- ICH GCP
- US Clinical Trials Registry
- Klinisk forsøg NCT07603167
p-PHOTOLARYNX- ANTHEM: Photon-Counting CT in Laryngeal Cancer Staging (H&NRAD-2025-01)
p-PHOTOLARYNX- ANTHEM: Pilot Photon-Counting CT Evaluation of the Paraglottic Space and Cartilage Involvement in Laryngeal Cancer
Laryngeal cancer can affect speaking, swallowing, and breathing. Treatment selection depends on accurately defining tumor spread within the larynx, particularly invasion of the paraglottic space, thyroid cartilage, and subglottic region. Understaging may lead to insufficient treatment and recurrence, whereas overstaging may result in unnecessarily aggressive surgery and impaired quality of life.
CT and MRI are routinely used for local staging, but both have limitations. Conventional CT may have limited soft-tissue and cartilage contrast, while MRI is more time-consuming, motion-sensitive, and not feasible in all patients. Photon-counting CT (PCCT) is a new CT technology offering higher spatial resolution, improved tissue contrast, and reconstructions at different energy levels.
This study evaluates whether PCCT performed during phonation, while the patient produces a sustained sound, can improve local staging of laryngeal cancer. Phonation may better separate and display laryngeal structures, improving detection of tumor extension.
The main hypothesis is that optimized phonation PCCT reconstructions can assess tumor spread more accurately than standard CT and may approach MRI performance. Participants undergo PCCT as part of routine preoperative imaging. Images are reconstructed using different settings and reviewed by radiologists for image quality and tumor extension. When surgery is performed, imaging findings are compared with surgical and histopathological results.
The study aims to identify the most accurate PCCT reconstruction strategy to support better treatment planning in laryngeal cancer.
Studieoversigt
Status
Betingelser
Intervention / Behandling
Detaljeret beskrivelse
This is a prospective, single-center observational imaging study designed to evaluate the diagnostic performance of photon-counting computed tomography (PCCT) acquired during phonation for local staging of biopsy-proven laryngeal squamous cell carcinoma.
Study Overview and Imaging Workflow
Eligible adult patients with histologically confirmed laryngeal squamous cell carcinoma referred for preoperative imaging undergo contrast-enhanced PCCT as part of routine clinical work-up. PCCT examinations are performed on a dedicated photon-counting CT system using a standardized acquisition protocol optimized for ultra-high-resolution imaging of the larynx during phonation. Imaging is acquired in the venous phase under sustained vocalization to enhance functional and morphological assessment of glottic and subglottic structures.
For each acquisition, multiple reconstructions are generated, including ultra-high-resolution virtual monoenergetic images (VMIs) at predefined energy levels and different reconstruction kernels. A 70-keV reconstruction with standard slice thickness is included as an energy-integrating detector (EID)-CT-like reference. When available, previously acquired conventional CT and/or MRI performed as part of standard care are included for comparative analysis. Surgical histopathology serves as the reference standard for local tumor extension.
Qualitative Image Assessment
Qualitative analysis is restricted to phonation acquisitions to maximize clinical relevance and reduce reader burden. Four expert head and neck radiologists independently review anonymized and randomized datasets, blinded to reconstruction parameters. For each dataset, readers assign a qualitative diagnostic quality score using a five-point Likert scale and evaluate tumor extension into the paraglottic space, thyroid cartilage (with distinction between inner cortical erosion and full-thickness invasion), and subglottic space using predefined ordinal scoring systems. Multiplanar reformations aligned with the glottic plane and axis are mandatorily assessed as part of each dataset.
Quantitative Image Assessment
Quantitative analysis is performed by two independent observers on a dedicated workstation. Standardized regions of interest (ROIs) are placed in the primary tumor, adjacent non-tumoral laryngeal tissues, subcutaneous fat (for noise estimation), and the common carotid artery (vascular reference). ROIs are defined on a representative axial slice and propagated across all reconstructions to ensure measurement consistency. Quantitative metrics include attenuation values, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR).
Data Management and Quality Assurance
Data are collected using structured electronic case report forms (eCRFs) derived from hospital source documents. All imaging data are anonymized prior to analysis. Quality assurance procedures are based on written standard operating procedures at the sponsor site and include verification of data completeness, internal consistency checks, and cross-validation of imaging assessments with source data (radiology reports, surgical and pathology records). Access to source data is permitted for authorized personnel in accordance with Good Clinical Practice and data protection regulations.
Statistical Analysis Plan
Given the exploratory, pilot nature of the study, the planned sample size of 60 patients is based on feasibility and the need to support descriptive and comparative multi-dataset, multi-reader analyses rather than formal hypothesis testing. Quantitative variables are summarized using appropriate descriptive statistics based on data distribution. Interobserver agreement is assessed using intraclass correlation coefficients for quantitative measures and Fleiss' kappa for ordinal qualitative scores.
The effects of VMI energy level and reconstruction kernel on quantitative and qualitative outcomes are evaluated using mixed-effects models accounting for repeated measures within patients and readers. Diagnostic performance of PCCT, and where available conventional CT and MRI, is assessed using sensitivity, specificity, predictive values, and receiver operating characteristic analysis with histopathology as the reference standard. Adjustment for multiple comparisons is applied when appropriate.
Handling of Missing Data
Missing or non-evaluable data (e.g., due to severe artifacts or unavailable histopathology) are documented explicitly. Analyses are primarily conducted on available data without imputation, and sensitivity analyses may be performed to assess the impact of missing values.
Ethical and Operational Considerations
The study does not modify standard clinical management. No study-specific adverse events are anticipated. All procedures comply with the Declaration of Helsinki, Good Clinical Practice, and applicable regulatory requirements. Written informed consent is obtained prior to participation.
Undersøgelsestype
Tilmelding (Anslået)
Kontakter og lokationer
Studiesteder
-
-
-
Rozzano, Italien, 20089
- Humanitas Research Hospital
-
-
Deltagelseskriterier
Berettigelseskriterier
Aldre berettiget til at studere
- Voksen
- Ældre voksen
Tager imod sunde frivillige
Prøveudtagningsmetode
Studiebefolkning
Beskrivelse
1. SELECTION CRITERIA
Inclusion Criteria
- Adults (≥18 years)
- Biopsy-proven laryngeal cancer squamous cell carcinoma
- Candidate for surgical staging able to undergo PCCT
Exclusion criteria
- Renal failure
- Allergy to contrast medium
- Refusal of informed consent
- Lack of histopathologic confirmation
- Histopathologic diagnosis of non laryngeal tumors
- Poor image quality due to severe artifacts
Studieplan
Hvordan er undersøgelsen tilrettelagt?
Design detaljer
Kohorter og interventioner
Gruppe / kohorte |
Intervention / Behandling |
|---|---|
|
Biopsy-Proven Laryngeal Squamous Cell Carcinoma Patients
A total of sixty patients, with biopsy-proven and clinical laryngeal squamous cell carcinoma
|
Photon-Counting CT (PCCT) will be performed using the Siemens Healthineers NAEOTOM Alpha, the latest generation of CT technology and the first system to apply photon-counting detector technology to laryngeal imaging.
Its CdTe detectors count individual photons and measure their energy, enabling true spectral imaging with ultra-high spatial resolution (voxel size down to 0.2 mm).
Multi-energy maps significantly improve tissue differentiation, allowing clearer distinction between paraglottic fat, non-ossified thyroid cartilage, and tumor tissue.
The technology also reduces artifacts and enhances contrast, enabling detailed evaluation of the laryngeal cartilages and paraglottic space.
|
Hvad måler undersøgelsen?
Primære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Diagnostic Accuracy of Phonation Photon-Counting CT (PCCT) for Local Tumor Extension
Tidsramme: From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
Description: To evaluate the diagnostic accuracy of phonation PCCT in identifying paraglottic space invasion, thyroid cartilage invasion (including distinction between inner cortical erosion and full-thickness invasion), and subglottic extension, using surgical and histopathological findings as the reference standard. |
From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
|
Identification of the Optimal PCCT Reconstruction for Local Staging
Tidsramme: From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
To identify the best-performing phonation PCCT reconstruction (defined by VMI energy level and reconstruction kernel) for each anatomical target (paraglottic space, thyroid cartilage, subglottic space), based on diagnostic accuracy relative to histopathology.
|
From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
Sekundære resultatmål
Resultatmål |
Foranstaltningsbeskrivelse |
Tidsramme |
|---|---|---|
|
Robustness of Local Staging Across PCCT Reconstructions
Tidsramme: From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
To assess variability in local staging classification (paraglottic space invasion, cartilage involvement, subglottic extension) across different phonation PCCT reconstructions, including staging upgrades or downgrades between datasets.
|
From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
|
Interobserver Agreement for Qualitative and Staging Assessments
Tidsramme: From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
To evaluate interobserver reproducibility among readers for qualitative diagnostic quality scores and ordinal staging assessments of paraglottic space invasion, cartilage involvement, and subglottic extension. . |
From completion of baseline phonation PCCT imaging to histopathological correlation, assessed up to 12 weeks.
|
|
Tumor attenuation
Tidsramme: At baseline imaging, before surgery.
|
Mean attenuation measured in Hounsfield Units (HU) within tumor regions of interest.
|
At baseline imaging, before surgery.
|
|
Image noise
Tidsramme: At baseline imaging, before surgery.
|
Image noise defined as the standard deviation of attenuation measured in a homogeneous region (e.g., subcutaneous fat).
|
At baseline imaging, before surgery.
|
|
Signal-to-noise ratio (SNR)
Tidsramme: At baseline imaging, before surgery.
|
Signal-to-noise ratio calculated as mean tumor attenuation divided by image noise.
|
At baseline imaging, before surgery.
|
|
Contrast-to-noise ratio (CNR)
Tidsramme: At baseline imaging, before surgery.
|
Contrast-to-noise ratio calculated as the difference in attenuation between tumor and reference tissue divided by image noise.
|
At baseline imaging, before surgery.
|
|
CT dose index volume (CTDIvol)
Tidsramme: At baseline imaging, before surgery.
|
Volume CT dose index measured in milligray (mGy)
|
At baseline imaging, before surgery.
|
|
Dose-length product (DLP)
Tidsramme: At baseline imaging, before surgery.
|
Dose-length product measured in milligray-centimeters (mGy·cm).
|
At baseline imaging, before surgery.
|
|
Effective dose
Tidsramme: At baseline imaging, before surgery.
|
Estimated effective radiation dose expressed in millisieverts (mSv).
|
At baseline imaging, before surgery.
|
|
Comparison of PCCT with Conventional CT and MRI
Tidsramme: From completion of phonation PCCT imaging to completion of multimodality image review and histopathological correlation, assessed up to 12 weeks.
|
To compare the diagnostic performance of phonation PCCT with conventional energy-integrating detector CT and MRI, when available, using histopathology as the reference standard.
|
From completion of phonation PCCT imaging to completion of multimodality image review and histopathological correlation, assessed up to 12 weeks.
|
Samarbejdspartnere og efterforskere
Sponsor
Publikationer og nyttige links
Generelle publikationer
- Kuno H, Sakamaki K, Fujii S, Sekiya K, Otani K, Hayashi R, Yamanaka T, Sakai O, Kusumoto M. Comparison of MR Imaging and Dual-Energy CT for the Evaluation of Cartilage Invasion by Laryngeal and Hypopharyngeal Squamous Cell Carcinoma. AJNR Am J Neuroradiol. 2018 Mar;39(3):524-531. doi: 10.3174/ajnr.A5530. Epub 2018 Jan 25.
- Preda L, Conte G, Bonello L, Giannitto C, Tagliabue E, Raimondi S, Ansarin M, De Benedetto L, Cattaneo A, Maffini F, Bellomi M. Diagnostic accuracy of surface coil MRI in assessing cartilaginous invasion in laryngeal tumours: Do we need contrast-agent administration? Eur Radiol. 2017 Nov;27(11):4690-4698. doi: 10.1007/s00330-017-4840-x. Epub 2017 May 5.
- Becker M, Zbaren P, Casselman JW, Kohler R, Dulguerov P, Becker CD. Neoplastic invasion of laryngeal cartilage: reassessment of criteria for diagnosis at MR imaging. Radiology. 2008 Nov;249(2):551-9. doi: 10.1148/radiol.2492072183.
- Yu Z, Leng S, Kappler S, Hahn K, Li Z, Halaweish AF, Henning A, McCollough CH. Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner. J Med Imaging (Bellingham). 2016 Oct;3(4):043503. doi: 10.1117/1.JMI.3.4.043503. Epub 2016 Dec 14.
- Becker M, Zbären P, Casselman JW, et al. MRI in the Preoperative Staging of Laryngeal Cancer. AJNR. 2010;31(4):592-599. doi:10.3174/ajnr.A1912
- Castelijns JA, van den Brekel MW. Imaging of Laryngeal Cancer. Eur J Radiol. 2008;66(3):501-517. doi:10.1016/j.ejrad.2008.01.046
- Leng S, Bruesewitz M, Tao S, et al. Photon-Counting CT: Impact on Noise, Spatial Resolution, and Image Quality. Radiology. 2020;297(3):738-746. doi:10.1148/radiol.2020201407
- Li H, Yadava G, Procopiou M, et al. Photon-Counting Detector CT: Clinical Applications of an Emerging Technology. Radiographics. 2022;42(5):1439-1456. doi:10.1148/rg.220014
- Hermans R, Boomgaert L, Cockmartin L, Binst J, De Stefanis R, Bosmans H. Photon-counting CT allows better visualization of temporal bone structures in comparison with current generation multi-detector CT. Insights Imaging. 2023 Jul 3;14(1):112. doi: 10.1186/s13244-023-01467-w.
- Benson JC, Campeau NG, Diehn FE, Lane JI, Leng S, Moonis G; ASHNR Research Committee. Photon-Counting CT in the Head and Neck: Current Applications and Future Prospects. AJNR Am J Neuroradiol. 2024 Aug 9;45(8):1000-1005. doi: 10.3174/ajnr.A8265.
Datoer for undersøgelser
Studer store datoer
Studiestart (Faktiske)
Primær færdiggørelse (Anslået)
Studieafslutning (Anslået)
Datoer for studieregistrering
Først indsendt
Først indsendt, der opfyldte QC-kriterier
Først opslået (Faktiske)
Opdateringer af undersøgelsesjournaler
Sidste opdatering sendt (Faktiske)
Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier
Sidst verificeret
Mere information
Begreber relateret til denne undersøgelse
Yderligere relevante MeSH-vilkår
Andre undersøgelses-id-numre
- 4981
Plan for individuelle deltagerdata (IPD)
Planlægger du at dele individuelle deltagerdata (IPD)?
IPD-planbeskrivelse
Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter
Studerer et amerikansk FDA-reguleret lægemiddelprodukt
Studerer et amerikansk FDA-reguleret enhedsprodukt
Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .
Kliniske forsøg med Larynxkræft
-
University of British ColumbiaAfsluttet
-
University of British ColumbiaAfsluttet
-
Assiut UniversityIkke rekrutterer endnu
-
Zagazig UniversityRekrutteringSupraglottiske luftvejsanordninger | Laryseal Clear Laryngeal MaskEgypten
-
University of British ColumbiaAfsluttet
-
RWTH Aachen UniversityAfsluttetAnæstesi med brug af LMA (Laryngeal Mask Airway)Tyskland
-
Amasya UniversityAfsluttetSkjoldbruskkirurgi Intraoperativ nervevirksomhed (IONM) Gentagne laryngeal nervefunktion Dexmedetomidin vs Midazolam (anæstetiske midler)Tyrkiet (Türkiye)
-
Washington University School of MedicineTrukket tilbageLaryngeal neoplasma | Laryngeal dysplasi
-
Jagiellonian UniversityAfsluttetIntubering af Laryngeal AirwayPolen
-
Ambu A/SSahlgrenska University Hospital, Sweden; Skane University HospitalRekruttering
Kliniske forsøg med Photon Counting Computed Tomography
-
Hospices Civils de LyonRekrutteringKoronararteriesygdom | Diabetes | Ledsygdomme | Diabetisk fodsår | Interstitiel lungesygdom | Hyperaldosteronisme | Nyresten | Intrakranielle arteriovenøse misdannelser | Adrenal Incidentaloma | Parenkymatøs; Lungebetændelse | Sygdom i det indre øre | Hjerneslagtilfælde | MakroadenomFrankrig
-
Hospices Civils de LyonAfsluttet
-
Central Hospital, Nancy, FranceAfsluttet
-
Hospices Civils de LyonAfsluttetKoronar hjertesygdomFrankrig
-
Hospices Civils de LyonUkendt
-
National Institutes of Health Clinical Center (CC)AfsluttetKarsygdomme | Kræft | Metabolisk knoglesygdom | Inflammatorisk sygdomForenede Stater
-
Hospices Civils de LyonAfsluttetCochleære implantaterFrankrig
-
University of Wisconsin, MadisonAfsluttetNeuroendokrine tumorer | Somatostatin-receptor-positiv neuroendokrin tumorForenede Stater
-
Peking Union Medical College HospitalRekruttering
-
University Hospital, Strasbourg, FranceAfsluttet