Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Correlation of Donor-specific Anti-endothelial Cells

21. august 2018 opdateret af: John Friedewald, Northwestern University

A Phase II, Prospective, Single-center Study: Correlation of Donor-specific Anti-precursor Endothelial Cells With Transplant Outcome for Recipients of Living-donor Kidney Transplants, Are Auto-antibodies Important.

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor human leukocyte antigens (HLA). Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation the investigators would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.

Studieoversigt

Status

Afsluttet

Detaljeret beskrivelse

Antibody Mediated Rejection (AMR) is a major complication of solid organ transplantation. The main reason for AMR is pre-formed, or de-novo, donor specific antibodies against the donor HLA antigens. Additional potential targets are antibodies against MIC-A antigens or antibodies against targets expressed on the donor endothelial cells.

Until recently, no specific means were available to test for the presence of donor-specific endothelial cell antibodies. The newly introduced XM-One AbSorber® assay allows isolating precursor endothelial cells from donor peripheral blood, and thus assessing the presence of donor-specific endothelial cell antibodies.

XM-One AbSorber® is an in-vitro assay that allows for the specific enrichment of precursor endothelial cells which in turn promotes endothelial cells specific cross match testing.

This assay is currently being used in an on-going Northwestern University (NU) research study (STU#00029988). The preliminary results of this study indicate that indeed some of the patients test positive against their respective donors. One potential explanation for this observation, that was not previously entertained, is that the antibodies causing the positive cross match response are actually of autoimmune nature. In order to rule-out such a potential explanation we would like to further test these patients by performing an autologous XM-One AbSorber® assay in which the recipient sera will be incubated with the patients' own cells (as opposed to the respective donor cells in the parental study). This information is crucial for proper analysis of the data obtained in the NU STU#00029988 study.

Initial data from our laboratory indicates that the antigens identified by the XM-One Absorber® assay differ from the HLA antigens usually identified by routine cross match assays. Moreover, we were able to document that this is a polymorphic system and therefore identifying a donor-specific source is critical.

Of the 150 patients already studied under NU research protocol STU#00029988 we found that 19 patients exhibited a positive response in a donor-specific XM-One AbSorber® assay. In this current research protocol study we want to follow-up on the specimens that exhibited a positive response in a donor-specific XM-One AbSorber® assay and perform an autologous XM-One AbSorber® assay to validate the clinical significance of our results.

There has been one multicenter study reported indicating the "XM-One AbSorber® is a quick, easy to perform on whole blood samples and identifies patients at risk for rejection and reduced graft function not identified by conventional lymphocyte cross matches" The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.

The secondary objective is to assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.

In this prospective study we plan to include all XM-One AbSorber® positive test results from all recipients of living-donor kidney transplants performed at Northwestern Memorial Hospital (NMH) since May 19, 2010 initial Institutional Review Board (IRB) approval until 250 transplants are performed. For this research protocol we will be targeting patients to consent only these individuals who have received a XM-One AbSorber® positive test result.

Each donor / recipient pair are required to send peripheral blood samples to the HLA laboratory prior to the scheduled transplant in order to perform lymphocyte cross match (to detect donor specific HLA antibodies; this is (SOC) standard of care). Left over serum and cells from these tests are being used to isolate an enriched precursor endothelial cell population and perform the XM-One AbSorber® assay (NU research protocol #STU00029988).

XM-One AbSorber® assay results - both autologous and allogeneic - will be captured and compared with graft outcome measurements at 3, 6, and 12 months post-transplant. Transplant outcome will be recorded as creatinine levels at the specific time points, protocol and for-cause biopsy results within the first year post transplant, diagnosis of acute cellular or humoral rejection, variation in immunosuppression levels, and any other complications.

Patients that exhibit a positive XM-One AbSorber® allogeneic cross match result will be requested to donate 4 green top tubes of peripheral blood. Cells obtained from this blood will be used in an autologous XM-One AbSorber® cross match assay using the original serum sample used for the allogeneic XM-One AbSorber® cross match assay.

Undersøgelsestype

Observationel

Tilmelding (Faktiske)

16

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Illinois
      • Chicago, Illinois, Forenede Stater, 60611
        • Northwestern Memorial Hospital

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Prøveudtagningsmetode

Sandsynlighedsprøve

Studiebefolkning

Living-Donor kidney transplant recipients at Northwestern Memorial Hospital 18 year of age or older.

Beskrivelse

Inclusion Criteria:

  1. patients older than 18 years of age
  2. patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result

Exclusion Criteria:

  1. patients undergoing deceased donor kidney transplant
  2. patients younger than 18 years of age

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

Kohorter og interventioner

Gruppe / kohorte
Renal Transplant Recipients
Patients undergoing living-donor kidney transplant at NMH who have a positive XM-One AbSorber® positive test result.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
To complete additional testing for accuracy
Tidsramme: June 2011 - February 2012
The primary objective is to complete additional testing for accuracy to determine whether antibodies directed at donor-specific endothelial cell effect transplant outcome.
June 2011 - February 2012

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
To assess the frequency of autologous antibodies.
Tidsramme: June 2011 - February 2012
To assess the frequency of autologous antibodies that may be falsely reported as donor-specific anti-endothelial antibodies in our patient population. The single center research study we here at Northwestern University have been working on since May 19, 2010 thus far has resulted in 19 out of 150 specimens tested, have positive results based on the XM-One AbSorber® assay.
June 2011 - February 2012

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: John Friedewald, MD, Northwestern University

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Faktiske)

1. juni 2011

Primær færdiggørelse (Faktiske)

1. februar 2012

Studieafslutning (Faktiske)

1. december 2017

Datoer for studieregistrering

Først indsendt

1. marts 2012

Først indsendt, der opfyldte QC-kriterier

6. marts 2012

Først opslået (Skøn)

7. marts 2012

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

23. august 2018

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

21. august 2018

Sidst verificeret

1. august 2018

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • XM-One AbSorber

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner