- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT01885845
Excellent BRASSS-V Drape™ Versus Indirect Measurement Protocol for Measurement of Postpartum Blood Loss
A Comparison of the Excellent BRASSS-V Drape™ and an Indirect Blood Measurement Protocol for the Measurement of Blood Loss During Third Stage of Vaginal Delivery
Postpartum hemorrhage is one of the most common causes of maternal mortality and serious maternal morbidity, especially in the developing world. In India, hemorrhage is a major cause of maternal mortality: A study by the Register General in 1993 showed that 23 percent of all maternal deaths in rural areas were caused by hemorrhage (Sibley, 2005).
The measurement of postpartum blood loss and identification of postpartum hemorrhage are important measures in efforts to prevent and treat postpartum hemorrhage. In recent years, researchers have employed several different methods to measure blood loss in hospital and community-based birth settings. Although research has demonstrated that these laboratory measures are more accurate then visual estimation techniques, no studies have explicitly documented the systematic differences (if any) among different collection modalities. Moreover, only a few of these studies have correlated measured blood loss with changes in hemoglobin levels experienced between the antepartum and postpartum period. The aim of this study is to compare variations in the measurement of blood loss obtained using two popular measurement methods: the Excellent BRASSS-V Drape™ and a modified version of the blood collection method developed by the World Health Organization (WHO).
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
Postpartum hemorrhage is one of the most common causes of maternal mortality and serious maternal morbidity, especially in the developing world. In India, hemorrhage is a major cause of maternal mortality: A study by the Register General in 1993 showed that 23 percent of all maternal deaths in rural areas were caused by hemorrhage (Sibley, 2005).
The measurement of postpartum blood loss and identification of postpartum hemorrhage are important measures in efforts to prevent and treat postpartum hemorrhage. However, visual estimation of postpartum hemorrhage often leads to underestimation of blood loss and subsequent delays in the seeking or provision of appropriate treatment. In recent years, researchers have employed several different methods to measure blood loss in hospital and community-based birth settings. Although research has demonstrated that these laboratory measures are more accurate then visual estimation techniques, no studies have explicitly documented the systematic differences (if any) among different collection modalities. Moreover, only a few of these studies have correlated measured blood loss with changes in hemoglobin levels experienced between the antepartum and postpartum period. The aim of this study is to compare variations in the measurement of blood loss obtained using two popular measurement methods: the Excellent BRASSS-V Drape™ and a modified version of the blood collection method developed by the World Health Organization (WHO).
We propose a randomized prospective study to compare the measurement of blood loss during the third stage of labor with two different methods: the modified WHO blood measurement protocol and the Excellent BRASSS-V Drape™. Upon admission in the labor ward, study staff will approach all delivering women about participation in the study and seek informed consent. Blood loss will be measured for all consenting women with vaginal deliveries.
Women who agree to participate will be randomized to one of two blood collection techniques: a modified version of the WHO blood measurement protocol or the Excellent BRASSS-V Drape™. Blood loss will be measured from immediately after delivery and cord clamping for a period of at least one hour or until active bleeding stops. The blood loss will then be quantified by the study staff and recorded on the study form. Women will receive the facility's standard care for the management of the third stage of labor and, if applicable, treatment of PPH.
Measures of postpartum hemoglobin levels will be taken at admission for delivery and twenty-four hours post-delivery for a randomly selected sub-set of study participants. Besides the measurement of blood loss and the regular measurement of hemoglobin for a sub-sample of participants, there will be no change to the hospital's standard procedures for labor and delivery.
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Pune, Inde
- KEM Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
• Vaginal birth
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Répartition: Randomisé
- Modèle interventionnel: Affectation parallèle
- Masquage: Aucun (étiquette ouverte)
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: BRASSS-V drape
Immediately after delivery and cord clamping, blood measurement will begin.
The calibrated delivery drape should be placed under the buttocks of the woman and tied around the woman's waist with the funnel portion hanging down between her legs.
Blood loss will be measured for at least one hour or, if bleeding continues after one hour, until active bleeding has stopped.
|
Immediately after delivery and cord clamping, blood measurement will begin.
The calibrated delivery drape should be placed under the buttocks of the woman and tied around the woman's waist with the funnel portion hanging down between her legs.
Blood loss will be measured for at least one hour or, if bleeding continues after one hour, until active bleeding has stopped.
|
|
Expérimental: Indirect weight method
Just after delivery and cord clamping, a sheet with plastic backing will be placed under the buttocks of the woman. A basin will be placed directly under her on a small shelf on the delivery table. Blood loss will be measured for at least one hour or, if bleeding continues after one hour, until active bleeding has stopped. After bleeding has stopped, all gauze pieces and mops will be counted and then placed in the collection basin. The basin will be placed on the scale and weighed. The weight of the blood will be assessed by subtracting the weight of the basin, gauzes and mops from the total weight of the soaked materials assuming that one gram is equivalent to 1 ml. |
Just after delivery and cord clamping, a sheet with plastic backing will be placed under the buttocks of the woman. A basin will be placed directly under her on a small shelf on the delivery table. Blood loss will be measured for at least one hour or, if bleeding continues after one hour, until active bleeding has stopped. After bleeding has stopped, all gauze pieces and mops will be counted and then placed in the collection basin. The basin will be placed on the scale and weighed. The weight of the blood will be assessed by subtracting the weight of the basin, gauzes and mops from the total weight of the soaked materials assuming that one gram is equivalent to 1 ml. |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Délai |
|---|---|
|
Mean blood loss
Délai: after delivery to when active bleeding has stopped or at least one hour
|
after delivery to when active bleeding has stopped or at least one hour
|
Collaborateurs et enquêteurs
Parrainer
Les enquêteurs
- Directeur d'études: Hillary Bracken, PhD, Gynuity Health Projects
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Estimation)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Estimation)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- 2.4.7
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .