- ICH GCP
- Yhdysvaltain kliinisten tutkimusten rekisteri
- Kliininen tutkimus NCT02335567
Use of in Vivo 3T MR to Characterize Carotid Plaque in Patients and Correlate MR Findings With Symptoms (3TMR)
Tutkimuksen yleiskatsaus
Yksityiskohtainen kuvaus
To utilize a 3D sequence instead of the usual 2D commonly standard industry sequence that is supplied by the various manufacturers.
Patients with greater than 50% stenosis that are 3T compatible are imaged using the two sequences to compare which sequences better visualize the plaque and it's characteristics
The purpose is to validate the ability of the new 3D sequence to detect and measure any plaque hemorrhage as well as to identify region sof Type 1 hemorrhage.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
Michigan
-
East Lansing, Michigan, Yhdysvallat, 48824
- Michigan State University - Department of Radiology
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
Hyväksyy terveitä vapaaehtoisia
Sukupuolet, jotka voivat opiskella
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Patients with 50% stenosis of the carotid arteries that are safe to undergo MRI imaging
Exclusion Criteria:
- Patients that are determined to no be safe to undergo MR imaging due to implants
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Appearance of intraplaque hemorrhage
Aikaikkuna: 1 day of scan
|
what radiologist interperts
|
1 day of scan
|
Yhteistyökumppanit ja tutkijat
Sponsori
Julkaisuja ja hyödyllisiä linkkejä
Yleiset julkaisut
- Ota H, Reeves MJ, Zhu DC, Majid A, Collar A, Yuan C, DeMarco JK. Sex differences of high-risk carotid atherosclerotic plaque with less than 50% stenosis in asymptomatic patients: an in vivo 3T MRI study. AJNR Am J Neuroradiol. 2013 May;34(5):1049-55, S1. doi: 10.3174/ajnr.A3399. Epub 2012 Nov 29.
- DeMarco JK, Willinek WA, Finn JP, Huston J 3rd. Current state-of-the-art 1.5 T and 3 T extracranial carotid contrast-enhanced magnetic resonance angiography. Neuroimaging Clin N Am. 2012 May;22(2):235-57, x. doi: 10.1016/j.nic.2012.02.007.
- Mughal MM, Khan MK, DeMarco JK, Majid A, Shamoun F, Abela GS. Symptomatic and asymptomatic carotid artery plaque. Expert Rev Cardiovasc Ther. 2011 Oct;9(10):1315-30. doi: 10.1586/erc.11.120.
- Ota H, Reeves MJ, Zhu DC, Majid A, Collar A, Yuan C, DeMarco JK. Sex differences in patients with asymptomatic carotid atherosclerotic plaque: in vivo 3.0-T magnetic resonance study. Stroke. 2010 Aug;41(8):1630-5. doi: 10.1161/STROKEAHA.110.581306. Epub 2010 Jul 8.
- Underhill HR, Hatsukami TS, Cai J, Yu W, DeMarco JK, Polissar NL, Ota H, Zhao X, Dong L, Oikawa M, Yuan C. A noninvasive imaging approach to assess plaque severity: the carotid atherosclerosis score. AJNR Am J Neuroradiol. 2010 Jun;31(6):1068-75. doi: 10.3174/ajnr.A2007. Epub 2010 Jan 21.
- DeMarco JK, Huston J 3rd. Imaging of high-risk carotid artery plaques: current status and future directions. Neurosurg Focus. 2014 Jan;36(1):E1. doi: 10.3171/2013.10.FOCUS13384.
- Zhu DC, Vu AT, Ota H, DeMarco JK. An optimized 3D spoiled gradient recalled echo pulse sequence for hemorrhage assessment using inversion recovery and multiple echoes (3D SHINE) for carotid plaque imaging. Magn Reson Med. 2010 Nov;64(5):1341-51. doi: 10.1002/mrm.22517.
- Zhu DC, Ferguson MS, DeMarco JK. An optimized 3D inversion recovery prepared fast spoiled gradient recalled sequence for carotid plaque hemorrhage imaging at 3.0 T. Magn Reson Imaging. 2008 Dec;26(10):1360-6. doi: 10.1016/j.mri.2008.05.002. Epub 2008 Jun 25.
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Arvio)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Arvio)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- GE sequence
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .