years. Patients requiring bilateral maxillary anterior infiltration anesthesia for dental treatment.
Patients undergoing endodontic procedures involving maxillary canines or premolars.
Presence of healthy maxillary teeth on both sides suitable for infiltration anesthesia.
Individuals with no systemic disease or neurological disorder affecting pain perception.
Ability to understand the study procedures and provide written informed consent.
Both male and female participants.
Exclusion Criteria:
Pregnant or lactating women. Use of analgesics, sedatives, or other pain-modifying medications within the previous 12 hours.
Known allergy or hypersensitivity to local anesthetics, benzocaine, lidocaine, or epinephrine.
Presence of active infection, inflammation, swelling, or pathology at the injection site.
Severe dental anxiety, needle phobia, or inability to cooperate with study procedures.
Individuals unable or unwilling to provide informed consent.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Experimentální: Sequence A: Transcodent Needle First
Participants receive anterior maxillary infiltration anesthesia using a Transcodent painless needle tip with a three-edge lancet grinding bevel and silicone-coated cannula.
Pain is assessed immediately after injection using a 100-mm Visual Analog Scale (VAS).
|
A dental injection needle with a three-edge lancet grinding bevel and silicone-coated cannula designed to reduce tissue resistance and injection pain during anterior maxillary infiltration anesthesia.
A standard dental injection needle with a conventional bevel design used for anterior maxillary infiltration anesthesia.
|
|
Experimentální: Sequence B: Conventional Needle First
Participants receive anterior maxillary infiltration anesthesia using a conventional dental needle tip.
Pain is assessed immediately after injection using a 100-mm Visual Analog Scale (VAS).
|
A dental injection needle with a three-edge lancet grinding bevel and silicone-coated cannula designed to reduce tissue resistance and injection pain during anterior maxillary infiltration anesthesia.
A standard dental injection needle with a conventional bevel design used for anterior maxillary infiltration anesthesia.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Pain Score During Anterior Maxillary Infiltration Injection
Časové okno: Immediately after each injection
|
Pain perception measured using a 100-mm Visual Analog Scale (VAS), where 0 indicates no pain and 100 indicates the worst imaginable pain.
Pain scores will be recorded immediately after administration of infiltration anesthesia using either a Transcodent
|
Immediately after each injection
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Azra Umar, Saidu College of Dentistry, Swat, Paksitan
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Odhadovaný)
Primární dokončení (Odhadovaný)
Dokončení studie (Odhadovaný)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
- SCD-OPER-2026-06
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Popis plánu IPD
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .