Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Effects of Radiofrequency on Located Adiposity

9. september 2015 opdateret af: Patricia Viana da Rosa, Federal University of Health Science of Porto Alegre

Effects of Radiofrequency on Located Adiposity: A Pilot Study

Nowadays increasingly quest for improved physical appearance, gradually developing the medicine of beauty, where the radio fits as an additional tool in helping some aging processes and maintenance of body shape. The aim of this study was to evaluate and compare the changes in the thickness of adipose tissue and blood levels of some biochemical markers of sedentary and active women who underwent radio frequency technique via ultrasound imaging and laboratory tests. Seven (7) sessions were held, each lasting 20 minutes each, 22 volunteers allocated into two groups, sedentary and physically active. Measures ultrasound image were collected at baseline, pre-treatment and post-treatment period period and serum biochemical parameters (lipid profile, liver and kidney) for the pre-treatment and post-treatment.

Studieoversigt

Status

Afsluttet

Betingelser

Intervention / Behandling

Detaljeret beskrivelse

The demand for treatments for localized adiposity reduction increasingly gaining ground in beauty clinics due to the constant search for the perfect body and the current standards of beauty. The localized adiposity is characterized by a hypertrophy of unilocular fat cells that occurs in some parts of the body, especially the flanks and abdomen and often food programs combined with physical activity are not enough and requires a complementary treatment for redefinition of body shapes. The radio frequency is a non-invasive technique that emits electromagnetic waves generate heat in the skin layers. The technique is indicated for the treatment of edema fibro geloid (EGF), wrinkles, sagging and is also observed lipolytic effect acting directly at the level of accumulated fat cells helping to reduce the fat layer. With this vision, the investigators seek to evaluate the effects of Radio Frequency on localized f in patients who have this fat in the abdominal region, comparing a group of sedentary women with a group of women engaged in physical activities. Also will evaluate biochemical and anthropometric parameters so that they can provide indications about the effects of radio frequency in the human body.

This is a pilot study. The sample will consist of 30 females volunteers who participate, respecting the criteria for inclusion and exclusion previously cited by reading and signing the Informed Consent and Clarified.

The sample consists of 30 participants, divided into two groups, with 15 individuals will be regular exercise practitioners and 15 are sedentary, with participants from each group will undergo a 4-week control period between the first (base period) and second (pre-treatment) evaluations. Participants will be instructed to not change their respective routine activities.

For physical activity practitioner should perform at least 150 minutes of aerobic exercise of moderate intensity in the week, or at least 75 minutes of vigorous physical activity, or even that combine physical activity of moderate and vigorous intensity during the week. Both groups will make 12 sessions on individual radio frequency applications, twice a week, total of 6 weeks treatment.

To monitor the results, diagnostic ultrasound will be used to measure the fat layer. To collect the individual will be in the supine position with a pillow under the lumbar spine. The head will be positioned above the navel and the fat thickness is measured from the inner layer of the skin to the aponeurosis of the rectus abdominis muscle in the middle of the Alba line area. To measure the fatty layer of flanks the head that was in the umbilicus will be displaced laterally with the individual still in the supine position. The head is in the transverse plane will be asked to the individual who holds the air on exhalation to collect the image. The fat thickness measurements are made with a linear probe (7.5 MHz) with a depth of 4 to 5cm. The parameters used in this study have been previously tested and showed no health risk.

Among the methods used for assessing body composition, electrical bioimpedance has been widely used, especially by high speed in processing information, being a noninvasive method, practical, reproducible, which estimates, in addition to body components, the distribution of fluid in the intracellular and extracellular spaces, as well as the quality, size and cell integrity. For assessment of body composition, Bioelectrical impedance analysis (BIA) technique is based on the model of a cylindrical conductor with length and uniform and homogeneous cross-cutting area, to which the human body resembles. Evaluations shall be performed by a professional with training and experience in this type of analysis. For the examination, will be used Maltron BF-900 model unit and will be adopted the protocol recommendations proposed by the European Society for Clinical Nutrition and Metabolism:

  • Assess body mass and height of the individual at the time of examination;
  • Individual fasting and not drinking alcohol for at least 8 hours;
  • Urinate before the exam;
  • Do not perform physical exercise in the eight hours before the test;
  • No injury to the skin where the electrode will be;
  • Clean the skin with alcohol;
  • Position the electrodes always on the same side of the body;
  • Minimum of 5 cm distance between the electrodes;
  • Separated from the stem by arms 30 and legs apart by 45 °;
  • Environment should be neutral (no electric or magnetic field);
  • Notice the shape of the body to the risk of any possible anomaly (edema, amputation, atrophy, scoliosis, dystrophy);
  • In case of obesity, use of electricity insulating material (towel, for example) between the arm and torso, and between the thighs;
  • When prostheses or implants, to measure the opposite side;
  • Do not use metal objects in the examination as earrings, bracelets, watches and the like.

It is not indicated for individuals who have pacemaker and who are in pregnancy.

Anthropometric measurements will be measured by a previously trained evaluator. The height is determined by the balance rule coupled with a degree in 1 mm, with the individual back to this, in an upright standing position, feet together, and trying to put the posterior surface of heels, pelvic and shoulder girdle in contact with the instrument. Prior to the first session and after the last session will be measured body weight, skin suprailiac and abdominal folds, waist circumference, waist circumference, hip circumference and waist-hip ratio calculation.

Body weight will be measured through traditional mechanical scale with 100g graduation, with front man for the same, in the upright position, feet together, wearing light clothes and without shoes. Based on these two measurements will be done calculating the Body Mass Index, kg ÷ height x height.

The skinfold measure used to estimate the percentage of body fat will be taken using caliper. The supra-iliac and abdominal folds will be measured. The suprailiac preaches will be measured, taking as anatomical reference the iliac crest, in an oblique direction to the longitudinal axis of the body, plying middle region located between the last rib and the iliac crest on the medial axillary line. Since the abdominal crease is measured as taking anatomical reference umbilicus, plying up the region located 1 to 3 cm to the right of scar parallel to the longitudinal axis of the body.

The ratio of waist to hip index is the result of the equation that divides the circumference of the abdomen (cm) by hip circumference (cm). The measurement of waist circumference will be measured with the individual standing upright during the expiratory phase of respiration, using flexible measuring tape 1.5m, accurate to one decimal place, with ribbon positioned parallel to the floor, at least measured between the iliac crest and the last rib.

In Radio Frequency procedure will be used Dermosux RF equipment to decrease localized fat in the abdomen and flanks. The parameters are: maximum power of 50 Watts at a frequency of 1 MHz and will take place the measurement of skin temperature with a digital thermometer, keeping always between 40 - 42 ° C in the quadrants of the abdominal and flank region. The handle is used with continuous and repetitive movements with light pressure. A glycerin oil film over the treatment area as coupling means will be used.

The sessions will be held 2 times a week for six consecutive weeks. The time of each session will be around 40 minutes, and will be 10 minutes in the area for median-right and another 10 minutes in the area for median-left with the patient in the supine position. With the patient in the lateral decubitus will apply an additional 10 minutes on the right flank region and 10 minutes on the left flank region. The schedule of sessions will be marked in accordance with the provision of the sample. It will also be directed at the first session the importance of voluntary not change eating habits or daily lifestyle habits such as physical activity, smoking and alcohol.

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

30

Fase

  • Ikke anvendelig

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 40 år (Voksen)

Tager imod sunde frivillige

Ja

Køn, der er berettiget til at studere

Kvinde

Beskrivelse

Inclusion Criteria:

  • Sedentary
  • physically active

Exclusion Criteria:

-

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Dermosux RF
The group received the radio frequency for 20 minutes with the frequency of 1 MHz with 40 W.
The radio frequency was used for 20 min in the abdomen and flanks, once per week for 7 weeks.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Use of radio frequency reduce the layer of fat in abdominal area
Tidsramme: 7 weeks
7 weeks

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Laura P Bem, Federal University of Health Science of Porto Alegre

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. maj 2014

Primær færdiggørelse (Faktiske)

1. maj 2014

Studieafslutning (Faktiske)

1. august 2014

Datoer for studieregistrering

Først indsendt

27. august 2015

Først indsendt, der opfyldte QC-kriterier

9. september 2015

Først opslået (Skøn)

11. september 2015

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Skøn)

11. september 2015

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

9. september 2015

Sidst verificeret

1. september 2015

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • 23686013.9.0000.5345

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Fedme

Kliniske forsøg med Dermosux RF

Abonner